Version 4 Software Operation
16
SI-32 Mode Setup
The SI-32 has a DIP switch to select different operating modes. The location of the DIP
switches is shown in
Unplug the SI-32 power cord before removing the panel. Set the DIP switches to the
required mode noted in
.
Toggle Mode
Toggle mode is based on the action of a switch contact closing or opening.
• If switch contact X is closed, message X
will be continuously displayed.
• If switch contact X is opened, message X
will be blanked on the display.
• If multiple switch contacts are closed, the
messages will cycle through in the same
order the switch contacts were closed.
When cycling, the time each message
remains displayed is determined by the
hold time configured using the Venus
®
1500 Software.
When using toggle mode, set all the DIP switches to the “OFF” position; refer to
SPST Switch
SPST mode will control one message per switch. When a switch is turned on, the
corresponding message will run until that switch is turned off. When multiple switches are
activated, each message will run in the same order the switches were activated until the
switches are turned off.
SPDT Switch
SPDT mode will control two messages per switch. Each switch has two “ON” settings (one
for each of two messages). When a switch is set to either “ON” position, it will run that
message until set to “OFF,” or when the adjacent message is run. Multiple messages can
be selected, but not both messages on the same switch.
Figure 18:
SI-32 DIP Switch Location
Figure 19:
SI-32 DIP Switch Settings:
Toggle Mode