Daktronics SI-32 Display Manual Download Page 22

Version 4 Software Operation

18

Connecting Two SI-32 Units

By chaining two SI-32 units together, there is a total of 60 switches available. To operate 

correctly, the following conditions need to be observed:

1. 

The first SI-32 will control switches 1-32 and the second will control switches 33-60. 

2. 

DIP switch four will be set on one unit, so that the units can be used together.

3. 

On each SI-32, set the DIP switch for the mode of that unit. 

4. 

In most cases, the two units must be set to the same mode. Only when using toggle 

and momentary modes, can two different modes be set.

5. 

Both units cannot be used to send a switch command to the displays at the exact 

same time. 

SI-32 Setup

1. 

Connect from the computer to the first 

SI-32 at J1, RS232 IN.

2. 

Using a flipped RJ11 cable, connect 

from J3 (RS422 OUT) on the first SI-32 to 

J2 (RS422 IN) on the second SI-32.

3. 

From the second SI-32, connect to the 

display.

4. 

When chaining the SI-32 units, set DIP 

switch S4 to the “ON” position on one 

unit. 

Refer to 

Figure 24

 for the DIP switch setting.

Figure 23: 

SI-32 Connections

Figure 24: 

SI-32 Setup

Summary of Contents for SI-32

Page 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 SI 32 INTERFACE DISPLAY MANUAL P1146 28 February 2018 ED 10606 Rev 5...

Page 2: ...art of this book covered by the copyrights hereon may be reproduced or copied in any form or by any means graphic electronic or mechanical including photocopying taping or information storage and retr...

Page 3: ...tary Mode 13 BCD Mode Binary Coded Decimal 13 Connecting Two SI 32 Units 14 SI 32 Setup 14 4 Version 4 Software Operation 15 Using the Venus 1500 Version 4 Software 15 Using the Switch Interface 15 SI...

Page 4: ...ii This page intentionally left blank ii...

Page 5: ...and Reference Drawings Introduction covers the basic information needed to make the most of the rest of this manual Take time to read the entire introduction as it defines terms and explains concepts...

Page 6: ...and one movable contact When the switch is depressed the contact closes the two terminals When the switch is released the contact opens the two terminals Network A network consists of multiple displa...

Page 7: ...tronics designed Windows based software used to make and edit display messages The Venus 1500 operating Version 3 software requires Windows 98 NT 4 0 Windows 2000 or Windows XP Home Professional with...

Page 8: ...r hung from a wall nearby Refer to Figure 3 for the mounting hole configuration on the back of the interface Computer to SI 32 Connections RS232 System A RS232 system connects the SI 32 directly to th...

Page 9: ...to connect the SI 32 to the computer This provides up to 4000 feet between the SI 32 and the computer 1 Plug the serial cable s DB25 pin connector into the signal converter 2 Plug the DB9 connector in...

Page 10: ...an N connection which are connected to an internal 5V and ground respectively Note Set the DIP switch to the correct setting before powering up the switch interface The switch setting is only recogniz...

Page 11: ...o SW1 N 3 Connect the other outer N O terminal to SW2 P 4 Connect all other SPDT switches per Steps 1 through 3 Momentary Each momentary switch connects to one switch input and controls one message 1...

Page 12: ...ght switch inputs and controls 32 messages Connect the terminals of the BCD switch to SI 32 as shown in the tables and refer to Figure 9 for BCD switch wiring Tens Digit SI 8 SW1 P 4 SW2 P 2 SW3 P 1 S...

Page 13: ...al switch inputs A rotary switch can operate in either single pole or momentary mode Refer to Figure 10 1 Connect the common pin to any SW_ N 2 Connect each terminal to a SW_ P as shown below Rotary S...

Page 14: ...witch interface controlled messages must be located in a library called SWITCH and be named MSG001 through MSG032 MSG001 is the message for SW1 MSG002 is the message for SW2 etc This allows the switch...

Page 15: ...ltaneously using one SI 32 However this number is subject to the display s memory capacity and the size of the messages Refer to switch modes for exact operation If two SI 32 units are chained togethe...

Page 16: ...ssage remains displayed is determined by the hold time configured using the Venus 1500 Software When using toggle mode set all the DIP switches to the OFF position as shown in Figure 12 SPST Switch SP...

Page 17: ...ayed at a time If a number is selected that message will be continuously displayed Upon selecting a new number the previous message will be blanked on the display and the new message will be continuou...

Page 18: ...t 4 In most cases the two units must be set to the same mode Only when using toggle and momentary modes can two different modes be set 5 Both units cannot be used to send a switch command to the displ...

Page 19: ...N or STOP command to all sign addresses on the network The switch interface cannot pick individual displays to run separate messages The operator cannot run MSG001 on display 1 MSG004 on display 2 if...

Page 20: ...message remains displayed is determined by the hold time configured using the Venus 1500 Software When using toggle mode set all the DIP switches to the OFF position refer to Figure 19 SPST Switch SPS...

Page 21: ...d at a time If a number is selected that message will be continuously displayed Upon selecting a new number the previous message will be blanked on the display and the new message will be continuously...

Page 22: ...4 In most cases the two units must be set to the same mode Only when using toggle and momentary modes can two different modes be set 5 Both units cannot be used to send a switch command to the displa...

Page 23: ...interface is used in conjunction with one or more Venus 1500 controlled displays The unit has a RS232 input RS422 input and RS422 output The inputs are used for connection to a Venus 1500 Software Sys...

Page 24: ...x 1 50 deep Body Construction Material Formed aluminum Finish Flat black Temperature Range 32 130 Fahrenheit 0 55 Celsius Connectors RJ 11 jack 6 of 6 positions used for RS232 RS 11 jack 6 of 6 positi...

Page 25: ...ssage s are named corretly in the display and are located in a directory named SWITCH The message on the sign is not correct Use the Venus 1500 Software to send a new message to the sign Make sure the...

Page 26: ...Market Description Customer Service Number Department of Transportation mass transits airports parking facilities 800 833 3157 2 When the new exchange part is received mail the old part to Daktronics...

Page 27: ...not subject to exchange Daktronics offers a Repair Return Program To send a part for repair follow these steps 1 Call or fax Daktronics Customer Service Refer to the appropriate market number in the...

Page 28: ...24 This page intentionally left blank...

Page 29: ...e drawing The drawings are listed in numeric order Assembly Switch Interface 32 Input DWG 086312 System Riser Diagram Single Pole SP DWG 093476 System Riser Diagram Momentary DWG 096221 System Riser D...

Reviews: