Connections
Voltage supply
12 V DC ±5%
Power consumption
Max. 80 W*
)
Thermal output
Max. 273 BTU/h
Temperature
+ 5°C up to +40°C (41°F − 104°F) (+20°C up to +25°C (68°F − 77°F) recommended)
The following illustrati on shows hardware with opti onal components (full range of equipment).
A
Power Supply 12 V DC
ODU socket, 2-pole, 12 V DC ±5%
N
Not Active
3.5 mm phone jack
(optional, only with Analog Upgrade Kit)
B
12 V DC OUT
Weidmüller socket, 2 pins, 12 V DC ± 5% (max. 3
.
2 A)
O
Not Active
3.5 mm phone jack
(optional, only with Analog Upgrade Kit)
C
Fuse for 12 V DC OUT
5 × 20 mm, type F, 3.15 A
P
USB Interface
4
×
USB 2.0, type A
D
Serial Interface COM 1
D-SUB, 9 pins, 1
×
RS23
2
Q
Serial Interface COM 2
2 pins on Weidmüller 20 pins, 1
×
RS485 Half Duplex
(for Dallmeier PTZ dome)
E
Video OUT Mini-D-SUB
Mini-D-SUB, 15-pole, 1920 × 1080
(for configuration, LocalViewing optional)
R
Relay OUT (1 and 2)
Weidmüller socket, 4 pins, max. 12 V DC / 24 V AC / 0.5 A,
150 mOhm
F
Audio OUT
3.5 mm phone jack, 1 kOhm, 2.828 V
pp
(optional, for intercom)
S
Contact IN global (1 - 4)
Weidmüller socket, 4 pins, only for switch / push button
(dry contact)
G
AUX / Line IN
3.5 mm phone jack, 16 kOhm, 2.828 V
pp
(optional, for intercom)
T
Contact IN cameras (1 - 8)
Weidmüller socket, 8 pins, only for switch / push button
(dry contact)
H
Video OUT HDMI
HDMI 1.3, type A, 1920
×
1080
(for configuration, LocalViewing optional)
U
Audio IN (1 - 8)
D-SUB, 15-pole, 1 kOhm, 2.828 V
pp
, D-SUB / Cinch adapter
(optional, only with Analog Upgrade Kit)
I
Video OUT BNC 1
BNC/CVBS, 75 Ohm, 1 V
pp
(optional, only with Analog Upgrade Kit)
V
Status LED (Power)
Blue / The device is in operation.
J
Video OUT BNC 2
BNC/CVBS, 75 Ohm, 1 V
pp
(optional, only with Analog Upgrade Kit)
W
Status LED (Record)
Green / The device is recording.
K
Ethernet Interface 2
RJ45, 10/100/1000 Mbps
(optional, for ViProxy)
X
Status LED (Alarm)
Orange / The device is in alarm mode.
L
Ethernet Interface 1
RJ45, 10/100/1000 Mbps
Y
Status LED (Error)
Red / The device indicates an error.
M
Video IN (1 - 8)
D-SUB, 15-pole, 1 kOhm, 2.828 V
pp
(optional, for D-SUB / BNC adapter cable)
A B C D E F G H I J K L M N O P Q R S T U V W X Y
*
)
The PSU must be able to supply at least 120 W, if the 12 V DC OUT socket is in use.
8
www.dallmeier.com