DALCNET CBU-DALI-GATEWAY Device Manual Download Page 1

 

CBU-DALI-GATEWAY

 

 

Device Manual 

 

 

Made in Italy

 

 

DALCNET S.r.l. 

 

36077 Altavilla Vicentina (VI) 

 Italy

 

Via Lake Garda, 22

 

 

Tel. +39 0444 1836680

 

www.dalcnet.com 

 

[email protected]

 

REv. 

25/01/2023

 - 

Pag. 

1/11

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FEATURES 

 

CODALI+GATEWAY 

 

Input: DC 12-24-48 Vdc 

 

Command: CASAMBI APP 

 

Local Control programmable from CASAMBI APP: n°1 button Normally Open 

 

Casambi signal to DALI protocol converter and vice versa 

 

Possibility to control devices with DALI control via CASAMBI APP 

 

Ability to Address DALI Devices 

 

Extended temperature range 

 

100% Function Test  

 

 

 

PRODUCT DESCRIPTION 

The device receives the command signal from the Casambi APP and depending on the fixture set sends the signal in a predetermined 
sequence of DALI addresses. 
See pag.7 for the DALI Addresses map. 
 
With the "CBU DALI GATEWAY" profile, the device receives commands from an external DALI Master and sends control signals to 
the Casambi lamps of the network to which it is associated. Each Casambi lamp has a DALI address.  
In the case of Casambi Tunable White or RGB/RBGW devices, these will be recognized by the DALI Master as DALI DT8. 

PRODUCT CODE 

 
 
 
 
 
 

 

1

 DALI bus power is required 

2

 Address management (DALI version) depends on the configuration of the Casambi module. 

CODE 

Power Supply 

Command

 

incoming 

Command

 

Outgoing 

Type of Command

 

CBU-DALI-GATEWAY

1

 

12-24-48V DC 

APP CASAMBI 

DALI

2

 

N° 1 N.O. Push Button 

Summary of Contents for CBU-DALI-GATEWAY

Page 1: ...ceives the command signal from the Casambi APP and depending on the fixture set sends the signal in a predetermined sequence of DALI addresses See pag 7 for the DALI Addresses map With the CBU DALI GATEWAY profile the device receives commands from an external DALI Master and sends control signals to the Casambi lamps of the network to which it is associated Each Casambi lamp has a DALI address In ...

Page 2: ...s WWWW AUTOMATIC 25139 Fixture for checking 4 DALI addresses TW AUTOMATIC 2700 6000K 25140 Mixer hot cold color with two channels RGB AUTOMATIC 25141 Fixture RGB DT6 RGB W AUTOMATIC 25142 Fixture RGBW DT6 RGB TW AUTOMATIC 25137 Fixture RGB Tunable White DT6 WWWW GROUP 25138 Fixture for control of 4 DALI groups 8XW GROUP 25291 Fixture for control of 8 DALI groups DALI DT8 BC RGB 11121 Fixture RGB D...

Page 3: ... TECHNICAL SPECIFICATIONS CBU DALI GATEWAY Supply voltage min 10 8 Vdc max 52 8 Vdc Nominal Power4 Min Max 12V 61 mW 115 mW 24V 120 mW 176 mW 48V 230 mW 296 mW Power loss in standby mode 500mW Operating frequency5 2402 2480 MHz Maximum output power5 7dBm Storage temperature min 40 max 60 C Ambient temperature4 min 10 max 40 C IP protection class IP10 Wiring 2 5mm 2 solid 2 5mm2 stranded 30 12 AWG ...

Page 4: ...e symbol Be sure not to connect live parts to the INPUT terminals Connect the constant voltage SELV power supply to the DC IN terminal with the and symbols Make sure you are not using a power supply with a constant current output and check that the polarity of the cables is correct Connect the DALI BUS on the DALI OUT terminals Like any other product with Bluetooth control be sure not to place the...

Page 5: ...ld to adjust luminaire brightness Controls an element Click Long press 1s Tap to turn a device element on or off hold to adjust the element value Control a group Click Long press 1s Tap to turn a group on or off hold to adjust brightness For all other functions consult the CASAMBI APP documentation at https support casambi com support home UNPAIRING THE DEVICE FROM THE CASAMBI NETWORK If the devic...

Page 6: ...AY Device Manual Made in Italy DALCNET S r l 36077 Altavilla Vicentina VI Italy Via Lake Garda 22 Tel 39 0444 1836680 www dalcnet com info dalcnet com REv 25 01 2023 Pag 6 11 MECHANICAL DIMENSIONS Excluding terminals ...

Page 7: ...TIC fixtures of the CBU DALI GATEWAY automatically direct the UNADDRESSED devices connected to the DALI BUS CBU DALI GATEWAY Casambi Slider None The device appears in the Gateway section of the Casambi app DALI2 BROADCAST Casambi Slider Dimmer 0 Address Command BROADCAST Dimmer ALL W AUTOMATIC Casambi Slider Dimmer 0 Address Command A0 Dimmer 0 WWWW AUTOMATIC Casambi Slider Dimmer 0 Dimmer 1 Dimme...

Page 8: ...ture Address Command A0 Warm white A1 Cold white RGB AUTOMATIC Casambi Slider Dimmer Color Saturation Map Address Command A0 R Red A1 G Green A2 B Blue RGBW AUTOMATIC Casambi Slider Dimmer White Color Color Saturation Map Address Command A0 R Red A1 G Green A2 B Blue A3 W White RGB TW AUTOMATIC Casambi Slider Dimmer Color temperature White Color Color Saturation Map Address Command A0 R Red A1 G G...

Page 9: ...I GATEWAY send group commands The DALI devices must be previously addressed and assigned to the desired group through an external DALI master WWWW GROUP Casambi Slider Group 0 Group 1 Group 2 Group 3 Address Command G0 Group 0 G1 Group 1 G2 Group 2 G3 Group 3 8W GROUP Casambi Slider Group 0 Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Address Command G0 Group 0 G1 Group 1 G2 Group 2 G3 ...

Page 10: ... BC fixtures of the CBU DALI GATEWAY send broadcast commands to devices compliant withIEC 62386 209 Device Type 8 DALI DT8 BC TW Sliderr Casambi Dimmer Color temperature Address Command Broadcast DT8 Dimming CCT DALI DT8 BC RGB Casambi Slider Dimmer Color Saturation Map Address Command Broadcast DT8 Dimming RGB DALI DT8 BC RGBW Casambi Slider Dimmer White Color Color Saturation Map Address Command...

Page 11: ...n the case of power supplies equipped with ground terminals it is mandatory to connect ALL protective ground points PE Protection Earth to a properly and certified protection earth The connection cables between the very low voltage power source and the product must be properly dimensioned and must be insulated from any wiring or part at non SELV voltage Use double insulated cables Dimension the po...

Reviews: