7
LED indication table
Command
sent to:
LED colour and status
Meaning
Alarm control
panel
flashes ORANGE
while the key
is pressed then...
lights up steady
GREEN for 1.5 s
• Total/Partial or group
DISARMING
or
•
Silent alarm
flashes
GREEN
3 times
Total/partial or group
DISARMING
(with memory of alarm)
lights up
steady RED for 1.5 s
(1)
Total/partial or group
ARMING
flashes
RED
3 times
ARMING
blocked (2)
• An Optwin
®
external
receiver
• A doorphone
controller
flashes ORANGE
once then...
lights up
steady GREEN for 1.5 s
• position contact
OPEN
or
• relay
ENABLED
(e.g.: toggle switch function)
lights up
steady RED for 1.5 s
• position contact
CLOSED
or
• relay
DISABLED
(e.g. toggle switch function)
(1) This is the indication used when the control panel receives an ARM order even if there is a fault or a door or window open.
(2) ARMING blocked means that the intrusion system has been unable to arm owing to a system fault.
The user must check the control panel for more information.
LED indication table
Command sent
to:
LED colour and status
Meaning
• An Optwin
®
external
receiver
• A doorphone
controller
flashes ORANGE
once then...
lights up
steady GREEN for 0.5 s
Radio-transmitted command received correctly
(e.g. pulse function without status indication)
This display only concerns commands with an Optwin
®
wireless product.
Confirmation of receipt is displayed when the product acknowledges the command without indicating its status.
It indicates to the user that the radio message has been received and taken into account (examples: pulse function without
position contact or timer function).
7.2 Confirmation of receipt
When the keyfob has been locked using a code or is in protected mode (SJ608AX with cursor in middle position) the LED
quickly flashes red to indicate locking/protection when a key is pressed (the LED stops flashing when the key is released or
after the key has been pressed for longer than 2 s).
7.3 Protected or locked keys
This fault is indicated by the LED flashing red four times at the start of a sequence when a key is pressed and for however
long the key is pressed.
The battery must be changed within 4 weeks.
The control panel responds to remote control battery faults: Following a system command (for example, ON or OFF), the
control panel issues the voice message
“Beep, fault, voltage, remote control unit X”
.
7.4 Keyfob battery fault
8. Maintenance
IMPORTANT: make sure you
insert the battery the right way
round with the “+” facing up.
IMPORTANT
• When a keyfob is powered (battery changed) in locked
mode it remains in locked mode.
• The parameters set do not change when the keyfob battery
is changed.
• After the battery change , the low battery fault
announcement by the Control panel will be removed
following a second press of a remote control button (for
example press OFF twice).
8.1 Changing the battery
To replace a low battery, see chapter “2. Preparation”.
Dispose of waste batteries
in the appropriate recycling
containers.