2
MAN #650431B
AVAILABLE SCREENS:
The following screens are ONLY available on LCD1 or LCD2 (see main VHX manual for settings):
Message displays
Default LCD
DESCRIPTION
.
ODOMETER
1
Odometer reading (0-999,999)
A MILES
1
Trip A odometer reading (0-9999.9)
B MILES
1
Trip B odometer reading (0-9999.9)
SERVIC
(when enabled)
1
Distance to next service (0-9,999, or ---- when past due)
ENGINE
1
Check Engine indicator
BRAKE
1
Brake Warning indicator
4W DRV
1
4 Wheel Drive indication
WAIT
1
Diesel Wait To Start indicator
CLOCK
2
12 hour clock display (press and hold switch to set)
HOURS
2
Hours system has been on with tach signal (0-999.9)
HI SPEED
2
High speed recall (0-255)
0-60 MPH
2
0-60 mph time in seconds (0-25.5)
1/4
¼
MI SPD
2
Vehicle speed at end of ¼ mile (trap speed)
1/4 MI TIME
2
Time to travel ¼ mile from standing start
HIGH RPM
2
High RPM recall (0-18,000)
volts
none
Battery voltage (display may be enabled in setup)
In addition to the above screens, LCD1 and LCD2 may display any or all the screens listed below. These
screens are also available for display in LCD3 and LCD4. The main VHX operations manual covers
selecting which screens display in LCD1 and LCD2. See the setup instructions in this manual for selecting
the which screens display in LCD3 and LCD4.
LCD1/LCD2/LCD3/LCD4
Message displays
DESCRIPTION
.
tachometer
Digital tach readout on message display
MPH
Digital speed readout on message display
KM/H
Digital alternate speed unit conversion
water TEMP
Digital engine temp readout on message display
OIL PRESSURE
Digital oil pressure readout on message display
FUEL
Digital fuel level readout on message display
GEAR
(with optional
GSS
)
Gear shift position indicator
Additionally, many other screens may also be available (many of these readings require additional
sensors and or BIM expansion modules) including:
Gear Position
Compass
Various temperature readings
Various pressure readings
More readings may be available from BIM modules
By default all available screens for LCD3 and LCD4
are set to “ON” but only screens with data available
will be displayed.
WARNING POINTS:
Warnings for the main system values (Engine Temp, Oil Pressure, Fuel, and Tachometer) will only be
displayed in LCD1, however, BIM modules that have the internal warning points (set in VHX main
system setup) will flash if they are currently being displayed and they are in a warning condition.