background image

MAN#650504C 

 
To set or change the ID number: 

 

The ID will not normally need to be changed.  A green-red-red flash on the BIM-04-2 status light indicates an ID 

conflict with another connected BIM.  The following procedure will allow the BIM-04-2 to automatically select a new, 
unused ID. 

 

Hold the switch on BIM while turning the key on.  The BIM status light will be steady RED. 

 

Release the switch. 

 

When the status light begins flashing, it is finished. 

 

The labels and warning points are set up through the gauge display system. 
Only VFD3/3X controls with a plastic case support adding BIM’s. 
For VFD3, VFD3X, and VHX systems follow these steps: 

 

Make sure the BIM units are all connected to the gauge control box with the 3.5mm data cables. 

 

Hold the SW1 switch from the gauge system control box while turning the key on.  The message display should 
show SETUP. 

 

Release SW1. 

 

Press and release SW1 until BIM is shown on the message display. 

 

Press and hold SW1.  The message display should show SCAN followed by the number of BIM channels 
detected.  Release SW1. 

 

If 0 is shown, check all connections and then press and hold SW1 with SCAN shown to retry reading the modules. 

 

Otherwise, if any other number is shown, press and release SW1 until SETUP is shown. 

 

Press and hold SW1 until the speed display shows “ – ” or the message changes. 

 

Release SW1.  On the VFD3 systems the message display will show the label assigned to the first channel found 
and the speed display will show “C” followed by the channel ID number.  On the VHX systems the message 
display will show “CH” followed by the channel ID number on one line and the label currently assigned on the 
second line. 

 

Press and release SW1 until the desired channel ID number is shown. 

 

Press and hold SW1.  The message display will show “LABEL”. 

 

Release SW1.  The message display will show the label assigned to this channel. 

 

Press and release SW1 until the desired label is shown. 

 

Press and hold SW1.  The message display will show “WARN” (this is skipped if WATER was selected for the 
label). 

 

Release SW1.  The message display will show “H” followed by the current high warning point or will flash the 
warning point. 

 

Press and release SW1 to change the high warning point to the desired value. 

 

Press and hold SW1.  The message display will now show “DONE”. 

 

This can be repeated for additional channels, or the key can be turned off to exit setup. 

 
For HDX systems follow these steps: 

 

Make sure the BIM units are all connected to the gauge control box. 

 

With the ignition on, press and hold both switches to enter SETUP.  With external switches hold either one while 
turning the ignition on.  Release the switches when SETUP is shown. 

 

Press and release either switch until BIM is selected.  Press and hold either switch to enter BIM setup menu. 

 

Release the switch.  A list of the BIM’s found should be shown.  If NONE FOUND is displayed then check 
connections to the BIM-04-2. 

 

Press and release either switch until BIM-04-2 is selected.  The status LED on the BIM will flash RED-GREEN. 

 

Press and hold either switch to enter setup for this module. 

 

Release the switch.  The menu will show FORMAT, LABEL, WARN LO, WARN HI, CALIBRATE, BACK.  Any 
menu that does not apply to this BIM will be grey and cannot be selected. 

 

Use either switch to select the option you wish to change, (refer to the HDX manual for specifics).   

 

When you are finished select BACK to return to the BIM selection menu. 

 

When you are finished, select BACK to return to the BIM list menu, select BACK to return to the main menu, and 
then select EXIT SETUP to return to normal operation. 

With HDX systems the setup can also be done with the Dakota Digital app for Apple and Android devices. 

Summary of Contents for BIM-04-2

Page 1: ... to an unused value The factory default label is TEMP but this can be changed in the gauge setup Labels available for each input are TEMP generic temperature input This will display TEMP x Tx or TEMPERATURE CHx where x is a number from 1 8 corresponding to the module ID number ID s over 8 will start over at 1 WATER dual water temperature input for right hand side water temp sensor When this is act...

Page 2: ...and hold SW1 The message display will show LABEL Release SW1 The message display will show the label assigned to this channel Press and release SW1 until the desired label is shown Press and hold SW1 The message display will show WARN this is skipped if WATER was selected for the label Release SW1 The message display will show H followed by the current high warning point or will flash the warning ...

Page 3: ...BIM is set with the same Test module works when connected to control box alone Change ID channel ID on one of the modules so each module uses unique ID On VHX systems the BIM display Follow instructions in VHX manual to enable the BIM display screen for this channel is disabled Sensor does not show on Another BIM is set with the same Test module works when connected to control box alone Change ID ...

Page 4: ...efective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or replaced at Dakota Digital s option This warranty does not cover nor extend to damage to the vehicle s systems and does not cover diagnosis removal or reinstallation of the product This Warranty does not apply to any product or part thereof which in the opinion of the ...

Reviews: