background image

MAN #650343b 

For HDX systems follow these steps: 

 

Make sure the BIM units are all connected to the gauge control box. 

 

With the ignition on, press and hold both switches to enter SETUP.  With external switches hold either one 
while turning the ignition on.  Release the switches when SETUP is shown. 

 

Press and release either switch until BIM is selected.  Press and hold either switch to enter BIM setup menu. 

 

Release the switch.  A list of the BIM’s found should be shown.  If NONE FOUND is displayed then check 
connections to the BIM-05. 

 

Press and release either switch until BIM-05 is selected. 

 

Press and hold either switch to enter setup for this module. 

 

Release the switch.  The menu will show FORMAT, LABEL, WARN LO, WARN HI, CALIBRATE, BACK.  Any 
menu that does not apply to this BIM will be grey and cannot be selected. 

 

Use either switch to select the option you wish to change, (refer to the HDX manual for specifics). 

 

When you are finished select BACK to return to the BIM selection menu. 

 

When you are finished, select BACK to return to the BIM list menu, select BACK to return to the main menu, 
and then select EXIT SETUP to return to normal operation. 

With HDX systems the setup can also be done with the Dakota Digital app for Apple and Android devices. 
 
Troubleshooting quick tips: 
While the BIM is operating, the dot in the upper left corner of the display will indicate the status.  On steady indicates it 
is powered up but not receiving any bus activity.  Flashing indicates it is communicating on the bus. 
To see the sensor and channel status on the BIM display, press and hold the switch.  The display will cycle through 
three screens.  The first will show the sensor input status.  Each digit on the display will show the status for one of the 
channels.  ‘

E

’ indicates there is a bus ID conflict on that channel ID.  ‘

-

’ indicates the sender is connected properly.  If 

the input is turned off the digit will be blank. 
The second screen will show the ID assigned to channel 1.  The third screen will show the ID assigned to channel 2.  

 

 

Troubleshooting guide. 

Problem   

 

Possible cause 

 

 

Solution   

 

 

 

 

 

Sensor does not show on 

PWR terminal does not have power. 

Connect to a location that has power. 

  gauge readout. 

 

GND terminal does not have a good 

Connect to a different ground location. 

  BIM will not light up at all. 

  ground. 

 

 

 

Module is damaged. 

 

Return for service.  (see instructions) 

 

 

 

Sensor does not show on 

Interface cable is not connected. 

Connect the supplied 3.5mm data cable between the BIM unit and  

  gauge readout. 

 

 

 

 

 

  the gauge control box. 

  BIM has a steady dot lit 

Interface cable is loose. 

 

Make sure both ends of the cable are seated in securely. 

 

 

 

On VHX systems, the BIM display  

Follow instructions in VHX manual to enable the BIM display screen. 

 

 

 

  for this channel is disabled. 

   

 

 

Another BIM is set with the same  

Test module works when connected to control box alone.  Change ID’s 

   

 

 

 channel IDs. 

 

 

  on one of the modules so each module uses unique IDs. 

 

Gauge lights up, but does 

Loose connection on sensor wires. 

Inspect and reconnect wires. 

  not read correctly.   

Connector not seated on sensor. 

Reattach the sensor plug, making sure the locking tab clicks in place. 

 

 

Channel sensor label setup is incorrect.  See “Setting sender setup” in the manual. 

 

 

 

Wrong input is being used. 

 

Use V HI for 0-50V and V LO for 0-5V. 

Voltage or wiring problem in the 

Check wiring harness for loose or damaged wires. 

 

 

 

  vehicle wiring harness. 

   

 

 

 

 

 

 

 

 

BIM display shows “

88:8

” 

Data cable is damaged. 

 

Inspect and replace 3.5mm data cable. 

 

 

 

Another module on the bus is damaged  Inspect other modules on the data bus. 

 

 

 

  or connected improperly. 

 

 

 

 

 

 

 

 

 

Summary of Contents for BIM-05-1

Page 1: ... are two interface I O ports on the module Either one can be connected to the gauge system or to another module allowing several units to be daisy chained together Do not connect the I O port to anything other than a Dakota Digital gauge or BIM Do not mount the module in the engine compartment it should be mounted in interior of the vehicle Each sensor connected to the bus needs a unique ID number...

Page 2: ...ge display Press and hold SW1 The message display should show SCAN followed by the number of BIM channels detected Release SW1 If 0 is shown check all connections and then press and hold SW1 with SCAN shown to retry reading the modules Otherwise if any other number is shown press and release SW1 until SETUP is shown Press and hold SW1 until the speed display shows or the message changes Release SW...

Page 3: ...ch digit on the display will show the status for one of the channels E indicates there is a bus ID conflict on that channel ID indicates the sender is connected properly If the input is turned off the digit will be blank The second screen will show the ID assigned to channel 1 The third screen will show the ID assigned to channel 2 Troubleshooting guide Problem Possible cause Solution _ Sensor doe...

Page 4: ...efective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or replaced at Dakota Digital s option This warranty does not cover nor extend to damage to the vehicle s systems and does not cover diagnosis removal or reinstallation of the product This Warranty does not apply to any product or part thereof which in the opinion of the ...

Reviews: