background image

Arize

®

 Factor 

Installation Guide

8

Connect the green wire to the incoming ground 

conductor. Connect the black wire to Line 1 and white 

wires to Neutral or Line 2 of the incoming AC line.

AC line

To driver input

Mate male connector from lightbar with female 

connector from DC output of driver.

Driver Output and Lightbar Electrical Connections

Male

Lightbar

Secure locknut

Driver

Female

Connection Schematic

Driver Input  Wire Colors
Black = Line 1
White = Neutral or Line 2
Yellow/Green = Ground

Lightbar

AC line

Use proper circuit 

protection level

Optional 3’or 6’ interconnection cable

NOTE: Maximum cumulative length of interconnection cable is 6 feet.

Driver

*White = Neutral or Line 2

*

*

*

Driver

Driver Driver Driver

N

3-Phase Y

REPEAT FOR ENTIRE CIRCUIT BALANCING OUT EACH PHASE

3-Phase ∆

L3
L2
L1

Driver

Driver

Green

Green

Green

Green

Green

Green

Black

Black

Black

Black

Black

Black

White

White

White

White

White

White

1

2

 

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

•  Turn power OFF before inspection, installation or removal.

RISQUE DE CHOC ELECTRIQUE

•  Coupez l’alimentation avant l’inspection, l’installation ou la désinstallation.

Summary of Contents for GE Current Arize Factor

Page 1: ...acity as determined for the maximum temperature of the installed environment specified in the instructions For safe operation and to maximize the longevity of the luminaire ensure that the lightbar an...

Page 2: ...t GEPSC210 600D ADGNA D1XA1 Cord w Leads 3 33 kg 7 3lbs 120 208 240 277 VAC 6 3 5 3 2 6A GEPSC210 600D ADGNA D15A1 NEMA 5 15P 3 48 kg 7 33lbs 120 VAC 6A GEPSC210 600D ADGNA D16A1 NEMA L6 15P 3 48 kg 7...

Page 3: ...ils GEPSC210 600 A NA Series LED Driver Optional Interconnection cable 93118692 93067607 Rolling Rack Mount 48 GEMB BAW2 Rolling Rack Mount 24 GEMB BAW1 Suspended Wire Form Support GEMB BANE 1 4 1 4 2...

Page 4: ...ng the two screws located at each end of the bracket After the horizontal bracket is attached to the strut secure the bracket to the struts by tightening the two screws located each end of the bracket...

Page 5: ...L Series lightbar can suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar A Adjust screws to l...

Page 6: ...the screws shown Components required GEHAK NN NE N0 Driver universal 1 remote mount kit 95047411 2 required Insert each toggle into the hole in the top of each driver bracket Wrap the two toggle cable...

Page 7: ...l not light The shorting cap must be secured such that it does not touch the light bar Shorting Cap Installation ML900 Electrical Connection 2 Lightbars only Shorting Cap ML 300 Electrical connection...

Page 8: ...r Line 2 Yellow Green Ground Lightbar AC line Use proper circuit protection level Optional 3 or 6 interconnection cable NOTE Maximum cumulative length of interconnection cable is 6 feet Driver White N...

Page 9: ...structions for rest of connection Junction Box Cover Replacement Ensure gasket is sitting in place on the inner edge of the junction box cover Fasten all 6 screws to ensure water tight seal NOTE Be ca...

Page 10: ...ddress these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces ave...

Reviews: