background image

Only use this unit if it is technically in proper working order, to the intended purpose and while keeping safety and potential dan-
gers in mind.

Qualified personnel
Installation, mounting, connection, commissioning and configuration of the unit may only be carried out by qualified person-
nel. This also applies to the maintenance, testing and repair, whereat the regulations of the DIN VDE 0701 series of standards 
(repair, modification and inspection of electrical appliances) must be followed.

Regulations
The use of video and audio surveillance systems in general is strictly regulated. Inform yourself about the applicable laws and 
regulations regarding data, working and environmental protection before using the unit and ensure compliance with them.

System components
Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components can 
cause malfunctions, damages and data loss and can result in loss of warranty.

RAID System
Devices that are configured with a RAID system for redundant recording always must be supplied with power via an uninter-
ruptible power supply (UPS). A sudden voltage drop can damage the RAID system.

Modifications
Do not make any modifications to the hardware or software that has not been tested and approved by Dallmeier. Inappropri-
ate modifications can cause malfunctions, damages and data loss and can result in loss of warranty.

Documentation
Carefully and completely read the documents included in delivery. Always observe the contained instructions, notes and 
warnings.

Condensation water
If the unit is brought from a cold to a warm environment, resulting condensation water can cause malfunctions and damages. 
In this case wait (up to 8 hours) until the unit has reached room temperature before commissioning.

Operating conditions
Unfavourable operating conditions can shorten the life of the unit and can cause malfunctions, damages and data loss and 
can result in loss of warranty. Observe the specifications given in the technical data, the operating condition requirements 
and the maintenance instructions.

Shocks
Shocks can cause malfunctions and damages. The unit may not be moved while in operation.

Foreign objects
If objects or liquids get into the unit, immediately disconnect it from the power supply (pull out the power plug). Contact the 
sales partner responsible for your area.

Burnt smell
If you notice burnt smell or formation of smoke from the unit, immediately disconnect it from the power supply (pull out the 
power plug). Contact the sales partner responsible for your area.

Opening
The housing of the unit may only be opened by qualified personnel for inspection, maintenance and repair.

Disposal
Disconnect the unit from the power supply. Remove all connected devices. Return the unit to your respective sales partner.

Safety instructions

3

Saf
ety

H

DD-Moun

ting

Moun

ting

Login

C

onnec

tions

Dimensions

Summary of Contents for VideoNetBox

Page 1: ...Dallmeier VideoNetBox VideoNetBox Bank Commissioning 000791 Rev 1 1 0 English ...

Page 2: ...nnections 6 Login 8 Dimensions 10 Validity This documentation applies to the audio and video server VideoNetBox and VideoNetBox Bank It has been produced on basis of software version 7 1 1 SP Y Observe the corresponding documentation Requirements for the VideoNetBox Bank in addition Contents ...

Page 3: ...ctions damages and data loss and can result in loss of warranty Documentation Carefully and completely read the documents included in delivery Always observe the contained instructions notes and warnings Condensation water If the unit is brought from a cold to a warm environment resulting condensation water can cause malfunctions and damages In this case wait up to 8 hours until the unit has reach...

Page 4: ...onnect the designated connection cable to the HDD1 Proceed as described in order to mount the second HDD if necessary Requirements Recorders that have been ordered with hard disk drive can directly be mounted connected and commissioned Recorders that have been ordered without hard disk drive must be equipped with one 2 5 hard disk drive at least Note that all mounted hard disk drives must be teste...

Page 5: ...4 holes appropriate for the designated anchors screws Use proper anchors appropriate for the condition of the mounting site Insert the anchors into the 4 drilled holes Mount the recorder with 4 screws Connect the recorder as described on the following pages Commission the recorder as described on the following pages Ensure proper ambient conditions Ensure a stable mounting surface Ensure a horizon...

Page 6: ... D Status LED Power Q Video OUT VGA Blue The recorder is in operation Mini D SUB 15 pole VGA 1024 x 768 only configuration no video E Status LED Record R Video OUT CVBS 1 Green The recorder is recording BNC 75 Ohm 1 Vpp CVBS video analogue cameras no configuration F Status LED Alarm S Video OUT CVBS 2 Orange The recorder is in alarm state BNC 75 Ohm 1 Vpp CVBS video analogue cameras no configurati...

Page 7: ...ator 1 2 Contact IN H and I Pin Assignment Function 3 Contact 1 Camera 1 Start recording 4 Contact 2 Camera 2 Start recording 5 Contact 3 Camera 3 Start recording 6 Contact 4 Camera 4 Start recording 7 Contact 5 Camera 5 Start recording 8 Contact 6 Camera 6 Start recording 9 Contact 7 Camera 7 Start recording 10 Contact 8 Camera 8 Start recording 11 Contact 9 Global 1 Shutdown recorder 12 Contact ...

Page 8: ... of the passwords and of the network parameters is necessary for remote access e g Dallmeier PView 7 Left click the background The Recorder login dialogue is displayed Commissioning Connect the recorder and relevant peripherals to the voltage supply Ensure that the VGA monitor and a mouse are connected to the recorder Switch on the VGA monitor the peripherals and the recorder The recorder is avail...

Page 9: ...gin Password Serial number e g DAE 12345678 Note that the definition of the passwords and of the network parameters is necessary for remote access e g Dallmeier PView 7 Login Note the documentation Installation and Operation NetConfig 2 Start the software NetConfig 2 The Login dialogue is displayed Observe the appropriate Configuration documentation Set Group login as Mode Enter 192 168 2 230 as I...

Page 10: ...95 280 230 150 256 100 Measures in millimetre mm 10 www dallmeier com Dimensions ...

Page 11: ...11 Notes Safety HDD Mounting Mounting Login Connections Dimensions ...

Page 12: ... the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor de fects of the product or documentation e g print or spelling errors and for those not caused by intention or gross negligence of the manufacturer Dallmeier electronic GmbH Co KG Cranachweg 1 9305...