FRONTFLEX
Page 16
On the FRONTFLEX, adjust the side sections with the screws (A), Fig.
7 so that the side sec-
tions and the centre section correspond/are parallel to each other (there is an adjustment
screw on each side of the centre section).
This ensures a standardised work approach on site.
Fig.
7
It is important to ensure that the side section and centre section are horizon-
tal/parallel.
The distance between the end panels of the centre section and the side section is approx.
65
cm.
Hydraulics
Mount the pressure relief valve and the changeover valve in such a way that they exert op-
timum pressure on the sides of the centre section and do not stress the bearing.
A
Approx. 65