background image

Arize

®

 Factor 

Installation Guide

2

LED Driver Specifications

Lightbar Specifications

Interconnection Cables Specifications

SKU

Description

Detailed Description

Weight

93118692

GECA30A14-AA03B

Interconnection cable greenhouse 3 feet, UL

0.16kg (0.4 lbs)

93067607

GECA30A14-AA06B

Interconnection cable greenhouse 6 feet, UL

0.32kg (0.7 lbs)

Mounting Accessories

SKU

Description

Detailed Description

Weight

GEMB-BANE

Factor suspended mount wireform support

0.012 kg (0.026lbs)

GEMB-BAW1

Factor rolling rack mount, 24 inch pitch

1.756 kg (3.86 lbs)

GEMB-BAW2

Factor rolling rack mount, 48 inch pitch

3.69 kg (8.1 lbs)

GEMB-FANE

Factor light engine mount

3.82 kg (8.4 lbs)

95047411

GEHAK-NN-NE-N0

Driver universal 1’ remote mount kit

0.2kg (0.4 lbs)

95050824

GEHR-HAR M15

Shorting cap

0.05kg (0.11lb)

Description

Detailed Description Weight

Driver Max Input Ratings

Voltage

Current

GEPSC210-600D-ADGNA-D1XA1

Cord /w Leads

3.33 kg (7.3lbs)

120/208/240/277 VAC

6 / 3.5 / 3 / 2.6A

GEPSC210-600D-ADGNA-D15A1

NEMA 5-15P

3.48 kg (7.33lbs)

120 VAC

6A

GEPSC210-600D-ADGNA-D16A1

NEMA L6-15P

3.48 kg (7.33lbs)

240 VAC

3A

GEPSC210-600D-ADGNA-D17A1

NEMA L7-15P

3.48 kg (7.33lbs)

277 VAC

2.6A

GEPSC210-600G-AGJNA-D1XA1

Cord /w Leads

3.33 kg (7.3lbs)

277/347VAC

2.5 / 2A

GEPSC210-600G-AGJNA-D17A1

NEMA L7-15P

3.48 kg (7.33lbs)

277 VAC

2.5A

Product Code

Detailed Description

Weight

Series Load  

per Driver

System Watts 

 per Lightbar

GEHF-HPKRW1*

ML900, PKR

2.6 kg (5.7lbs)

2

319W

GEHF-HPKBW1*

ML900, PKB

2.6 kg (5.7lbs)

2

313W

GEHF-HPKFW1

ML900, PKF

2.6 kg (5.7lbs)

2

313W

GEHF-HBRIW1*

ML900, BRI

2.6 kg (5.7lbs)

2

319W

GEHF-HBRVW1*

ML900, BRV

2.6 kg (5.7lbs)

2

316W

GEHF-MPKRW1

ML300, PKR

2.6 kg (5.7lbs)

4, 5, or 6

104W

GEHF-MPKBW1

ML300, PKB

2.6 kg (5.7lbs)

4, 5, or 6

104W

GEHF-MPKFW1

ML300, PKF

2.6 kg (5.7lbs)

4, 5, or 6

106W

GEHF-MBRIW1

ML300, BRI

2.6 kg (5.7lbs)

4, 5, or 6

106W

GEHF-MBRVW1

ML300, BRV

2.6 kg (5.7lbs)

4, 5, or 6

106W

* Risk Group 1 for photobiological per IEC 62471. All others in Exempt group.

Summary of Contents for GE Current Arize Factor

Page 1: ...acity as determined for the maximum temperature of the installed environment specified in the instructions For safe operation and to maximize the longevity of the luminaire ensure that the lightbar an...

Page 2: ...t GEPSC210 600D ADGNA D1XA1 Cord w Leads 3 33 kg 7 3lbs 120 208 240 277 VAC 6 3 5 3 2 6A GEPSC210 600D ADGNA D15A1 NEMA 5 15P 3 48 kg 7 33lbs 120 VAC 6A GEPSC210 600D ADGNA D16A1 NEMA L6 15P 3 48 kg 7...

Page 3: ...ils GEPSC210 600 A NA Series LED Driver Optional Interconnection cable 93118692 93067607 Rolling Rack Mount 48 GEMB BAW2 Rolling Rack Mount 24 GEMB BAW1 Suspended Wire Form Support GEMB BANE 1 4 1 4 2...

Page 4: ...ng the two screws located at each end of the bracket After the horizontal bracket is attached to the strut secure the bracket to the struts by tightening the two screws located each end of the bracket...

Page 5: ...L Series lightbar can suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar A Adjust screws to l...

Page 6: ...the screws shown Components required GEHAK NN NE N0 Driver universal 1 remote mount kit 95047411 2 required Insert each toggle into the hole in the top of each driver bracket Wrap the two toggle cable...

Page 7: ...l not light The shorting cap must be secured such that it does not touch the light bar Shorting Cap Installation ML900 Electrical Connection 2 Lightbars only Shorting Cap ML 300 Electrical connection...

Page 8: ...r Line 2 Yellow Green Ground Lightbar AC line Use proper circuit protection level Optional 3 or 6 interconnection cable NOTE Maximum cumulative length of interconnection cable is 6 feet Driver White N...

Page 9: ...structions for rest of connection Junction Box Cover Replacement Ensure gasket is sitting in place on the inner edge of the junction box cover Fasten all 6 screws to ensure water tight seal NOTE Be ca...

Page 10: ...ddress these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces ave...

Reviews: