Operation Range
COOLING
HEATING
Outdoor temperature
Indoor temperature
57 to 77°FWB (14 to 25°CWB)
59 to 80°FDB (15 to 27°CDB)
Indoor humidity
80%
—
Note
• Cooling operation:
If the air conditioner is operated continuously while the indoor temperature is 70°FDB (21°CDB) or below and the humidity is 80% or
over, the interiors of the indoor units may cause icing and water leakage may result.
• Heating operation:
The air conditioner may stop operating for the protection of the machine if the outdoor temperature is 70°FDB (21°CDB) or over.
Cool/heat changeover
remote controller
If your installation has a customized control system, ask your local dealer for the operation that corresponds to your system.
23 to 122°FDB (– 5 to 50°CDB) – 4 to 60°FWB (– 20 to 15.5°CWB)
Name and Function of Each Switch and Display
Cool/Heat Selector
When the Cool/Heat selector remote controller is installed, the remote controller connected to the indoor unit cannot be used
to switch between cooling and heating operation.
<Cool/Heat selector>
1. Fan only/air conditioning selector switch
• Set the switch to “
” for fan only operation or to “
” for heating or cooling
operation.
2. COOL/HEAT changeover switch
• Set the switch to “
” for cooling operation or to “
” for heating operation.
Remote controller
• For more information, see the operation manual that came with the remote controller.
Operation Procedure
• Operation procedure varies according to the combination of outdoor unit and remote controller. Read the chapter “What to do
before Operation”.
• Do not turn it off during the air conditioning season for starting operation smoothly.
• If the main power supply is turned off during operation, operation will restart automatically after the power turns back on again.
Cooling, Heating and Fan only operation
• Select operation mode with the Cool/Heat selector as follows:
Cooling operation
Heating operation
Fan only operation
• Press On/Off button.
The operation lamp lights up and the system starts operation.
• The system can now be controlled from the remote controller.