MAN #650343b 

 
 
 

BIM-05-1 

Bus Interface Module for voltage and current 

(Current sensors are sold separately) 

0

-5

 V

0

-5

0

 V

0

-5

 V

0

-5

0

 V

Connect to main 
 chassis ground

+12V  

KEY ON POWER

   (fused 5 - 20 AMP max)

setup/status switch

To gauge control box
 or another BIM

SEN-20-3

G

ro

u

n

d

P

o

w

e

r

O

u

tp

u

t

www.dakotadigital.com

605-332-6513

Device monitored by Channel 2

Device monitored by Channel 1

+12V  

KEY ON POWER

   (fused 5 - 20 AMP max)

Connect to BIM-05

 GND terminal

Connect to BIM-05 V LO input

Optional 
SEN-20-3 
for current 
monitoring
(purchased separately)

* Connect V HI or V LO, but not both.

T

o

 l

o

a

d

 t

o

 b

e

 m

o

n

it

o

re

d

V

 L

O

 #

1

V

 H

#

1

BIM-05-1

VOLT / CURRENT

V

 H

#

2

V

 L

0

 #

2

P

W

R

G

N

D

www.dakotadigital.com

[email protected]

605-332-6513

I/

O

I/

O

 

This Bus Interface Module has inputs for up to two devices to be monitored.  Each channel can be configured 
individually.  There are two interface (I/O) ports on the module.  Either one can be connected to the gauge system or to 
another module, allowing several units to be daisy chained together.  Do not connect the I/O port to anything other 
than a Dakota Digital gauge or BIM.  Do not mount the module in the engine compartment; it should be mounted in 
interior of the vehicle. 
Each sensor connected to the bus needs a unique ID number assigned to it.  This module has inputs for two channels 
so it can use one or two ID numbers.  Each of the two channels can be assigned an ID from 1 – 16, or turned off.  The 
factory default ID numbers are 3 and 4 for the two inputs respectively.  The factory default labels are VOLTS for both. 
 
Labels available for each input are: 
VOLT - 

voltage input.  This will display VOLT, V, or BIM VOLTAGE. 

CURRENT - 

SEN-20-3 sensor input.  This will display AMPS, C, or CURRENT. 

 
Specs for each input are: 
 

 

Part #   

Input 

Range     

resolution 

low warning 

high warning 

VOLT   

none 

 

V HI 

0 – 50.0 V 

0.1 

 

0 – 31    

10 – 41  

VOLT   

none 

 

V LO 

0 – 5.00 V 

0.01 

 

0 – 3.1    

1.9 – 5.0 

CURRENT 

SEN-20-3 

V LO 

0 – 250 A 

 

none 

 

5 – 320  

 

Summary of Contents for BIM-05-1

Page 1: ... are two interface I O ports on the module Either one can be connected to the gauge system or to another module allowing several units to be daisy chained together Do not connect the I O port to anything other than a Dakota Digital gauge or BIM Do not mount the module in the engine compartment it should be mounted in interior of the vehicle Each sensor connected to the bus needs a unique ID number...

Page 2: ...ge display Press and hold SW1 The message display should show SCAN followed by the number of BIM channels detected Release SW1 If 0 is shown check all connections and then press and hold SW1 with SCAN shown to retry reading the modules Otherwise if any other number is shown press and release SW1 until SETUP is shown Press and hold SW1 until the speed display shows or the message changes Release SW...

Page 3: ...ch digit on the display will show the status for one of the channels E indicates there is a bus ID conflict on that channel ID indicates the sender is connected properly If the input is turned off the digit will be blank The second screen will show the ID assigned to channel 1 The third screen will show the ID assigned to channel 2 Troubleshooting guide Problem Possible cause Solution _ Sensor doe...

Page 4: ...efective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or replaced at Dakota Digital s option This warranty does not cover nor extend to damage to the vehicle s systems and does not cover diagnosis removal or reinstallation of the product This Warranty does not apply to any product or part thereof which in the opinion of the ...

Reviews: