CBU-DALI-GATEWAY
Device Manual
Made in Italy
DALCNET S.r.l.
36077 Altavilla Vicentina (VI)
–
Italy
Via Lake Garda, 22
Tel. +39 0444 1836680
REv.
25/01/2023
-
Pag.
5/11
LOCAL COMMANDS FUNCTIONALITY
N.O.
P
USH
B
UTTON
6
The Casambi app allows you to program the local command with some prearranged functions.
Button No.
Function
1
Controls a luminaire
Click
Long press (>1s)
Tap to turn a luminaire on or off
–
hold to adjust
luminaire brightness
Controls an element
Click
Long press (>1s)
Tap to turn a device element on or off
–
hold to adjust
the element value
Control a group
Click
Long press (>1s)
Tap to turn a group on or off
–
hold to adjust
brightness
Control scene
Click
Long press (>1s)
Tap to turn a scene on or off
–
hold to adjust scene
brightness
Control all luminaires
Click
Long press (>1s)
Tap to turn all luminaires on or off
–
hold to adjust
brightness
Cycles scenes
Click
Long press (>1s)
Tap to cycle through the list of scenes
–
hold to adjust
current scene brightness
Active/Standby
Click
Long press (>1s)
Tap to switch between two scenes
–
hold to adjust
current scene brightness
Controls a luminaire
Click
Long press (>1s)
Tap to turn a luminaire on or off
–
hold to adjust
luminaire brightness
Controls an element
Click
Long press (>1s)
Tap to turn a device element on or off
–
hold to adjust
the element value
Control a group
Click
Long press (>1s)
Tap to turn a group on or off
–
hold to adjust
brightness
For all other functions, consult the CASAMBI APP documentation at:
https://support.casambi.com/support/home
UNPAIRING THE DEVICE FROM THE CASAMBI NETWORK
If the device is associated with a network to which you do not have the credentials and you want to associate it with a new one,
follow the settings specified in the Casambi APP in the "Nearby Devices" section. Once the decoupling function has started and the
procedure has begun, remove the mains power supply (230Vac/110Vac) of the power supply connected to the CBU-DALI-GATEWAY
and turn it back on within 1
–
2 seconds.
If you turn the power supply off and on quickly, decoupling may not occur correctly. Repeat the decoupling sequence by escalating
1 or 2 seconds more between the instant you turn off and turn the mains power to the power supply back on
7
.
If you are unable to unpair the device, associate an N.A. button to the "INPUT" input of the CBU-DALI-GATEWAY and during the
unpairing procedure, press the button.
6
By default, the button is set as "Control a lamp".
7
The discharge time of the secondary power supply depends on the construction characteristics of the power supply used.