IMPORTANT
• Each command n° digit corresponds to the number of times the keyfob is pressed (digit “0” = key pressed 10 times in a row)
• If the red LED flashes three times in a row during or at the end of parameter-setting, you have made a programming error.

When this happens, go through the sequence again from the beginning.

4. Set the parameters 

according to the sequence below.

Example of parameter-setting

Personalise key P1 to trigger a “Silent alarm”. The command n° is 24.

red LED

green LED

R

G

about 

2 s pause

LED off

LED on

press as

shown

about 5 s

about 10 s

about 

1.5 s

about 10 s

about 

2 s pause

R

R

R

R

R

R

R

R

R

R

R

R

R

G

To 

begin,

simultaneously 

press

the 

and 

keys 

until the LED

goes out

Press briefly

on the key 

to be

personalised: 

or 

Press and hold

the key

until 

the LED goes out

and release 

the key when 

the LED lights up

a 2

nd 

time.

Press the key

as many times

as the 

1

st

digit

of the

command n°

To end the

sequence press
and hold

the key

until the LED goes

out.

Steady green
LED =
parameters
correctly set.

Select key 

Start

Press 

to create 

a space

Press twice 

for the 1

st

digit

Press 4 times 

for the 2

nd

digit

2

R

R

R

R

R

R R

4

R R R R

R

R

G

End

Steady green LED =

parameters correctly set

IMPORTANT: a key cannot be set with a TwinBand

®

command n° if an Optwin

®

radio link has already been allocated (unless the

Optwin

®

radio link is deleted).

Verification of parameter setting

of the preceding example

Select key 

Start

Press 

to create 

a space

End

The LED 

flashes

twice

to confirm

the 1

st

digit

The LED 

flashes 

4 times

to confirm

the 2

nd

digit

The green LED lights up 

for 1.5 s at the end 

of consultation

2

R

R

R

R

R

R

R

R R

4

R R R R

G

4.2 Setting a key to Arm or Disarm groups 1 to 8

The arming or disarming of a group from among the 8 alarm groups available (depending on the type of control panel) can be
programmed by first configuring:
• the Disarm group function (command 121) and associating this with the group(s) to be disarmed,
• the Arm group function (command 123) and associating this with the group(s) to be disarmed.

Example of parameter-setting

Personalising the P1 key to trigger the “Off group” function (command 121) associated with groups 1 and 8.

Press briefly

to select 

the 

key

To 

begin,

simulta -

neously 

press

the 

and 

keys

until the LED

goes out

Press and

hold a key

until the

LED goes

out and

release the

key when

the LED

lights up 

a 2

nd

time

Press

once 

for the 

1

st

digit

“Off Group” 

command parameter-setting

Press

twice 

for the 

2

nd

digit

Press

once 

for the 

3

rd

digit

Press and

hold a key

until the LED

goes out and

release the

key when the
LED lights up

a 2

nd

time.

Press 

once

for group 1

Press 

eight 

times

for group 8

1

2

1

1

8

R

R

R

R

R

R

R R

R

R

R

R

R

R

R

R

G

To end the

sequence
press and
hold

a key

until the LED

goes out

Steady green

LED =

parameters

correctly set

Groups 1 and 8

associated

red LED

green LED

R

G

red LED

green LED

R

G

Press the key

as many times

as the 

2

nd

digit

of the

command n°

Press the key

as many times

as the 

3

rd

digit

of the

command n°

Summary of Contents for SH602AX

Page 1: ...peration or maintenance purposes The remote control devices SJ604AX and SJ608AX comb ine two radio protocols TwinBand and Optwin allowing them to control several product ranges The remote control devi...

Page 2: ...osition 5 Guarantee sticker Remove the pre cut part of the sticker and stick it on to the guarantee certificate inside the user manual supplied with the control panel If you are adding to an existing...

Page 3: ...P1 or P2 2 Choose a command n 2 or 3 digits from the table below depending on the command to be set 3 Choose a top or bottom cursor position only for SJ608AX IMPORTANT To use the Alert or Silent alarm...

Page 4: ...ding example Select key Start Press to create a space End The LED flashes twice to confirm the 1st digit The LED flashes 4 times to confirm the 2nd digit The green LED lights up for 1 5 s at the end o...

Page 5: ...ng and deleting the radio link between the remote control keyfob and an Optwin wireless product IMPORTANT An Optwin radio link can be created for a key programmed for a TwinBand command n If the radio...

Page 6: ...d as well as on the type of radio used Events can only be viewed on the remote control unit having issued the order and concern the last key pressed i e the last command issued 1 Or the factory lockin...

Page 7: ...ledges the command without indicating its status It indicates to the user that the radio message has been received and taken into account examples pulse function without position contact or timer func...

Page 8: ...x 14 mm Weight 27 g DECLARATION OF CONFORMITY Manufacturer Hager Security SAS Address F 38926 Crolles Cedex France Product type Remote controls Trade mark Daitem We declare under our sole responsibili...

Reviews: