12

Hot air is emitted even though the unit is stopped

Hot air can be felt when the unit is stopped.

Several different indoor units are being run on the same system, so if another unit is running, some refrigerant will still flow through the unit.

Does not cool very well

Dry operation.

Dry operation is designed to lower the room temperature as little as possible.  
Refer to page5

.

Trouble Shooting

If one of the following malfunctions occur, take the measures shown below and contact your local dealer.

 Warning

Stop operation and shut off the power if anything unusual occurs (burning smells, etc.)

Leaving the unit running under such circumstances may cause breakage, electrical shock, or fire.
Contact your local dealer.

• If a safety device such as a fuse or a breaker frequently actuates;  

Measure : Do not turn on the main power switch.

• If the ON/OFF switch does not properly work; 

Measure : Turn off the main power switch.

• If water leaks from unit; 

Measure : Stop the operation.

• The operation mode selector button does not work well. 

Turn off the power.

If the system does not properly operate except for the above mentioned cases and none of the above mentioned 

malfunctions is evident, investigate the system according to the following procedures.

Let them know the symptoms, system name, and model name.

1. If the system does not operate at all;

• Check if there is no power failure. 

Wait until power is restored. If power failure occurs during operation, the system automatically restarts immediately after the 
power supply is recovered.

• Check if no fuse has blown; 

Turn off the power supply.

• Check if the breaker is blown. 

Turn the power on with the breaker switch in the OFF position. 
Do not turn the power on with the breaker switch in the Trip position. 
(Contact your local dealer.)

2. If the system stops soon after starting the operation;

• Check if air inlet or outlet of outside or indoor unit is not blocked by obstacles. 

Remove any obstacle and make it well-ventilated.

• Check if the remote controller display shows “Time to clean filter & element”;

Refer to the Operation Manual of the indoor unit. And clean the air filter or element.

3. The system operates but cooling or heating is insufficient;

• Check if air inlet or outlet of outside or indoor unit is not blocked by obstacles. 

Remove any obstacle and make it well-ventilated.

• Check if the remote controller display shows “Time to clean filter & element”;

Refer to the Operation Manual of the indoor unit. And clean the air filter or element.

• Check the temperature setting. 

Refer to “Operation Procedure”.

Breaker 

ON

OFF

Switch

Trip position

Trouble Shooting

• Check the fan speed setting on your remote controller. 

Refer to “Operation Procedure”.

• Check for open doors or windows.  

Shut doors and windows to prevent wind from coming in.

• Check if there are too many occupants in the room during cooling operation.
• Check if the heat source of the room is excessive during cooling operation.
• Check if direct sunlight enters the room during cooling operation.  

Use curtains or blinds.

• Check if the air flow angle is not proper.

Refer to “Operation Procedure”.

After-Sales Service and Warranty

After-sale Service

 Danger

Exposure to this gas could cause severe injury or death.

 Warning

Do not disassemble, modify or repair the unit.

This may cause water leakage, electric shock or fire.
Contact your local dealer.

Do not remove or reinstall the unit by yourself.

Incorrect installation may cause water leakage, electrical shock or fire.
Contact your local dealer.

When asking your local dealer to repair, inform related staff of the details as follows:

• Model name and product No. of air conditioner
• Shipping date and installation date
• Malfunction:  

 

Inform the staff of the defective details. (Malfunction code being displayed on the remote controller.)

• Name, address, telephone number

Repair after the warranty term is expired
Contact your local dealer. If necessary to repair, pay service is available.

Minimum storage period of important parts
Even after a certain type of air conditioner is discontinued, we have the related important parts in stock for 9 years at least. 
The important parts indicate parts essential to operate the air conditioner.

Recommendations for maintenance and inspection
Since dust collects after using the unit for several years, the performance will be deteriorated to some extent. 
Disassembling and cleaning inside require technical expertise, so we recommend entering a maintenance and inspection 
contract (at a cost) separate from normal maintenance.

Recommended inspection and maintenance cycles

[Note: The maintenance cycle is not the same as the warranty period.]
Table 1 assumes the following usage conditions.

1.  Normal use without frequent starting and stopping of the machine. 

(Although it varies with the model, we recommend not starting and stopping the machine more than 6 times/hour for 
normal use.)

2.  Operation of the product is assumed to be 10 hours/day and 2,500 hours/year.

01_EN_3P591322-1.indd   12

2019/10/23   9:25:41

Summary of Contents for VRV IV-S RXTQ36TAVJ9A

Page 1: ...MODEL RXTQ36TAVJ9A RXTQ48TAVJUA RXTQ60TAVJUA 00_CV_3P591322 1 indd 1 2019 10 23 9 23 14...

Page 2: ...aws or ordinances Packing materials such as nails and other metal or wood parts including plastic packing materials used for transportation may cause injuries or death by suffocation WARNING Contact y...

Page 3: ...sunlight The LCD display can become discolored and may result in fail to display the data Do not wipe the controller operation panel with benzene thinner chemical dust cloth etc The result may be tha...

Page 4: ...ess you are licensed to do so Consult with your local dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure to use the...

Page 5: ...nance 6 Reference Information 7 Optimum Operation 8 Seasonal Maintenance 8 Following Symptoms are not Air Conditioner Troubles 9 Trouble Shooting 11 After Sales Service and Warranty 12 The original in...

Page 6: ...re High side psig MPa Low side psig MPa 39 37 12 5 8 990 940 320 RXTQ36TAVJ9A SINGLE 60 208 230 34 200 37 000 172 78 R410A 6 4 2 9 478 3 3 362 2 5 RXTQ48TAVJUA SINGLE 60 208 230 45 500 49 500 176 80 R...

Page 7: ...tioner is operated continuously while the indoor temperature is 70 FDB 21 CDB or below and the humidity is 80 or over the interiors of the indoor units may cause icing and water leakage may result Hea...

Page 8: ...that came with the remote controller Operation Procedure Operation procedure varies according to the combination of outdoor unit and remote controller Read the chapter What to do before Operation Do...

Page 9: ...Heat and Auto are all only available for selection on the COOL HEAT changeover master indoor unit The following table indicates the available operating modes of the other indoor units on the system b...

Page 10: ...ting Main Menu Reset Filter Indicator Air Flow Direction Ventilation Schedule Off Timer Celsius Fahrenheit 1 2 Cool Set to Cool 74F Press buttons to select Reset Filter Indicator on the main menu scre...

Page 11: ...dealer of the Error code and model name or code Precautions for Group Control System or Two Remote Controller Control System This system provides two other control systems beside individual control on...

Page 12: ...r blow directly to a person It takes time for the room temperature to reach the set temperature We recommend starting the operation in advance using schedule operation Seasonal Maintenance Caution Tou...

Page 13: ...cally restarts when the noise goes away Cool heat cannot be changed over When the display shows MASTER CONTROLLED It shows that this is a slave remote controller Refer to Setting the Cool Heat Change...

Page 14: ...ipping water is heard while the indoor unit is stopped When the other indoor unit is in operation this noise is heard In order to prevent oil and refrigerant from remaining in the system a small amoun...

Page 15: ...cording to the following procedures Let them know the symptoms system name and model name 1 If the system does not operate at all Check if there is no power failure Wait until power is restored If pow...

Page 16: ...rm the staff of the defective details Malfunction code being displayed on the remote controller Name address telephone number Repair after the warranty term is expired Contact your local dealer If nec...

Page 17: ...eatly 2 When used in locations where power fluctuation voltage frequency wave distortion etc is high Cannot be used if it is outside the allowable range 3 When installed and used in locations where bu...

Page 18: ...ntact your local dealer for discarding this unit since it is required by law to collect transport and discard the refrigerant in accordance with chlorofluorocarbon collection and destruction law Where...

Page 19: ...2001 3P591322 1 EM19A002 HT Daikin Texas Technology Park 19001 Kermier Road Waller TX 77484 U S A 00_CV_3P591322 1 indd 2 2019 10 23 9 23 15...

Reviews: