ENERGISER DISPLAY Models MT5, MT15, 35 & BT12, 20

1. 

 Overload

 red LED - flashes slowly (once per pulse) when the load exceeds an acceptable level. When 

this occurs it is likely that the fence has a fault. Operating into an overload will NOT harm the MT60 / 100, 

BT50 / 80. This LED also flashes quickly to indicate a low battery or energiser error.

2.   

Energiser OK

 green LED - Flashes with each pulse to show the unit is operating correctly.

  

 .

3

KiloVolts

 display – Shows the voltage on the output terminals of the energiser. The higher the voltage 

the more effective the fence will be. 
  

 .

4

Load Factor

 display – from 0 to 10, 10 being a dead short circuit, 0 being no fence load at all. Indicates 

the fence load at the energiser. Useful for a quick check of fence health.

ERROR CODES

Battery  powered  energisers  may  see  the  red  Overload  LED  flash  twice  (2)  in  succession,  or  for  models 

featuring digital display a reading of 

Lo b,

 this means 

low battery voltage.

 (Early models will switch 

themselves off to conserve the battery on re-applying the correct voltage the energiser will start up). At this 

warning indication your battery needs to be re-charged to prevent permanent battery damage and loss of fence 

voltage.
Should the red overload LED flash 3 or more times in succession, or for models featuring digital display 

a reading 

Er 03, 04 or 05

 your energiser will require service, please return to the point of purchase for 

professional care.

ENERGISER DISPLAY MT60, 100 & BT50, 80

PAGE 4 –  DAKEN Users Manual

MT35 Energiser showing LED display

1. 

 Overload

 red LED - flashes slowly (once per pulse) when the load exceeds an acceptable level. When 

this happens it is likely that the fence has a fault. Operating into an overload will NOT harm the MT15/35, 

BT10 / 20. This LED also flashes quickly to indicate an energiser error.

2.   

Energiser OK

 green LED - Flashes with each pulse to show the unit is operating correctly.

BT80 Energiser showing LED display

Summary of Contents for Techfence BT12

Page 1: ... information FREECALL 1800 636 451 email daken nsw clarkequipment com au www daken com au INSTALLATION AND OPERATIONS MANUAL For Techfence Energiser Models Mains Powered MT5 MT15 35 60 and 100 Battery Powered Solar BT12 20 50 and 80 ...

Page 2: ...thout supervision Young children should be supervised to ensure that they do not play with the appliance SCOPE This manual is the users instruction manual for Daken Techfence energisers Models BT12 BT20 BT50 BT80 battery and solar energisers Models MT15 MT35 MT60 MT100 mains operated energisers MT5 For more information please see the DAKEN Electric Fencing Manual and Australian Standard AS3014 DAK...

Page 3: ...olar Powered Energisers 5 Earthing 5 Solar Energiser Kit Installation 6 Checking your Solar Energiser is Operating Correctly 6 Estimated State of charge of a 12V car battery 6 TROUBLE SHOOTING 7 Testing Your Fence 7 TestingThe Earth 7 Fault Finding The Fence 7 INSTRUCTIONS FOR INSTALLATION AND CONNECTION OF ELECTRIC FENCES IN AUSTRALIA AS REQUIRED UNDER AS NZS 60335 2 76 8 DEFINITIONS 8 GENERAL RE...

Page 4: ...ower the BT12 20 50 and 80 will run from a battery that is charged from a solar panel The BT12 requires a 10W panel and at least a 7Ah battery preferably 15Ah The BT20 requires a 20W panel and at least a 15Ah battery perferably 30Ah The BT50 requires a 40W panel and at least a 30Ah battery perferably 60Ah The BT80 requires a 40W panel and at least a 60Ah battery perferably 120Ah Solar regulator re...

Page 5: ...OWERED ENERGISERS Model BT12 Solar BT20 BT50 BT80 Energiser 8 5kV peak no load output voltage Pulse period 1 3 seconds normal 1 7 seconds low battery Stored Energy 1 Joule 2J 5J 8J Power 12V or 24V absolute maximum 30V 12V Drain 85mA 150mA 375mA 570mA Protection Input surge noise and over voltage protected Output surge lightning protection Solar Panel 10 Watt 20 Watt 40 Watt 40 Watt Solar Battery ...

Page 6: ...s featuring digital display a reading of Lo b this means low battery voltage Early models will switch themselves off to conserve the battery on re applying the correct voltage the energiser will start up At this warning indication your battery needs to be re charged to prevent permanent battery damage and loss of fence voltage Should the red overload LED flash 3 or more times in succession or for ...

Page 7: ...d system For detailed information on earthing see the Daken Electric Fencing Manual IMPORTANT NOTE Always ensure adequate ventilation is given to the enclosure if it houses a battery Lead Acid batteries may emit explosive gases while charging Battery Installation Attach the battery leads to the battery The red positive lead to and the black negative lead to on the battery The battery should be ins...

Page 8: ...i r e t e m t l o v e h t h t i W r o t a l u g e r e h t m o r f s e r i w l e n a p e h t t c e n n o c s i D l e n a p r a l o s e h t k c e h c o T 1 range check that the panel is delivering approximately 19V in good sunlight s d a e l r o t a l u g e r e h t t c e n n o c s i D r o t a l u g e r e h t o t n o s d a e l l e n a p r a l o s e h t e c a l p e r r o t a l u g e r e h t k c e h c ...

Page 9: ...s or 3kV Should this point be reached you will need to trouble shoot your fence to determine the presence of short circuits or high load from weed growth See Fault finding the fence on page 7 for assistance or see the Daken Fencing Manual TESTING THE EARTH This requires a Daken Fence Tester or Daken Fault Finder For detailed information on earthing see the Daken Electric Fencing Manual FAULT FINDIN...

Page 10: ...r persons shall be avoided 3 An electric fence shall not be supplied from two different energisers or from independent fence circuits of the same energiser For any two different electric fences each supplied from a different energiser independently timed the distance between the wires of the two electric fences shall be at least 2 5m If this gap is to be closed this shall be effected by means of e...

Page 11: ... fence wires shall not cross above overhead power or communication lines 11 Crossings with overhead power lines shall be avoided wherever possible If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it 12 If connecting leads and electric fence wires are installed near an overhead power line the clearances shall be not less th...

Page 12: ...nt connected to the electric animal fence circuit provides isolation between the fence circuit and the supply mains equivalent to that provided by the energiser PROHIBITED MOUNTING Electric fence conductors should not be mounted on a support used for any overhead power line PARTICULAR REQUIREMENTS FOR ELECTRIC ANIMAL FENCES IN AUSTRALIA WARRANTY Daken Pty Ltd warrants that this energiser is free f...

Reviews: