Trouble-shooting Guide
8.2 Division 1 Z-Purge Troubleshooting
PROBLEM
POSSIBLE CAUSE
SUGGESTED SOLUTION
The flow cannot be adjusted up to
150 SCFH during purge
Improper flow meter reading
For correct operation, the purge
unit must be mounted vertically so
that the flow meter is vertically
plumb
Improper regulator adjustment
Adjust the air inlet regulator to
increase air supply
The purge control is not set to
purge
Check the position of the control
valve to ensure that it is set to
“Purge”
Insufficient air supply
Check your purge gas supply to
ensure that it can supply 150 SCFH.
If you cannot achieve 150 SCFH,
then purge times must be
recalculated. Contact DAISY
customer service for assistance.
Restrictions in the air supply line
Check your air supply line for
blockages and kinks
Contamination in the air supply
Ensure that the purge gas supply is
clean, dry, and free of oil – a
water/oil separator should be
installed near the connection to the
purge control
Restrictions in the purge line from
the purge control into the
enclosure
Ensure that the purge line from the
purge control into the enclosure is
not kinked, has no internal
obstructions, and is unrestricted at
its open end (at least 0.5” from any
object in the path of the air flow)
During operation (control valve set
to “Operate”), the internal
pressure does not reach/will not
maintain 1” of water column
The enclosure is not sealed and is
leaking
Ensure that all access doors are
closed and latched. Ensure that all
access panels are closed and sealed.
Make sure no unsealed holes or
openings are present in the
enclosure.
Insufficient air flow
Adjust the regulator on the purge
control to increase the air flow
Pack-Seals are not poured
Pack-Seals must be poured in
conduits entering the enclosure to
prevent air from escaping via the
conduit entry. Ensure that this has
been done.
Exhaust control valve setting
incorrect
Adjust the purge control exhaust
valve for a higher internal pressure.
It may take several minutes for
adjustments to this setting to take
effect.
Summary of Contents for 9017
Page 1: ...February 2022 Model 9017 Y Z Purge User Manual...
Page 23: ...Page 19 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...
Page 24: ...Page 20 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...
Page 25: ...Page 21 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...
Page 26: ...Page 22 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...
Page 27: ...Page 23 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...
Page 28: ...Page 24 Daisy Data Displays Inc Model 9017 Y Z Purge Operator Interface...
Page 29: ...Model 9017 Y Z Purge Operator Interface Daisy Data Displays Inc Page 25...
Page 30: ...Model 9017 Y Z Purge Operator Interface Daisy Data Displays Inc Page 26...
Page 31: ...Model 9017 Y Z Purge Operator Interface Daisy Data Displays Inc Page 27...