INSTRUCTIONS FOR INSTALLATION AND CONNECTION OF 

ELECTRIC FENCES IN AUSTRALIA AS REQUIRED UNDER 

AS3350.2.76

DEFINITIONS

Connecting Lead:

an electric conductor, used to connect the 

energiser

 to the 

electric fence

 or the 

earth electrode.

Electric animal fence:

an 

electric fence

 used to contain animals within or exclude animals from a particular area.

Electric fence:

a barrier which includes one or more electric conductors, insulated from earth, to which electric pulses are 
applied by an 

energiser.

Electric security fence: 

a fence used for security purposes which comprises an 

electric fence

 and a physical barrier electrically 

isolated from the 

electric fence.

GENERAL REQUIREMENTS FOR ELECTRIC FENCES

1.   

Electric fences

 shall be installed and operated so that they cause no electrical hazard to persons, animals 

or their surroundings. 

2.   

Electric fence

 constructions which are likely to lead to the entanglement of animals or persons shall 

be avoided.

3.   An 

electric  fence

  shall  not  be  supplied  from  two  different 

energisers

  or  from  independent  fence 

circuits of the same 

energiser.

 For any two different 

electric fences,

 each supplied from a different 

energiser

 independently timed, the distance between the wires of the two 

electric fences

 shall be at 

least 2.5m. If this gap is to be closed, this shall be effected by means of electrically non-conductive material 

or an isolated metal barrier.

4.   Barbed wire or razor wire shall not be electrified by an 

energiser.

5.   Any part of an 

electric fence

 which is installed along a public road or pathway shall be identified at 

frequent intervals by warning plates securely fastened to the fence posts or firmly clamped to the fence 

wires.

a.   The size of the warning plates shall be at least 100 mm x 200 mm.
b.   The background colour of both sides of the warning plate shall be yellow. The colour on the plate shall 

be black and shall be either:

 i.   The symbol of Figure 4, or
ii.   The substance of TAKE CARE - ELECTRIC FENCE.

c.   The inscription shall be indelible, inscribed on both sides of the warning plate and have a height of at 

least 25 mm.

Summary of Contents for Techfence BT12

Page 1: ... information FREECALL 1800 636 451 email daken nsw clarkequipment com au www daken com au INSTALLATION AND OPERATIONS MANUAL For Techfence Energiser Models Mains Powered MT5 MT15 35 60 and 100 Battery Powered Solar BT12 20 50 and 80 ...

Page 2: ...thout supervision Young children should be supervised to ensure that they do not play with the appliance SCOPE This manual is the users instruction manual for Daken Techfence energisers Models BT12 BT20 BT50 BT80 battery and solar energisers Models MT15 MT35 MT60 MT100 mains operated energisers MT5 For more information please see the DAKEN Electric Fencing Manual and Australian Standard AS3014 DAK...

Page 3: ...olar Powered Energisers 5 Earthing 5 Solar Energiser Kit Installation 6 Checking your Solar Energiser is Operating Correctly 6 Estimated State of charge of a 12V car battery 6 TROUBLE SHOOTING 7 Testing Your Fence 7 TestingThe Earth 7 Fault Finding The Fence 7 INSTRUCTIONS FOR INSTALLATION AND CONNECTION OF ELECTRIC FENCES IN AUSTRALIA AS REQUIRED UNDER AS NZS 60335 2 76 8 DEFINITIONS 8 GENERAL RE...

Page 4: ...ower the BT12 20 50 and 80 will run from a battery that is charged from a solar panel The BT12 requires a 10W panel and at least a 7Ah battery preferably 15Ah The BT20 requires a 20W panel and at least a 15Ah battery perferably 30Ah The BT50 requires a 40W panel and at least a 30Ah battery perferably 60Ah The BT80 requires a 40W panel and at least a 60Ah battery perferably 120Ah Solar regulator re...

Page 5: ...OWERED ENERGISERS Model BT12 Solar BT20 BT50 BT80 Energiser 8 5kV peak no load output voltage Pulse period 1 3 seconds normal 1 7 seconds low battery Stored Energy 1 Joule 2J 5J 8J Power 12V or 24V absolute maximum 30V 12V Drain 85mA 150mA 375mA 570mA Protection Input surge noise and over voltage protected Output surge lightning protection Solar Panel 10 Watt 20 Watt 40 Watt 40 Watt Solar Battery ...

Page 6: ...s featuring digital display a reading of Lo b this means low battery voltage Early models will switch themselves off to conserve the battery on re applying the correct voltage the energiser will start up At this warning indication your battery needs to be re charged to prevent permanent battery damage and loss of fence voltage Should the red overload LED flash 3 or more times in succession or for ...

Page 7: ...d system For detailed information on earthing see the Daken Electric Fencing Manual IMPORTANT NOTE Always ensure adequate ventilation is given to the enclosure if it houses a battery Lead Acid batteries may emit explosive gases while charging Battery Installation Attach the battery leads to the battery The red positive lead to and the black negative lead to on the battery The battery should be ins...

Page 8: ...i r e t e m t l o v e h t h t i W r o t a l u g e r e h t m o r f s e r i w l e n a p e h t t c e n n o c s i D l e n a p r a l o s e h t k c e h c o T 1 range check that the panel is delivering approximately 19V in good sunlight s d a e l r o t a l u g e r e h t t c e n n o c s i D r o t a l u g e r e h t o t n o s d a e l l e n a p r a l o s e h t e c a l p e r r o t a l u g e r e h t k c e h c ...

Page 9: ...s or 3kV Should this point be reached you will need to trouble shoot your fence to determine the presence of short circuits or high load from weed growth See Fault finding the fence on page 7 for assistance or see the Daken Fencing Manual TESTING THE EARTH This requires a Daken Fence Tester or Daken Fault Finder For detailed information on earthing see the Daken Electric Fencing Manual FAULT FINDIN...

Page 10: ...r persons shall be avoided 3 An electric fence shall not be supplied from two different energisers or from independent fence circuits of the same energiser For any two different electric fences each supplied from a different energiser independently timed the distance between the wires of the two electric fences shall be at least 2 5m If this gap is to be closed this shall be effected by means of e...

Page 11: ... fence wires shall not cross above overhead power or communication lines 11 Crossings with overhead power lines shall be avoided wherever possible If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it 12 If connecting leads and electric fence wires are installed near an overhead power line the clearances shall be not less th...

Page 12: ...nt connected to the electric animal fence circuit provides isolation between the fence circuit and the supply mains equivalent to that provided by the energiser PROHIBITED MOUNTING Electric fence conductors should not be mounted on a support used for any overhead power line PARTICULAR REQUIREMENTS FOR ELECTRIC ANIMAL FENCES IN AUSTRALIA WARRANTY Daken Pty Ltd warrants that this energiser is free f...