background image

Validity

This documents applies to the SMAVIA appliance VideoNetBox II. It has been created in connection with version 8.11.3 of the 
software SMAVIA Recording Server.

Documentation

•  Data Sheet - information on technical specifications and features (for trained system integrators)
•  Commissioning - instructions for mounting and commissioning (for trained system integrators)
•  Configuration - instructions for the configuration of the software (for trained system integrators)
•  Main Functions - instructions for the operation of basic software functions (for operators without special knowledge)
•  Operation - instructions for the operation of all software functions  (for operators without special knowledge)
•  Service - instructions for maintaining and cleaning (for trained system integrators)

Conventions

•  Instructions are indicated with this arrow 

.

•  Expressions in 

bold / italics

 indicate an element of the user interface.

•  Paragraphs in

 italics

 contain additional information and general recommendations.

 

Warning

WARNING indicates a hazardous situation which, if not avoided, could result in death or 

serious injury.

 

Caution

CAUTION indicates a hazardous situation which, if not avoided, could result in minor or 

moderate injury.

Notice

NOTICE indicates practices for preventing property damage, incorrect configurations or 

faulty operations.

Intended use

The VideoNetBox II is a compact appliance with a processing capacity for up to 8 IP video channels. The basic version with 2 IP 

video channels can be expanded with up to 6 additional video channels using a license code. It is perfectly suited for indoor wall 
mountings. Its compact and robust design allows for a flexible use.

Scope of delivery

Included in the scope of delivery is:

1× VideoNetBox II corresponding to the ordered equipment
1× Power Supply Unit 120 W
1× Set with all necessary screws, dowels, plugs and sockets
1× Documentation “Commissioning” published in print and on DVD-ROM
1× Documentation in accordance with the above list published on DVD-ROM

The scope of delivery may differ depending on the ordered equipment, device variant or country of destination.

Transportation and Packaging

Store the original packaging for later transportation. If the original packaging is no longer available, ensure that the used packaging 

sufficiently protects against damage, moisture, heat and cold.

Dallmeier electronic accepts no responsibility for any damage during improper transportation.

Warranty

The terms and conditions valid at time the contract was signed shall apply.

General

 

2

 www.dallmeier.com

 

Summary of Contents for SMAVIA appliance VideoNetBox II

Page 1: ...PRELOADED English Commissioning 004707 Rev 1 0 2 2014 03 13 Appliance VideoNetBox II...

Page 2: ...d result in minor or moderate injury Notice NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations Intended use The VideoNetBox II is a compact applian...

Page 3: ...hours until the device has reached room temperature before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection a...

Page 4: ...n a computer room as defined in the US fire protection regulation Standard for Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Secured room Risk of manipulation and sabotage A...

Page 5: ...nnect the HDD 1 to the designated connection cable Insert the HDD 1 completely into the guidances of the HDD slot 1 Proceed as described in order to mount the HDD 2 if necessary Finally put the cover...

Page 6: ...h 4 screws Connect the appliance as described on the following pages Commission the appliance as described on the following pages Ensure a stable mounting surface Ensure a horizontal or vertical mount...

Page 7: ...3 6 5 9 without feet 280 100 150 mm 11 0 3 9 5 9 with feet 150 mm 5 9 230 mm 9 0 95 mm 3 6 280 mm 11 0 256 mm 10 1 100 mm 3 9 4 mm 0 2 Dimensions www dallmeier com 7 HDD Mounting Safety Requirements L...

Page 8: ...r intercom S Contact IN global 1 4 Weidm ller socket 4 pins only for switch push button dry contact G AUX Line IN 3 5 mm phone jack 16 kOhm 2 828 Vpp optional for intercom T Contact IN cameras 1 8 Wei...

Page 9: ...recording 5 Contact 3 Camera 3 Start recording 6 Contact 4 Camera 4 Start recording 7 Contact 5 Camera 5 Start recording 8 Contact 6 Camera 6 Start recording 9 Contact 7 Camera 7 Start recording 10 Co...

Page 10: ...er the start is complete Login In the initial state it is possible to login without a password The rights of the Administrator group are valid Note that the definition of the passwords and of the netw...

Page 11: ...or group are valid Note that the definition of the passwords and of the network parameters is necessary for remote access SMAVIA Viewing Client Observe the documentation Operation for the software PSe...

Page 12: ...e event of the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising...

Reviews: