DAITEM SH273AX Installation Manual Download Page 6

61

GB

Cover

Magnet

Spacers

Base

2. 

Adjust the height of the

magnet holder according to

the diagrams below.

3. 

Fix the magnet holder base,

place the magnet inside the

cover and clip it to the base.

1. 

Align the vertical slot on the
magnet holder with the arrow
located on the base of the
detector.

IMPORTANT: the parts must
be laterally aligned and their
height adjusted for the
detector to operate 
correctly.

Max : 

5 mm

Detector

Magnet holder

Spacers

Spacer

If necessary use the spacer supplied for the magnet holder 

or position a spacer below the normally closed detector.

slot-arrow

alignment

Max : 

5 mm

35 mm

4.2 Fixing method and installing the magnet holder

Fix the back plate to the wall using 2 screws suitable for wall fixing. When the entrance is closed the magnet
holder must be positioned opposite the built-in contact less than 5 mm away from it.

Summary of Contents for SH273AX

Page 1: ...Updated for e Nova applications...

Page 2: ...Contents 1 Introduction 57 2 Preparation 58 2 1 Opening 58 2 2 Power supply 58 3 Programming 59 4 Installing 60 4 1 Choosing the best place 60 4 2 Fixing method and installing the magnet holder 61 5 T...

Page 3: ...t need to be accessed for operation or maintenance purposes 2 Preparation 1 Loosen the screws using a cross head screwdriver 2 Unclip the base plate cover When switched on the detector performs a self...

Page 4: ...e the device as follows IMPORTANT the control panel indicates an error by emitting 3 short beeps When this happens programming should be carried out again 10 s max Press then on the control panel keyp...

Page 5: ...product except between 2 detectors 4 1 Choosing the best place The contact detector must be placed inside the protected area preferably on the door frame of the entrance to be protected at least 1 m a...

Page 6: ...terally aligned and their height adjusted for the detector to operate correctly Max 5 mm Detector Magnet holder Spacers Spacer If necessary use the spacer supplied for the magnet holder or position a...

Page 7: ...ct status opening closing 23 mm 11 mm 22 mm 11 mm opening closing 34 mm 20 mm 24 mm 9 mm 24 mm 15 mm 19 mm 8 mm opening closing Spacing Vertical sliding Horizontal sliding Wooden support Soft iron sup...

Page 8: ...Inactive in Test Mode To change this parameter programme To test the detector press the test button and the detector changes to test mode for about 90 sec After this period the detector automatically...

Page 9: ...ator lamp lights up entrance closed the test LED indicator lamp goes out beep test detector X group Y immediate or delayed or combined 6 1 Battery low indication The control panel indicates when the c...

Page 10: ...master code engineer installer code engineer installer code IMPORTANT the detector s configuration is saved when the battery is changed Waste processing of electrical and electronic devices at the en...

Page 11: ...in normal conditions of use Radio links TwinBand 400 800 MHz Test button programming battery and detection test LED Indicator lamp 1 Operating temperature 10 C to 55 C Anti tamper protection against o...

Page 12: ...Product type Contact detector Trade mark Daitem We declare under our sole responsibility that the product to which this declaration relates is compliant with the essential requirements of the followin...

Page 13: ...805350 A 04 2013...

Reviews: