background image

007806 | REV. 1.0.1 | 2020-01-24

COMMISSIONING

Mountera® Box

Summary of Contents for Mountera Box with PSU

Page 1: ...007806 REV 1 0 1 2020 01 24 COMMISSIONING Mountera Box...

Page 2: ...Figures in this document may differ from the actual product Specifications subject to change without notice Errors and misprints excepted All trademarks identified by are registered trademarks of Dal...

Page 3: ...tions 8 5 Safety Instructions 9 6 General Notes 12 Scope of Delivery 12 Transportation and Packaging 12 Warranty 13 Appropriate Use 13 7 Requirements 14 Ambient Conditions 14 Earthing Grounding 15 Pow...

Page 4: ...actual product 2 Documents The product documentation for the device consists of various documents which are provided in printed and or digital form as for example via the website www dallmeier com Re...

Page 5: ...cification The product specification contains detailed technical data features and characteristics of the individual device The target audience of the document is trained system integrators installa t...

Page 6: ...eath or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided...

Page 7: ...structions one after the other in the sequence de scribed Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections interfaces etc...

Page 8: ...ce pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipmen...

Page 9: ...electrical appliances Periodic inspection on electrical appliances General requirements for electrical safety Regulations The use of video and audio security surveillance systems is in general strictl...

Page 10: ...for the latest product documentation updates Condensation If the device is brought from a cold to a warm environment resulting condensation may cause malfunctions and damage In this case wait until th...

Page 11: ...evice If objectsorliquidsget into the device immediately interrupt the mains voltage to the device e g switch off the corresponding circuit breaker Contact the sales partner responsible for your area...

Page 12: ...1 5 to 2 5mm 1 Insulated spade connector fork ring crimp terminal suitable for wire cross sections from 4 to 6mm 1 Time lag slow blow fuse T4A 250V AC glass tube 5 L20mm 1 Mountera Ceiling Bracket Box...

Page 13: ...suitable for 24 7 365 continuous operation both indoors and outdoors The chromated surface of the junction box is finished with powder coating in signal white RAL 9003 which has been tested for seawat...

Page 14: ...of time high heat radiation e g generated by a radiator unfavorable ambient temperatures nearby strong radiation sources e g radio transmitters magnetic fields corrosive gases and liquids or insuffic...

Page 15: ...rotective measures for a standard compliant earthing grounding and a correct lightning protection equipotential bonding of the Mountera Box and all connected peripheral equipment in accor dance with t...

Page 16: ...he product rating plates of your equipment WARNING Electrical shock caused by exposed live electrical parts as well as due to the lack of or improper earthing grounding Risk of death or serious injury...

Page 17: ...ified personnel and in compliance with the locally applicable regula tions regional and country specific legal requirements and standards such as the DIN VDE 0701 0702 series of standards VDE 0701 070...

Page 18: ...truction material of the supporting element such as for example Plastic screw anchors for use in solid masonry materials concrete brick Gravity or spring toggle anchors for use in drywall systems plas...

Page 19: ...rill hole locations through the drilling template Drilling machine with drill bit nominal drill bit diameter 8mm type of drill bit suitable for the respective construction material Foam pad with self...

Page 20: ...he supplied mounting screws anchors prepare a drill bit for the anchor size 8mm L100mm Mark the drill hole locations on the ceiling wall use the supplied drilling template if necessary At the marked l...

Page 21: ...era Box REV 1 0 1 2020 Dallmeier Remove the paper backing from the self adhesive foam pad Adhere the foam pad onto the rear side of the Mountera Box while ensuring that the foam pad is aligned as illu...

Page 22: ...x REV 1 0 1 2020 Dallmeier Fig 3 The foam pad compensates for small gaps between the device and the supporting structure that may result from manufacturing tolerances of the device or uneven textured...

Page 23: ...23 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Loosen the 4 screws of the front lid in counterclockwise direction using the supplied hexagon socket screw key size 5 Fig 4...

Page 24: ...24 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Remove the front lid from the front cover Place the front lid back into the original packaging of the device for later reuse Fig 5...

Page 25: ...25 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Loosen the 4 screws of the front cover in counterclockwise direction using the supplied hexagon socket screw key size 5 Fig 6...

Page 26: ...26 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Fig 7 Open the front cover...

Page 27: ...PORTANT Observe the safety instructions regarding the use of suitable mounting screws anchors on page 18 Mount the housing body of the Mountera Box on the ceiling wall using the 4 supplied plastic fra...

Page 28: ...28 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Fig 9 Carefully drive the 4 plastic frame anchors with hexagon head screw into the ceiling wall using a rubber mallet as illustrated in Fig 9...

Page 29: ...2020 Dallmeier Fig 10 Tighten the 4 mounting screws in clockwise direction using a ratch eting wrench handle with extension and 6 point socket drive style external hex size 10mm until the Mountera Bo...

Page 30: ...IONING Mountera Box REV 1 0 1 2020 Dallmeier 1 2 Unscrew the polyamide locknut 1 of the factory pre assembled cable entry plate in counterclockwise direction Remove the sealing plate with threaded rin...

Page 31: ...tera Box REV 1 0 1 2020 Dallmeier Fig 12 Mountera Cable Set C optionally available Unscrew the polyamide locknut counterclockwise from the sealing plate of the optionally available Mountera Cable Set...

Page 32: ...tera Box REV 1 0 1 2020 Dallmeier Feed the Mountera Cable Set C cables through the circular opening in the front cover as illustrated in Fig 13 Insert the sealing plate with threaded ring into the cir...

Page 33: ...33 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Feed the cables through the locknut Screw the locknut back onto the threaded ring of the sealing plate Fig 14...

