OPERATION

Daisy Power Auto-Roll Function

You can set the Auto-Roll timer function in either 

direction. As the Auto-Roll is a timer, the roller position 

and cord length (how much cord is unrolled off the 

roller) will affect where the Auto Roll will stop.
The Auto-Roll is programmed on the 

‘Tube Motor’ 

buttons

 (forward and reverse on the control 

housing or remote control buttons) after pressing for 

5 seconds

, with hesitation indicator.

To engage Auto-Roll on the 

Tube Motor

, you need to 

press then release the button after the hesitation ‘blip’ 

at 5secs...but before 10secs of holding down either 

the directional control button on the unit or the remote 

control button.
To stop operation, press any button.
To manually operate roller after Auto-Roll press any 

button.
The Auto-Roll has a factory setting of 120 seconds.
To change Auto-Roll run time:

• 

start with pool cover in the normal (start) position 

on the pool.

• 

ensure the control housing ‘asleep’, that is wait over 

3 minutes from any button press.

 

Note:

 AC charger MUST be disconnected.

• 

ensure the disengage pin is engaged.

You can program using either the remote control or 

the buttons on the unit...however using the remote 

within a 1 metre distance will give more consistent 

results (as it is more generous with the timing of 

pressing ‘both buttons at once’)
1.  Start by continually pressing the tube motor button 

for the whole operation that you want to program 

(don’t release the button then press it again), until 

the cover has come off to the desired position on 

the roller then release the directional button to stop 

operation.

2. After releasing the direction button, count to 3.
3. Then press and hold BOTH tube motor direction 

buttons at the same time until it buzzes once 

(approx. count to 5), then release both buttons.

4. After programming, let the control housing go ‘to 

sleep’ (wait over 2 minutes for lights to turn off) 

then test operation. If you press a button before the 

control housing goes to sleep it will NOT remember 

the program just set

5.  Test operation.
If using the remote, make sure you are close to the 

control housing on your unit to make sure there is no 

electrical interference while programming.
If the control housing goes back to sleep or the move 

distance is less than 20 seconds the program will not 

change, so wind out to desired length, double press, 

wind back in again, double press.
To restore Auto-Roll Factory settings:
1.  Start with control housing asleep (control housing 

goes to sleep after 2 minutes of no operation/

button press).

2. Press and hold BOTH tube motor direction buttons 

at the same time until it buzzes twice (approx. count 

to 5), then release both buttons.

3. Allow the control housing to go ‘to sleep’ (wait over 

2 minutes for lights to turn off) then test operation. 

If you press a button before the control housing 

goes to sleep it will NOT remember the program 

just set (factory reset).

Note:

 Control housing won’t go to sleep with AC 

plugged in.

Summary of Contents for Under Bench Roller

Page 1: ...pool covers rollers Quality I Technology I Service AUSTRALIA S FAV URITE 1300 55 18 11 daisypoolcovers com au Installation Instructions Under Bench Roller...

Page 2: ...supports Make sure opening of centre C support is facing towards pool 1x tube assembly with M8x 20mm retaining bolt and washer 1x hand wheel adaptor with M8x 40mm retaining bolt 1x hand wheel 1x cover...

Page 3: ...eel to adaptor using the 6x screws in the adaptor Starting from one end note coloured dots on frame and plank insert one end frame onto the 2 planks while lining up the bolt holes You may need to clip...

Page 4: ...mounting bolts do not tighten Once you confirm the tube turns freely tighten all frame mounting bolts It is easier to get someone to help carefully roll over the UBR and locate it where you want to an...

Page 5: ...ttach to Feather Plug on roller Thread other end through cover eyelet and tie off to cord adjuster or bowline knot e Repeat for all cord attachments then adjust the cords so the cover comes onto the r...

Page 6: ...ve to freew Drive in operation section 2 Without the drive motor inside the tube mark and drill 6x 4 5mm holes through the template with the 4 5mm drill bit there are 3 holes to be drilled around the...

Page 7: ...tant make sure recess is facing DOWN when mounting to frame to avoid water filling up inside 7 Install the control housing secure firmly the 4 x mounting bolts 8 Plug in the drive motor wire to the co...

Page 8: ...ing a button Battery condition light only illuminates when 1 PV solar panel available or 2 AC available or 3 During and immediately after operation for approximately 60 seconds after operation ceases...

Page 9: ...ole operation that you want to program don t release the button then press it again until the cover has come off to the desired position on the roller then release the directional button to stop opera...

Page 10: ...en light Full charged battery voltage 11V AC charger light Red Light Charging the battery voltage 10 5V Yellow light Charging the battery voltage 10 5V 11V Green light Full charged battery voltage 11V...

Page 11: ...icator lights image on this page After fully recharging for a minimum of 3 days to report any fault record what is happening when you test operation press button now AC charger when plugged in will op...

Page 12: ...o this page Register online now at daisypoolcovers com au AUSTRALIA S FAV URITE 1300 55 18 11 hello daisypoolcovers com au daisypoolcovers com au Quality I Technology I Service OPERATION Service Call...

Reviews: