Electrical Installation
13
the Signal IN terminals and can re-drive this signal to other client drivers on the Signal OUT terminals.
The maximum wire distance between the host driver and client driver is 2,000 feet.
Some multiple-module DataTime
®
displays use host/client displays, which do not contain a driver and may
use either client or host digit outputs. The DF-1012 model uses the host/client configuration.
Address Settings
The address of each driver is set using an eight-position DIP-switch
(S1), and the address is based on that driver’s position in the display
system. If a single-line display is used, the address will typically be
Address 01. This means that switch 1 is turned ON and the remaining
7 switches are in the OFF position. This is the default address set
when each display is shipped. In multiple-product displays, the
address determines which line of information is shown on the driver’s
digits. The switch is set using a binary address. Use the table and the
examples in
for setting the address.
Note:
Some older drivers set the address of each driver using an
address plug (Daktronics part # 0A-1150-0122) in J19. The address,
either using a switch or a plug, needs to be set for each driver.
OFF
ON
1 2 3 4 5 6 7 8
Address 1
OFF
ON
1 2 3 4 5 6 7 8
Address 2
OFF
ON
1 2 3 4 5 6 7 8
Address 3
OFF
ON
1 2 3 4 5 6 7 8
Address 4
Figure 13:
Common Address Settings
Binary Address Settings
Address
Switch Number
1
2
3
4
5
6
7
8
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
OFF
OFF