background image

Mechanical Installation

3

2  Mechanical Installation

Mechanical installation consists of lifting and permanently mounting the shot clocks, 

control enclosure, and remote horn enclosure. Be sure that the installation complies with 

local building codes. 

Note: 

Daktronics assumes no liability for any installation derived from the information 

provided in this manual or installations designed and installed by others.

Lifting the Display

Small Daktronics displays use two lifting straps that encircle the cabinet. It is 

recommended to use a spreader bar with the straps.

Note: 

Daktronics assumes no liability for damages resulting from incorrect setup or lifting 

methods. 

Shot Clock Mounting

Reference Drawings:

Court View, BB-2140 and BB-2141 .....................................................................

DWG-184787

Court View, BB-2150 & BB-2151 .......................................................................

DWG-1060357

BB-2140 and BB-2150 shot clocks are mounted behind and above the top center of 

the backboard with included hardware. Due to game play, these shot clocks will be 

exposed to a lot of movement and vibration. The brackets need to be designed to 

minimize vibration and shot clock movement. 
BB-2141 and BB-2151 shot clocks are mounted on the rear of the backstop, perpendicular 

to the backboard with included hardware. Refer to 

DWG-184787

 and 

DWG-1060357

 for 

the approximate location to mount both shot clocks sizes on the backstop. 

Control Enclosure Mounting

IMPORTANT:

 The control enclosure must be located within 30' (9.1 m) of the shot clock. 

Mount on the base of the backstop with four #10 self-drilling screws. Power and signal 

from the control console will be routed to the enclosure. 

Remote Horn Enclosure Mounting

Use two #10 self-drilling screws to mount the remote horn enclosure in an open location 

so that sound is able to radiate. A 20' (6.1 m) pre-attached cable is included, but this 

cable may be extended to mount the horn enclosure further away from the control 

enclosure if needed. 

Camera Mounting

Reference Drawings:

Assy; Camera Cable Holder..............................................................................

DWG-249064

If a camera is to be added (BB-2140 and BB-2150 only), camera mounts accepting 2" (51 

mm) pipe are available; only one may be used at a time. A cable tray can be used to 

route camera wiring down either side of the shot clock. Refer to 

DWG-249064

.

Note: 

Total weight of camera and mounting arm cannot exceed 50 lb (23 kg). Design 

mounting brackets to accommodate both the shot clock and the camera. 

Summary of Contents for BB-2140

Page 1: ...ronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 TRANSPARENT SHOT CLOCKS DISPLAY MANUAL P1322 ED 15168 Rev 08 12 June 2018 Models BB 2140 BB 2150 NBA only BB 2141 BB 2151 N...

Page 2: ...o part of this book covered by the copyrights hereon may be reproduced or copied in any form or by any means graphic electronic or mechanical including photocopying taping or information storage and r...

Page 3: ...tion 4 Installation Overview 4 Power 4 Grounding 4 Power On Self Test POST 4 Radio Settings 4 Signal Connection 5 Radio Control 5 Light Strips 5 4 Troubleshooting 6 Troubleshooting Table 6 Component A...

Page 4: ...This page intentionally left blank...

Page 5: ...t drop the control equipment or allow it to get wet Specifications Label Power specifications as well as serial and model number information can be found on an ID label on the display similar to the o...

Page 6: ...sole Operation Manual ED 11976 This manual is provided on a CD with the control console and it is also available online at www daktronics com manuals Specifications The chart below details all of the...

Page 7: ...ement BB 2141 and BB 2151 shot clocks are mounted on the rear of the backstop perpendicular to the backboard with included hardware Refer to DWG 184787 and DWG 1060357 for the approximate location to...

Page 8: ...ted to displays control equipment and connected peripheral equipment must be electrically grounded Only qualified individuals may perform electrical work including verification of ground resistance Da...

Page 9: ...shown in DWG 184789 and DWG 1060264 6 Connect a signal cable from the J box to the J1 J2 or J3 jack on the back of the All Sport 5000 console Also connect the Shot Clock Start Stop Switch Daktronics p...

Page 10: ...ace console if necessary Display digits do not light but console works No wired signal from control console Check that the control enclosure is receiving 120 or 240 VAC power Check that the red DS3 LE...

Page 11: ...Verify the connector on the back of the digit circuit board is secure Bad digit or driver Exchange the digit or driver with a working one of the same part to verify the problem Replace if necessary Se...

Page 12: ...Figure 4 to view the component locations within the control enclosure HAZARDOUS VOLTAGE BEFORE SERVICING DISCONNECT POWER Driver Status Indicators Shot Clock Driver Horn Interface Card Transformers F...

Page 13: ...nce Drawings Schematic Control Enclosure 120 240V AC DWG 216653 Since the same LED drivers can be used for many display models each driver must be set to receive the correct signal input or address fo...

Page 14: ...er Transparent Shot Clock 0P 1322 0006 7 Two Digit plus Tenths Dual Sided Red BB 2151 0P 1322 0007 13 7 Segment plus Tenths Dual Sided Red BB 2150 0P 1322 0008 Transformer 16 VAC T 1066 Transformer 10...

Page 15: ...______ To participate in the Exchange Program follow these steps 1 Call Daktronics Customer Service Market Description Customer Service Number Schools including community junior colleges religious org...

Page 16: ...mage during shipment Electronic components such as printed circuit boards should be placed in an antistatic bag before boxing Daktronics does not recommend using packing peanuts when shipping 4 Enclos...

Page 17: ...sure 120 240V AC DWG 216653 Mechanical Spec BB 2140 DWG 223192 Mechanical Spec BB 2141 DWG 223193 Mechanical Spec Shot Clock Control Enclosure DWG 225832 Mechanical Spec Remote Horn DWG 235683 Electri...

Page 18: ...This page intentionally left blank...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ...DATE REV BY DATE REV BY DATE REV BY DATE REV BY DATE REV BY DATE REV BY 06 19 AUG 15 ZSW PER EC 16838 INCREASED BASE WIDTH FROM 6 TO 8 INCREASED MTG HOLE SPACING FROM 4 875 TO 6 5...

Page 23: ...ESS WRITTEN CONSENT OF DAKTRONICS INC COPYRIGHT 2015 DAKTRONICS INC DAKTRONICS INC AV DRAWN DATE SHEET JOB NO REV TRANSPARENT SHOT CLOCKS MECHANICAL SPEC BB 2141 CBRECZI 02 MAR 05 P1322 E 10 A 1 15 CB...

Page 24: ......

Page 25: ......

Page 26: ...AT EXPOSED TERMINALS HAZARDOUS VOLTAGE BEFORE SERVICING DISCONNECT POWER...

Page 27: ......

Page 28: ......

Page 29: ...DATE REV BY 01 19 AUG 15 ZSW PER EC 16838 INCREASED BASE WIDTH FROM 6 TO 8 INCREASED MTG HOLE SPACING FROM 4 875 TO 6 5...

Page 30: ...DATE REV BY 01 19 AUG 15 ZSW PER EC 16838 INCREASED BASE WIDTH FROM 6 TO 8 INCREASED MTG HOLE SPACING FROM 4 875 TO 6 5...

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ...This page intentionally left blank...

Page 35: ...Daktronics Warranty Limitation of Liability 31 B Daktronics Warranty Limitation of Liability This section includes the Daktronics Warranty Limitation of Liability statement SL 02374...

Page 36: ...This page intentionally left blank...

Page 37: ...placement parts or Equipment will be new or serviceably used comparable in function and performance to the original part or Equipment and warranted for the remainder of the Warranty Period Purchasing...

Page 38: ...ectors employees or agents be liable for any claims asserting or based on a loss of use of the facility or equipment lost business revenues or profits loss of goodwill failure or increased cost of ope...

Reviews: