This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Conforms to the following standards:
Maximum Remote Mounting Distance from Driver Output
18 AWG/0.82 mm
2
Supply Wire
16 AWG/1.31 mm
2
Supply Wire
14 AWG/2.08 mm
2
Supply Wire
12 AWG/3.31 mm
2
Supply Wire
25W Power Supply
120 ft./36.6 m
-
-
-
80W Power Supply
20 ft./6.1 m
25 ft./7.6 m
35 ft./10.6 m
40 ft./12.1 m
100W Power Supply
20 ft./6.1 m
25 ft./7.6 m
35 ft./10.6 m
40 ft./12.1 m
180W Power Supply
20 ft./6.1 m
25 ft./7.6 m
35 ft./10.6 m
40 ft./12.1 m
200W Power Supply
20 ft./6.1 m
25 ft./7.6 m
35 ft./10.6 m
40 ft./12.1 m
300W Power Supply
20 ft./6.1 m
25 ft./7.6 m
35 ft./10.6 m
40 ft./12.1 m
III
Tetra
®
Atom
Installation Guide
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN268 (Rev 06/29/21) Enovia - A-1023158
NOTE: The maximum loading claimed in the table is at ambient temperature 25°C (77°F).
For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.
Maximum Loading per 24V DC Power Supply
Power Supply
GEAM2471-W1, GEAM2465-W1, GEAM2457-W1,
GEAM2450-W1, GEAM2441-W1, GEAM2432-W1
Rating per module
24V DC, 10.5mA/module, 0.25W/module
GEPS24-25U-NA
Load shall not exceed 1.04A
75 modules/12.5 ft. (3.81 m)
GEPS24D-80U, GEPS24W-80
Load shall not exceed 3.3A
240 modules/40 ft. (12.19 m)
GEPS24-100U-GLX, USVI-100024FBA, USVI-100024FE
Load shall not exceed 4.0A
300 modules/50 ft. (15.24 m)
GEPS24-180U
Load shall not exceed 3.8A per each (of 2) output channels
270 modules/45 ft. (13.72 m) per bank
540 modules/90 ft. (27.43 m) per PS
GEPS24-300U-GL
Load shall not exceed 4.0A per each (of 3) output channels
300 modules/50 ft. (15.24 m) per bank
900 modules/150 ft. (45.72 m) per PS
GEPS24-100U-GLX2/TT
Load shall not exceed 4.0A
327 modules/54.5 ft (16.61 m)
GEPS24-200U-GLX2
Load shall not exceed 4.0A per each (of 2) output channels
327 modules/54.5 ft (16.61 m) per bank
654 modules/109 ft (33.22 m) per PS
GEPS24-300U-GLX2
Load shall not exceed 4.0A per each (of 3) output channels
327 modules/54.5 ft (16.61 m) per bank
981 modules/163.5 ft (49.83 m) per PS