background image

www.dallmeier.com 

27

Commissioning DDF5(X)00HDV-DN-IM

 

Tighten the M4 locking screw of both ceiling clamps with a Phillips screw

-

driver until the housing is securely fixed.

Locked ceiling clamp (2×)

Summary of Contents for DDF5 00HDV-DN-IM Series

Page 1: ...005316 1 0 5 2018 12 19 IM DDF5 X 00HDV DN Commissioning English...

Page 2: ...oogle Chrome of Google Inc headquartered in Mountain View California USA HDMI of HDMI Licensing LLC headquartered in Sunnyvale California USA JavaScript of Oracle Corporation and or its affiliates hea...

Page 3: ...ty Instructions 8 5 General Notes 11 Scope of Delivery 11 Transportation and Packaging 11 Warranty 12 Approvals Certifications 12 Appropriate Use 12 Operation 13 6 Requirements 14 Ambient Conditions 1...

Page 4: ...ich are included in the scope of delivery in a printed form and or on a digital medium Read all documents included in the scope of delivery carefully and thoroughly before using the device Always foll...

Page 5: ...tes The target audience of this document is trained system integrators Other Applicable Documents Data Sheet The document Data Sheet contains detailed technical specifications features and characteris...

Page 6: ...ANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious...

Page 7: ...ons are indicated by arrows Always carry out instructions one after the other in the sequence described Expressions in quotation marks generally indicate a control element on the device switches or la...

Page 8: ...al appliances must be followed Regulations The use of video and audio surveillance systems is in general strictly regulated Inform yourself about the currently valid laws and regulations regarding dat...

Page 9: ...ioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection against over voltages as well as for the immunity of infor mation a...

Page 10: ...t from the power supply pull out the power plug Contact the sales partner responsible for your area Burnt Smell If you notice burnt smell or a formation of smoke coming from the device im mediately di...

Page 11: ...d equipment or device variant and may differ from this document s content Certain functions and features may require the purchase of an additional license Transportation and Packaging Store the origin...

Page 12: ...n the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may...

Page 13: ...t damage to the device a galvanic isolator balun must be installed if the BNC interface is permanently in use If the device or the cables connected to the device are located near sources with strong r...

Page 14: ...es Do not install operate the device in places with a large amount of dust and dirt with steam or oil vapors e g kitchen with direct sunlight with strong heat emissions e g radiator with improper ambi...

Page 15: ...onnecting or disconnecting the device Over voltage electrical surge Danger of death or serious injury as well as damage to the device To ensure the safety of persons protection against dangerous conta...

Page 16: ...rve the following notes NOTICE Damage to the surface of the device Clean the housing outside with a soft dry and antistatic cloth Do not use detergents Clean the plastic bubble with water and some dis...

Page 17: ......

Page 18: ...pporting structure and the suspended ceiling or ceiling panel Always use screws suitable for your ceiling wall material Always use the correct type of anchor for your ceiling wall type Plastic screw a...

Page 19: ...www dallmeier com 19 Commissioning DDF5 X 00HDV DN IM Torx screwdriver T20 H...

Page 20: ...20 www dallmeier com DDF5 X 00HDV DN IM Commissioning Loosen the three tamper resistant torx screws Torx TR 20 of the cover ring with a torx screwdriver T20 H 3 Tamper resistant torx screw Torx TR 20...

Page 21: ...www dallmeier com 21 Commissioning DDF5 X 00HDV DN IM Remove the cover ring bubble...

Page 22: ...22 www dallmeier com DDF5 X 00HDV DN IM Commissioning Screw the M6 eye bolt onto the bottom side of the housing M6 eye bolt Ceiling clamp 2...

Page 23: ...www dallmeier com 23 Commissioning DDF5 X 00HDV DN IM Cut a circular hole 143mm into the suspended ceiling or ceiling panel Screw a ceiling hook into the supporting structure 143mm Ceiling hook...

Page 24: ...ioning Insert the housing into the circular cut out Observe the intended viewing direction and the maximum allowable pan tilt and rotation movements angle values as illustrated on page 33 before mount...

Page 25: ...www dallmeier com 25 Commissioning DDF5 X 00HDV DN IM Attach a safety wire to the M6 eye bolt use a carabiner and the ceiling hook Carabiner Safety wire...

Page 26: ...26 www dallmeier com DDF5 X 00HDV DN IM Commissioning M4 locking screw ceiling clamp Phillips screwdriver...

Page 27: ...www dallmeier com 27 Commissioning DDF5 X 00HDV DN IM Tighten the M4 locking screw of both ceiling clamps with a Phillips screw driver until the housing is securely fixed Locked ceiling clamp 2...

Page 28: ...dallmeier com DDF5 X 00HDV DN IM Commissioning Run the required cables through a PG16 cable gland and screw the PG16 cable gland in the appropriate thread on the bottom side of the housing PG16 cable...

Page 29: ...www dallmeier com 29 Commissioning DDF5 X 00HDV DN IM...

Page 30: ...30 www dallmeier com DDF5 X 00HDV DN IM Commissioning Connect the required cables to the connectors of the camera module...

Page 31: ...of the possible LAN LED states read the documentation on camera configuration Analog video preview output BNC CVBS 1 0Vp p 75 Memory card slot microSDHC Video output HDMI Micro port Type D LAN PoE RJ...

Page 32: ...32 www dallmeier com DDF5 X 00HDV DN IM Commissioning microSDHC 32GB Class 10 UHS I optional...

Page 33: ...on the factory default viewing direction as illustrated above Always loosen both knurled locking screws before rotating the lens sensor unit moderately tighten the screws by hand again when finished P...

Page 34: ...34 www dallmeier com DDF5 X 00HDV DN IM Commissioning...

Page 35: ...is equipped with a motor driven varifocal lens The focal length zoom and the focus are adjusted over the network in the WebConfig user interface of the camera more information can be found in the doc...

Page 36: ...www dallmeier com DDF5 X 00HDV DN IM Commissioning Attach the cover ring to the housing while ensuring that the ambient light sensor is not covered by the black inner dome cover Black inner dome cove...

Page 37: ...www dallmeier com 37 Commissioning DDF5 X 00HDV DN IM Tighten the three tamper resistant torx screws Torx TR 20 of the cover ring with a torx screwdriver T20 H...

Page 38: ...to comply with UL s requirements always use a UL certified Limited Power Source LPS Class 2 power supply unit when operating the device with a separate power supply unit Power IN Weidm ller male conn...

Page 39: ...p Input impedance 29k Audio Line OUT stereo Output level at 10k load max 3 11Vp p Output impedance 320 Audio Line IN stereo Line OUT stereo Tip Left channel Left channel Ring Right channel Right chann...

Page 40: ...via Power over Ethernet a PoE injec tor is additionally required To configure the device the client PC must meet the following system require ments System Requirements Operating system OS Microsoft Wi...

Page 41: ...ish a connection to the device via Ethernet if necessary contact your network administrator for more informa tion and assistance Start the web browser Enter the IP address of the device into the addre...

Page 42: ...ls of the administrator account are User name admin Password 3 NOTICE Risk of misuse by unauthorized users Change the default login credentials of the administrator ac count as soon as possible Enter...

Page 43: ......

Page 44: ...put level max 2 83Vp p Input impedance 29k Audio Line OUT stereo 1 3 5mm phone jack Output level at 10k load max 3 11Vp p Output impedance 320 Ethernet 1 RJ45 female connector 10BASE T 100BASE TX 1000...

Page 45: ...nical impacts up to 20 joules Color Black housing white cover ring Dimensions Approx 170 H135mm 6 7 H5 3 Weight Approx 1200g 2 6lb Environmental Conditions Suitable installation sites Indoor Operating...

Page 46: ...46 www dallmeier com DDF5 X 00HDV DN IM Commissioning 134 70 mm 5 30 142mm 5 59 114 60mm 4 51 170mm 6 69 60mm 2 36 14mm 0 55 62mm 2 44 28 80mm 1 13 41 50 mm 1 63 12 Dimensions...

Page 47: ......

Page 48: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com...

Reviews: