This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005  du Canada.

This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.

Conforms to the following standards: 

Maximum Remote Mounting Distance from Driver Output

18 AWG/0.82 mm

Supply Wire

16 AWG/1.31 mm

Supply Wire

14 AWG/2.08 mm

Supply Wire

12 AWG/3.31 mm

Supply Wire

25W Power Supply

120 ft./36.6 m

-

-

-

80W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

100W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

180W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

200W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

300W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

III

Tetra

®

 Atom 

Installation Guide

www.gecurrent.com

© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the 

General Electric Company and are used under license. Information provided is subject to change without 

notice. All values are design or typical values when measured under laboratory conditions. 
SIGN268 (Rev 06/29/21)  Enovia - A-1023158

NOTE: The maximum loading claimed in the table is at ambient temperature 25°C (77°F).

For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.

Maximum Loading per 24V DC Power Supply

Power Supply

GEAM2471-W1, GEAM2465-W1, GEAM2457-W1, 

GEAM2450-W1, GEAM2441-W1, GEAM2432-W1

Rating per module

24V DC, 10.5mA/module, 0.25W/module

GEPS24-25U-NA 

Load shall not exceed 1.04A

75 modules/12.5 ft. (3.81 m)

GEPS24D-80U,  GEPS24W-80  

Load shall not exceed 3.3A

240 modules/40 ft. (12.19 m)

GEPS24-100U-GLX, USVI-100024FBA, USVI-100024FE 

Load shall not exceed 4.0A

300 modules/50 ft. (15.24 m)

GEPS24-180U 

Load shall not exceed 3.8A per each (of 2) output channels

270 modules/45 ft. (13.72 m) per bank

540 modules/90 ft. (27.43 m) per PS

GEPS24-300U-GL 

Load shall not exceed 4.0A per each (of 3) output channels

300 modules/50 ft. (15.24 m) per bank

900 modules/150 ft. (45.72 m) per PS

GEPS24-100U-GLX2/TT  

Load shall not exceed 4.0A

327 modules/54.5 ft (16.61 m)

GEPS24-200U-GLX2 

Load shall not exceed 4.0A per each (of 2) output channels

327 modules/54.5 ft (16.61 m) per bank

654 modules/109 ft (33.22 m) per PS

GEPS24-300U-GLX2 

Load shall not exceed 4.0A per each (of 3) output channels

327 modules/54.5 ft (16.61 m) per bank

981 modules/163.5 ft (49.83 m) per PS