Daikin VRVWII RWEYQ10MY1 Operation Manual Download Page 10

5

English

FOR SYSTEMS WITHOUT COOL/HEAT SELEC-
TOR (Refer to figure 4)

Press the operation mode selector button sev-
eral times and select the operation mode of 
your choice;

” Cooling operation

” Heating operation

” Automatic operation

” Fan only operation

NOTE

• Automatic operation (Heat recovery system only)

In this operation mode, cool/heat changeover is 
automatically performed.

Press the on/off button.
The operation lamp lights up and the system 
starts operation.

FOR SYSTEMS WITH COOL/HEAT SELECTOR 
(Refer to figure 4 and 7)

Select operation mode with the Cool/Heat 
selector as follows:

” “

” Cooling operation 

(Refer to figure 7.1)

” “

” Heating operation 

(Refer to figure 7.2)

” 

 Fan only operation 

(Refer to figure 7.3)

Press the on/off button. 

(Refer to figure 4)

The operation lamp lights up and the system 
starts operation.

ADJUSTMENT (Refer to figure 4)

For adjustment the desired temperature, fan 
speed and air flow direction (only for the 
remote controller BRC1A51: FXC, FXF, FXH, 
FXK, FXA), follow the procedure shown below.

Press the temperature setting button and set 

the desired temperature.

Each time this button is pressed, the tem-
perature setting rises or lowers 1°C.

NOTE

• Set the temperature within the operation range.
• The temperature setting is impossible for fan 

only operation.

Press the fan speed control button and select 
the fan speed of your preference.

Press air flow direction adjust button.
Refer to the chapter “Adjusting the air flow 
direction” for details.

STOPPING THE SYSTEM (Refer to figure 4)

Press the on/off button once again.
The operation lamp goes off and the system 
stops operation.

NOTE

• Do not turn off the power immediately after 

the unit stops.

• The system needs at least 5 minutes for 

residual operation of drain pump device.
Turning off the power immediately will cause 
water leak or trouble.

EXPLANATION OF HEATING OPERATION

• In heating operation, it may generally take longer 

to reach the set temperature than in cooling oper-
ation. 
We recommend starting the operation with timer.

Hot start operation

In order to prevent cold air from blowing out of an 
indoor unit at the start of heating operation, the 
indoor fan is automatically stopped. The display of 
the remote controller shows “

”.

NOTE

• Do not place appliances which produce open fire 

in places exposed to the air flow from or under the 
indoor unit.

• It takes some time for the room to warm up from 

the time the unit is started since the unit uses a 
hot-air circulatory system to warm the entire 
room.

• If the hot air rises to the ceiling, leaving the area 

above the floor cold, we recommend using the cir-
culator (the indoor fan for circulating air). Contact 
your dealer for details.

5-2 PROGRAM DRY OPERATION

• The function of this operation is to decrease the 

humidity in your room with a minimum tempera-
ture decrease.

• The microcomputer automatically determines 

temperature and fan speed.

• The system does not go into the operation if the 

room temperature is low.

• The microcomputer automatically controls the 

temperature and fan speed, so these cannot be 
set by using the remote controller.

• This function is not available if the room tempera-

ture is 20°C or lower.

FOR SYSTEMS WITHOUT COOL/HEAT SELEC-
TOR (Refer to figure 5)

Press the operation mode selector button sev-
eral times and select “

” ( program dry oper-

ation).

Press the on/off button
The operation lamp lights up and the system 
starts operation.

1

2

1

2

3

4

5

6

1

2

01_EN_3P153897-1.fm  Page 5  Wednesday, March 2, 2005  3:32 PM

Summary of Contents for VRVWII RWEYQ10MY1

Page 1: ...riebsanweisung VRVWII System Klimaanlage Manuel d utilisation Conditionneur d air VRVWII System Manual de operaci n Sistema de acondicionador de aire VRVWII Manuale d uso Condizionatore d aria a siste...

Page 2: ...lo desea puede consultar detalles sobre la unidad interior en el manual de funcionamiento pro vistoconlamisma Guardeel manualdefuncionamientoconlaunidad interior y con este manual en un lugar seguro C...

Page 3: ...2 1 4 2 NOT AVAILABLE 3 5 00_CV_3P153897 1 fm Page 3 Friday March 4 2005 1 41 PM...

Page 4: ...5 6 8 7 1 7 2 7 3 9 00_CV_3P153897 1 fm Page 4 Friday March 4 2005 1 41 PM...

Page 5: ...10 11 13 12 Double flow Ceiling Suspended Wall Mounted Multi flow Corner 14 Heat pump system Heat recovery system 00_CV_3P153897 1 fm Page 5 Friday March 4 2005 1 41 PM...

Page 6: ...er leakage electric shock and fire Do not put a finger a rod or other objects into the air inlet or outlet As the fan is rotating at high speed it will cause injury Never touch the air outlet or the h...

Page 7: ...ing conductor or telephone earth wire Arrange the drain hose to ensure smooth drainage Incomplete drainage may cause wet ting of the building furniture etc Do not let children play on and around the o...

Page 8: ...during operation 3 Display changeover under control It is impossible to changeover heat cool with the remote controller which display this icon 4 Display air flow flap Refer to the chapter Operation p...

Page 9: ...g conditions the safety device may be activated and the unit becomes not operational or condensed water drops from an indoor unit This value shows a quantity of water per one outside unit NOTE To avoi...

Page 10: ...ediately after the unit stops The system needs at least 5 minutes for residual operation of drain pump device Turning off the power immediately will cause water leak or trouble EXPLANATION OF HEATING...

Page 11: ...only for FXC FXF FXH FXK FXA Press the air flow direction button to select the air direction The air flow flap display swings as shown right and the air flow direction continuously varies Automatic s...

Page 12: ...ontroller can select heating automatic or cooling operation The displays of slave remote controllers show changeover under control and they automatically follow the operation mode directed by the mast...

Page 13: ...parallel during cooling or dry operation and set it downwards during heat ing operation Do not let the air blow directly to a person Make sure that the inlet and outlet of the indoor unit are not clog...

Page 14: ...nd stops but then restarts after a few minutes This is because the remote control is intercepting noise from electrical appliances other than the air conditioner and this prevents communication betwee...

Page 15: ...at the start or immediately after stopping operation This is the noise of refrigerant gas caused by flow stop or flow change 8 9 DUST COMES OUT OF THE UNIT When the unit is used after stopping for a...

Page 16: ...estored If power failure occurs during operation the system automati cally restarts immediately after the power supply is recovered Check if no fuse has blown Turn off the power supply Check if the br...

Page 17: ...tc it will cause toxic gas to be generated When a refrigerant leakage failure has been repaired confirm a service person that the leakage point has been corrected surely before restarting operation Do...

Page 18: ...f maintenance cycle and replacement cycle needs to be considered in the following cases 1 When used in hot humid locations or locations where temperature and humidity fluctuate greatly 2 When used in...

Page 19: ...sales service etc consult with your dealer Warranty period This product includes a warranty card The warranty card is given to a customer after dealer staff fills out necessary items in the card The c...

Page 20: ...3P153897 1A EM04A065 0503 HT 00_CV_3P153897 1 fm Page 6 Friday March 4 2005 1 41 PM...

Reviews: