MAXIMUM WATTS
AMPERES PER LINE
SYSTEM VOLTAGE
NUMBER OF POLES
WIRES + GND
TOTAL POWER REQUIREMENTS:
CIRCUIT 1
120
2
1
1920W
16A
DES
A20
DES
DES
C,P
DES
DES
XC
DES
ALL CONDUIT CONNECTIONS ARE TO BE MADE
THROUGH THE BOTTOM OF THE ENCLOSURE'S
3
4
"
MINIMUM DIAMETER CONDUIT
THIS CABLE WILL BE PRE-TERMINATED TO THE
SPEAKERS AND COILED UP INSIDE THE REAR
RIGHT SIDE OF THE CABINET WITH A 60' WHIP FOR
TERMINATION TO THE CONTROL ENCLOSURE,
CUT TO LENGTH AND USE DETAIL "A" FOR
PROPER CONNECTION
CAB1
DETAIL "B"
A-1129
SURGE SUPPRESSOR
A-1129; SURGE SUPPRESSOR IS TO BE ATTACHED
AT THE BREAKER PANEL THAT FEEDS THIS
DEDICATED OUTLET
DAKTRONICS ELECTRICAL SUBCONTRACTOR
RESPONSIBLE FOR A-1129 CONNECTION ONLY AND
USE DETAIL "B" FOR PROPER CONNECTION
TWO-WIRE
SERVICE UP TO 175 VAC
BLACK BLACK
WHITE
SIGN LOCATION DETAILS
INSTALLED BY
COMPONENT
DESCRIPTION
MANUFACTURE'S #
PROVIDED BY
COMPONENT IDENTIFICATION LEGEND
CAB1
1500HD SERIES CABINET
0A-1534-1000
DAKTRONICS
OTHERS
JB1
DANTE AUDIO FIBER BOX, ANNCR'S ROOM
0A-2392-0001
DAKTRONICS
OTHERS
JB2
CONTROL ENCLOSURE 1500HD, 120V
0A-1534-1001
DAKTRONICS
OTHERS
WIRE TAGS
DETAILS FOR WIRE TAGS
DWG-985713
DAKTRONICS
-
RED
BLK
GND
RED
BLK
DETAIL "C"
ANALOG BACKUP SWITCH TERMINATION
*DO NOT REMOVE JUMPER WIRES*
THIS SIDE
FACTORY
TERMINATED
DETAIL "E"
T-1130
ANALOG BACKUP TRANSFORMER
GND
RED
BLK
THIS SIDE
FACTORY
TERMINATED
GND
RED
BLK
ANALOG
BACKUP
FROM JB1
W-5103349
W-1489
W-1615
3
3
1
4
4
2
W-1615
SINGLE-PHASE
THREE-WIRE 120/240 VAC
BLACK
BLACK
WHITE
0A-1534-1001
NOTE:
IF OTHER SURGE SUPPRESSION IS PROTECTING THE NECESSARY
CIRCUITS, THE A-1129 IS OPTIONAL
W-1615 AUDIO COPPER CABLE TO
BE ISOLATED AND KEPT AWAY
FROM OTHER SCOREBOARD
COPPER SIGNAL/POWER CABLES
BRDSIZE
THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWING
ARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BY
ANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OF
DAKTRONICS, INC. OR ITS WHOLLY OWNED SUBSIDIARIES.
COPYRIGHT 2022 DAKTRONICS, INC. (USA)
THIRD ANGLE PROJECTION
CH
REV
TITLE:
PROJECT:
INCHES [MILLIMETERS]
DESIGN:
SCALE:
DIM UNITS:
DATE:
SHEET
DO NOT SCALE DRAWING
FUNC - TYPE - SIZE
DRAWN:
-
JOB NO.
-
SPORTSOUND SYSTEMS
SYSTEM RISER; 1500HD
TSPRACK
02 AUG 22
P1561
F 03 C
NONE
TSPRACK
5115728
03
6: AMP1 HF1- BLK A312
7: AMP2 MF2+ ORG A313
8: AMP2 MF2- BLK A313
9: AMP2 LF2+ GRN A314
10: AMP2 LF2- BLK A314
11: AMP2 LF3+ BRN A315
12: AMP2 LF3- BLK A315
THESE ARE 12AWG WIRES
1:
AMP1 LF1+ WHT A310
2: AMP1 LF1- BLK A310
3: AMP1 MF1+ RED A311
4: AMP1 MF1- BLK A311
5: AMP1 HF1+ BLU A312
REV
DATE:
BY:
01
03 OCT 22
TBS
UPDATED WATTAGE TO 1920WATTS.
REV
DATE:
BY:
02
03 NOV 22
TBS
UPDATED FIBER TERMINATIONS.
DETAIL "D"
FIBER PATCH
PANEL TERMINATION
FIBER CONNECTIONS WILL CROSSOVER FROM FPP1 TO FPP2
BLU
ORG
GRN
BRN
SLT
WHT
TOP SIDE
FACTORY
TERMINATED
FPP1
ORG
BLU
BRN
GRN
WHT
SLT
TOP SIDE
FACTORY
TERMINATED
FPP2
JB1
(1) 15AMP DUPLEX
RECEPTACLE BY CUSTOMER
MOUNT FIBER BOX WITHIN 4' OF RECEPTACLE
TO AUDIO
RACK
ANNOUNCER LOCATION DETAILS
N/R
XB
DAK
FIBER CONVERSION BOX
W-1560
W-2524
NOTE:
ROUTE ANALOG BACKUP
WIRE AS SHOWN
DOOR OPENS
APPROX
90 DEGREES
JB2
AMP CONTROL ENCLOSURE
SEE DETAIL "A"
DETAIL "A"
CONTROL ENCLOSURE
0A-1340-0327
FROM ELECTRICAL
SERVICE
HOT
LEG
ZIP
TIE
12 34 56 78 9101112
0A-1561-1200
GROUND
REV
DATE:
BY:
03
09 DEC 22
TBS
REMOVED 230V OPTIONS AND CORRECTED FIBER BOX PART
NUMBER
PPaarrtt ## -- D
DW
WG
G--0055111155772288
VVeerrssiioonn -- 0033..22
D
Deessccrriippttiioonn -- N
N C
C SSYYSSTTEEM
M R
RIISSEER
R;; 11550000H
HD
D
LLiiffeeccyyccllee SSttaattee -- FFuullll PPrroodduuccttiioonn
LLaasstt M
Mooddiiffiieedd BByy -- ttsspprraacckk
LLaasstt M
Mooddiiffiieedd -- 22002222--1122--0099
Summary of Contents for SPORTSOUND 1500HD GEN II
Page 28: ...This page intentionally left blank...
Page 30: ...This page intentionally left blank...
Page 32: ......
Page 34: ......
Page 40: ...This page intentionally left blank...