62
GB
Screw cover
Overview of opening and closing distances between the contact
detector and the magnet used by the built-in contact to analyse any
change in entrance status.
15 mm
9 mm
12 mm
7 mm
15 mm
8 mm
12 mm
6 mm
Built-in contact opening and closing distances
Movement
Contact
status
opening
closing
23 mm
11 mm
22 mm
11 mm
opening
closing
34 mm
20 mm
24 mm
9 mm
24 mm
15 mm
19 mm
8 mm
opening
closing
Spacing
Vertical
sliding
Horizontal
sliding
Wooden support
Soft iron support
t
t
t
t
t
t
t
t
t
t
To unclip the magnet holder cover,
insert a small flat-headed screwdriver
into the slot provided and turn.
2,5
4.
Clip and then screw the
detector to its base. Fit the
screw head plug (supplied
with the bunch of plastic
parts for the magnet
holder) to the cover.