background image

  Use the drilling template or the housing feet 

 

as guidance.

 

Mark 4 drill holes.

  Drill 4 holes, appropriate for the designated 

 

anchors / screws.

  Use proper anchors, appropriate for the condition 

 

of the mounting surface.

 

Mount the appliance with 4 screws.

 

Connect the appliance as described on the 

following pages.

 

Commission the appliance as described on the 

following pages.

 

Ensure a stable mounting surface.

 

Ensure a horizontal or vertical mounting surface.

  Ensure 10 cm (4.0'') of free space at the left and 

 

right side.

The VideoNetBox II is designed for vertical mounting on a wall. As an option it can be mounted on an horizontal surface or on a 

ceiling.

Mounting

6

 www.dallmeier.com

 

Summary of Contents for SMAVIA appliance VideoNetBox II

Page 1: ...PRELOADED English Commissioning 004707 Rev 1 0 2 2014 03 13 Appliance VideoNetBox II...

Page 2: ...d result in minor or moderate injury Notice NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations Intended use The VideoNetBox II is a compact applian...

Page 3: ...hours until the device has reached room temperature before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection a...

Page 4: ...n a computer room as defined in the US fire protection regulation Standard for Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Secured room Risk of manipulation and sabotage A...

Page 5: ...nnect the HDD 1 to the designated connection cable Insert the HDD 1 completely into the guidances of the HDD slot 1 Proceed as described in order to mount the HDD 2 if necessary Finally put the cover...

Page 6: ...h 4 screws Connect the appliance as described on the following pages Commission the appliance as described on the following pages Ensure a stable mounting surface Ensure a horizontal or vertical mount...

Page 7: ...3 6 5 9 without feet 280 100 150 mm 11 0 3 9 5 9 with feet 150 mm 5 9 230 mm 9 0 95 mm 3 6 280 mm 11 0 256 mm 10 1 100 mm 3 9 4 mm 0 2 Dimensions www dallmeier com 7 HDD Mounting Safety Requirements L...

Page 8: ...r intercom S Contact IN global 1 4 Weidm ller socket 4 pins only for switch push button dry contact G AUX Line IN 3 5 mm phone jack 16 kOhm 2 828 Vpp optional for intercom T Contact IN cameras 1 8 Wei...

Page 9: ...recording 5 Contact 3 Camera 3 Start recording 6 Contact 4 Camera 4 Start recording 7 Contact 5 Camera 5 Start recording 8 Contact 6 Camera 6 Start recording 9 Contact 7 Camera 7 Start recording 10 Co...

Page 10: ...er the start is complete Login In the initial state it is possible to login without a password The rights of the Administrator group are valid Note that the definition of the passwords and of the netw...

Page 11: ...or group are valid Note that the definition of the passwords and of the network parameters is necessary for remote access SMAVIA Viewing Client Observe the documentation Operation for the software PSe...

Page 12: ...e event of the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising...