ENGLISH
CONTROLS PROCEDURE
�
Press key 6.
�
Proceed by pressing key 2 until
USER MENU
is displayed.
�
Confirm using key 6.
�
Press key 2 until
RESET
is displayed.
�
Press keys 4-5 to select
ON
and press key 6.
�
''DONE''
will appear on the display to confirm
EASY SET UP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change while maintaining the
quality of the pellet. Using the EASY SET UP function, it is possible to vary the calibration of the volumetric weight by increasing or decreasing
the pre-set values.
In the stove program, the values available range from “– 3” to “+ 3”; all the stoves are calibrated in production with the optimal value of 0.
Where excessive depositing on the burn pot is evident, enter the EASY SET UP program and lower the value of a unit to "- 1" then wait until the
following day and if there is no improvement decrease further to a maximum of "- 3". Where instead it is necessary to increase the calibration
of the volumetric weight of the pellet, change the default value of “0” to “+ 1, + 2 or + 3” according to requirement.
RESET
Allows the user to reset all values modifiable by the user to the default values.
EXCESSIVE DEPOSITING OF PELLET IN THE BURN POT NORMAL OPERATION
LOW DEPOSITING OF PELLET IN THE BURN POT
-3
-2
-1
0
+1
+2
+3
THIRD RANGE OF
DECREASE IF THE
FIRST TWO ARE
INSUFFICIENT
SECOND RANGE
OF DECREASE
IF THE FIRST IS
INSUFFICIENT
FIRST RANGE OF
DECREASE (TEST
FOR 1 DAY)
OPTIMAL FACTORY
VALUE
FIRST INCREASE
RANGE
SECOND INCREASE
RANGE IF THE
FIRST IS INSUFFI-
CIENT
THIRD RANGE OF
INCREASE IF THE
FIRST TWO ARE
INSUFFICIENT
SET CHRONO
This stage is used to program when the generator automatically turns on and off.
The factory setting for
SET CHRONO
is disabled on the generator.
The chrono allows the user to program 4 time spans within a day to use every day of the week.
The switch-on and switch-off time can be set in every time slot, along with the days of use of the programmed time slot and the
desired water temperature (65 - 80°C).
The setting of the current day and time is essential to ensure the chrono operates correctly.
RECOMMENDATIONS
Before using the chrono function, set the current day and time. Therefore check that the points listed in the “
Set clock
” sub-chapter have been
followed, so that the chrono function works. Aside from programming it, activate it as well.
The ignition and switch-off times must be within the arc of one day, from 0 to 24 and not over several days.
CORRECT
INCORRECT
Switch-on time 07:00
Switch-off time 18:00
Switch-on time 22:00
Switch-off time 05:00
Example:
N.B.: Where these settings do not correct pellet depositing in the burn pot, please contact your local support centre.
CONTROL PROCEDURE
�
Press the 6 key.
�
Continue pressing the 2 key until you see
USER MENU
.
�
Confirm with the 6 key.
�
Press the 2 key until you see "
EASY SET UP
".
�
Use the 4-5 keys to increase (4) or decrease (5) the load during the WORK
phase.
�
Press the 1 key several times to confirm and exit the menu.
49