MAN#650504C 

Troubleshooting quick tips: 

While the BIM is operating normally, the status light will flash green.   
A steady green indicates it is powered up but not receiving any bus activity. 
A flashing yellow-red (steady red with a flashing green) indicates an open or shorted temperature sensor connection. 
A green flash-red flash indicates the BIM is currently selected in the gauge setup menu. 
A green-red-red flash indicates an ID conflict with another connected BIM. 
 
 
 

Troubleshooting guide. 

Problem   

 

Possible cause 

 

 

Solution   

 

 

 

 

 

Sensor does not show on 

PWR wire does not have power. 

Connect to a location that has power. 

  gauge readout. 

 

GND wire does not have a good 

Connect to a different ground location. 

  BIM will not light up at all. 

  ground. 

 

 

 

Power/data harness is damaged. 

Inspect harness.  Repair or replace any damaged areas. 

 

 

 

Module is damaged. 

 

Return for service.  (see instructions) 

 

 

 

Sensor does not show on 

Interface cable is not connected. 

Connect the supplied 3.5mm data cable between the module and  

  gauge readout. 

 

 

 

 

 

  the gauge control box. 

  BIM has a steady green 

Interface cable is loose. 

 

Make sure both ends of the cable are seated in securely. 

  light. 

 

 

Another BIM is set with the same  

Test module works when connected to control box alone.  Change ID 

   

 

 

 channel ID. 

 

 

  on one of the modules so each module uses unique ID. 

 

 

 

 

 

On VHX systems, the BIM display  

Follow instructions in VHX manual to enable the BIM display screen. 

 

 

 

  for this channel is disabled.   

 

 

 

 

 

 

 

  

Sensor does not show on 

Another BIM is set with the same  

Test module works when connected to control box alone.  Change ID  

  gauge readout. 

 

channel ID. 

 

 

  on one of the modules so each module uses unique ID. 

  BIM light is flashing  

 

  green-red-red.  

 

 

 

 

 

 

 

 

 

 

 

 

 

Gauge lights up, but does 

Loose connection on sensor wires. 

Inspect and reconnect wires. 

  not read correctly.   

Connector not seated on sensor. 

Reattach the sensor plug, making sure the locking tab clicks in place. 

 

 

Channel sensor label setup is incorrect.  Change label by entering BIM setup through gauge system. 

 

 

 

Voltage or wiring problem in the 

Check wiring harness for loose or damaged wires. 

 

 

 

  vehicle wiring harness. 

   

 

 

 

 

 

 

 

 

Gauge lights up, but displays  SND terminal is shorted to ground. 

Check wire for damaged insulation.  Replace if necessary. 

  

“---”.  

 

 

Sender is damaged.  

 

Replace sender. 

 

 

 

 

 

 

Gauge lights up, but displays  Sender is not connected to gauge. 

Connect SND terminal on gauge to sender terminal. 

  

“EEE”.    

 

Wire between gauge and sender is 

Test and replace wire. 

 

 

 

  broken. 

 

 

 

Sender is damaged.  

 

Replace sender. 

 

 

 

Module is damaged. 

 

Return module for service.  (see instructions) 

 

 

 

 

 
 

 

Summary of Contents for BIM-04-2

Page 1: ... to an unused value The factory default label is TEMP but this can be changed in the gauge setup Labels available for each input are TEMP generic temperature input This will display TEMP x Tx or TEMPERATURE CHx where x is a number from 1 8 corresponding to the module ID number ID s over 8 will start over at 1 WATER dual water temperature input for right hand side water temp sensor When this is act...

Page 2: ...and hold SW1 The message display will show LABEL Release SW1 The message display will show the label assigned to this channel Press and release SW1 until the desired label is shown Press and hold SW1 The message display will show WARN this is skipped if WATER was selected for the label Release SW1 The message display will show H followed by the current high warning point or will flash the warning ...

Page 3: ...BIM is set with the same Test module works when connected to control box alone Change ID channel ID on one of the modules so each module uses unique ID On VHX systems the BIM display Follow instructions in VHX manual to enable the BIM display screen for this channel is disabled Sensor does not show on Another BIM is set with the same Test module works when connected to control box alone Change ID ...

Page 4: ...efective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or replaced at Dakota Digital s option This warranty does not cover nor extend to damage to the vehicle s systems and does not cover diagnosis removal or reinstallation of the product This Warranty does not apply to any product or part thereof which in the opinion of the ...