![dallmeier Mountera Box with PSU Commissioning Download Page 51](http://html1.mh-extra.com/html/dallmeier/mountera-box-with-psu/mountera-box-with-psu_commissioning_3321071051.webp)
51
COMMISSIONING – Mountera® Box | REV. 1.0.1 | © 2020 Dallmeier
Earthing/grounding cable of Panomera® system or camera
Safety cable of Panomera® system or camera
Earthing/grounding cable coming from the main earthing terminal
NOTICE
Damage to the Mountera® Box and the connected peripheral equipment or
serious malfunctions due to the lack of or improper earthing/grounding
Damage to electronic components caused by lightning strikes or over-volt-
ages (electrical surges) as well as malfunctions due to electromagnetic
interferences (EMI)
➡
Before connecting your Panomera® system or camera, make sure that
you have established a standard-compliant earthing/grounding system
and a correct equipotential bonding (observe the currently applicable
DIN, VDE and ISO standards as well as the locally applicable regulations
regarding the required minimum cross-sections for the earthing/
grounding cables used).
➡
Connect the earthing/grounding cable
A
and the safety cable
B
(secondary safety component) of your Panomera® system or camera
to the provided connection points on the outside of the Mountera®
Box as illustrated in Fig. 30.
➡
Mount your Mountera® bracket with Quick-Lock System and your
Panomera® system or camera to the Mountera® Box (follow the
instructions in the separately available documentations for the indi-
vidual products).
➡
Connect the Ethernet cable and the power supply cable of the
Mountera® Cable Set C to your Panomera® system or camera.
➡
Switch on the main circuit breaker of your electrical panel (fuse box)
or the individual breaker that controls the electrical circuit for your
Mountera® Box.
Summary of Contents for Mountera Box with PSU
Page 1: ...007806 REV 1 0 1 2020 01 24 COMMISSIONING Mountera Box...
Page 26: ...26 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Fig 7 Open the front cover...
Page 50: ...50 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Fig 30...
Page 61: ...61 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier 203mm 8 0 220 mm 8 7 157mm 6 2 Fig 38...
Page 62: ......
Page 63: ......