Page 34: ...34 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Earthing Grounding Cable glands see page 56 Power Out LAN Power In Fig 15...

Page 35: ...e page 38 3 Connect the required Ethernet cables to the LAN terminal inside the Mountera Box see page 40 or page 42 4 Connect your 3 conductor mains cable to the Power In terminal inside the Mountera...

Page 36: ...ING Mountera Box REV 1 0 1 2020 Dallmeier Fig 16 Internal earthing grounding connection point Pre installed earthing grounding cable housing front cover Earthing grounding cable coming from main earth...

Page 37: ...components caused by lightning strikes or over volt ages electrical surges as well as malfunctions due to electromagnetic interferences EMI Make sure that the pre installed earthing grounding cable A...

Page 38: ...s or serious malfunctions Observe the numbers 1 4 printed on the wires of the optionally available Mountera Cable Set C before connecting the power supply cable of your Panomera system or camera to th...

Page 39: ...2020 Dallmeier Fig 19 In the figure above the wiring incl earthing grounding connection of a Panomera W8 Ultraline and its built in heater using the 5 core power supply cable of the optionally availa...

Page 40: ...x REV 1 0 1 2020 Dallmeier Fig 20 LAN terminal Mountera Box with PSU Ethernet cable of Panomera system or camera Mountera Cable Set C Ethernet cable of existing LAN shielded RJ45 patch cable CAT 6 or...

Page 41: ...thernet cable of your Panomera system or camera Mountera Cable Set C to the left socket of the shielded CAT 6A RJ45 coupler labeled with Cam as illustrated in Fig 21 Connect the Ethernet cable of your...

Page 42: ...Box with SRS Edge Fig 22 LAN terminal Mountera Box with SRS Edge Ethernet cable of Panomera system or camera Mountera Cable Set C Ethernet cable of existing LAN shielded RJ45 patch cable CAT 6 or high...

Page 43: ...e Ethernet cable of your Panomera system or camera Mountera Cable Set C to the free socket of the shielded CAT 6A RJ45 coupler labeled with Cam as illustrated in Fig 23 Connect the Ethernet cable of y...

Page 44: ...e screw of the electrical shock protection cover in counter clockwise direction using the supplied hexagon socket screw key size 2 5 The electrical shock protection cover of the Power In terminal is m...

Page 45: ...0 1 2020 Dallmeier Fig 25 Electrical shock protection cover opened Open the electrical shock protection cover Carefully lift the strain relief clamp out of the cable strain relief plate using a small...

Page 46: ...he AC input terminal labeled with the Protective Earth symbol Then connect the AC live wire phase conductor to the AC input terminal labeled with L live wire Finally connect the AC neutral wire return...

Page 47: ...e sure your mains cable is properly routed through the strain relief plate as illustrated in Fig 27 Reassemble the strain relief clamp to securely fix the mains cable Make sure the conductors of your...

Page 48: ...s Risk of death or serious injury Close the electrical shock protection cover of the Power In terminal after wiring to ensure protection against unintentional direct contact with hazardous live parts...

Page 49: ...49 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Close the front cover Tighten the 4 screws of the front cover in clockwise direction using the supplied hexagon socket screw key size 5 Fig 29...

Page 50: ...50 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier Fig 30...

Page 51: ...nding observe the currently applicable DIN VDE and ISO standards as well as the locally applicable regulations regarding the required minimum cross sections for the earthing grounding cables used Conn...

Page 52: ...0 1 2020 Dallmeier 10 Parts Description Input Fuse F1 Time lag slow blow fuse T4A 250V AC glass tube 5 L20mm Fig 31 Power In terminal fuse holder with screw cap Input fuse F1 A suitable spare fuse is...

Page 53: ...l Earthing Grounding Connections The earthing grounding cable coming from your main earthing terminal can be connected either to the earthing grounding connection point inside the enclosure as illustr...

Page 54: ...he device is equipped with a pressure equalization element M12 1 5 inside the housing Pressure equalization elements are used to prevent the formation of condensation in highly sealed enclosures where...

Page 55: ...CE Damage to the Mountera Box caused by condensation inside the housing Damage to electronic components or serious malfunctions Be careful not to cover the pressure equalization opening located on the...

Page 56: ...M20 1 5 sealing ring Fig 35 Mountera Box bottom rear view w o foam pad The pre installed cable glands are equipped with reducing sealing inserts for smaller cable diameters Unused cable entry openings...

Page 57: ...ntera Box REV 1 0 1 2020 Dallmeier Fig 36 Alternative cable entry openings M25 1 5 on top and rear side Threaded blanking plug M25 1 5 with O ring Threaded blanking plug M25 1 5 with O ring Alternativ...

Page 58: ...w fuse T4A 250V AC glass tube 5 L20mm Power outputs Max 4 Power output voltage 48V DC Output current 5 4A Total output power 260W Electrical Data SMAVIA Recording Server Appliance Voltage supply 48V D...

Page 59: ...uitable installation sites Indoor and outdoor Operating temperature 30 C to 60 C 22 F to 140 F Relative humidity 0 90 RH non condensing Approvals Certifications Type CE DIN EN 50130 4 compliant The te...

Page 60: ...60 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier 12 Dimensions Fig 37 255mm 10 0 121 mm 4 8 388 mm 15 3 347 mm 13 7...

Page 61: ...61 COMMISSIONING Mountera Box REV 1 0 1 2020 Dallmeier 203mm 8 0 220 mm 8 7 157mm 6 2 Fig 38...

Page 62: ......

Page 63: ......

Page 64: ...HEADQUARTERS Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany tel 49 941 8700 0 fax 49 941 8700 180 mail info dallmeier com www dallmeier com...