ENGLISH
CLEANING AND MAINTENANCE
ALWAYS FOLLOW THE INSTRUCTIONS IN MAXIMUM SAFETY CONDITIONS!
Make sure the power cable's plug has been pulled out, as the generator might have been programmed to turn on.
Make sure all the parts of the generator are cold.
The ashes are completely cold.
Ensure enough ventilation in the room when cleaning the product.
Poor cleaning affects correct operation and safety!
MAINTENANCE
To ensure correct operation, the generator must undergo routine maintenance by a
qualified technician
, at least once a year.
Periodic inspection and maintenance operations must always be carried out by specialised technicians who are
authorised
and work in
accordance with current regulations and the instructions reported in this user and maintenance manual.
DAILY
Burn pot
:
Remove the burn pot from the relevant compartment and free the holes using the special poker supplied, remove the ash from the burn
pot using a vacuum cleaner. Vacuum the ash deposited in the brazier compartment and ignition plug duct cleaning.
EVERY YEAR, HAVE THE FLUE EXHAUST SYSTEM, SMOKE DUCTS AND T-SHAPED FITTINGS SUPPLIED AND
INSPECTION PLUGS CLEANED - IF THERE ARE ANY BENDS AND ANY HORIZONTAL SECTIONS!
THE CLEANING SCHEDULE FOR THE GENERATOR IS ONLY MEANT AS A GUIDE! IT DEPENDS ON THE QUALITY OF THE
PELLETS USED AND HOW OFTEN THE EQUIPMENT IS USED.
THESE STEPS MAY NEED TO BE PERFORMED MORE OFTEN.
PERIODICAL CLEANING TO BE CARRIED OUT BY THE USER
As specified in this user and maintenance manual, periodic cleaning operations must be performed with the utmost care after reading the
instructions, procedures and times reported in this user and maintenance manual.
CLEANING THE SURFACES AND COVERING
Never use abrasive or CHEMICALLY AGGRESSIVE detergents to clean!
Surfaces must be cleaned when the generator and covering are completely cold. To carry out maintenance on surfaces and metal parts, just
use a cloth dampened with water or water and neutral soap.
Failure to comply with the directions can damage the generator's surfaces and void the warranty.
CLEANING THE CERAMIC GLASS
Never use abrasive or CHEMICALLY AGGRESSIVE detergents to clean!
The ceramic glass must be cleaned only when the glass is completely cold.
To clean the ceramic glass, use a dry brush and A NEWSPAPER THAT HAS BEEN DAMPENED AND PASSED THROUGH SOME ASH. If the glass
is very dirty, only use a detergent specifically designed for ceramic glass. Spray a modest amount on a cloth and use it on the ceramic glass.
Do not spray the detergent or any other liquid directly onto the glass or gaskets!
Failure to comply with the directions can damage the surfaces of the ceramic glass and void the warranty.
CLEANING THE PELLET TANK
When the tank is completely empty, unplug the generator's power supply cable and first remove residues (dust, shavings, etc.) from the empty
tank before emptying it.
52