![background image](http://html1.mh-extra.com/html/daikin/vrv-iii-s/vrv-iii-s_installation-manual_2459200004.webp)
Installation manual
1
RXYSQ4~ RXYSQ4~6P7Y1B
VRVIII-S system air conditioner
4PW35338-1
C
ONTENTS
Page
Safety considerations ................................................................ 1
Introduction................................................................................ 2
Combination ................................................................................... 2
Standard supplied accessories ...................................................... 2
Optional accessories...................................................................... 2
Technical and electrical specifications ........................................... 2
Before installation ...................................................................... 3
Precautions for R410A ................................................................... 3
Handling ......................................................................................... 3
Selecting installation site ........................................................... 3
Precautions on installation......................................................... 4
Installation method for prevention of falling over ............................ 4
Method for removing transportation stay........................................ 4
Method for installing drain piping ................................................... 4
Installation servicing space ....................................................... 5
Refrigerant pipe size and allowable pipe length ........................ 5
Selection of piping material............................................................ 6
Precautions on refrigerant piping............................................... 6
Cautions for brazing ....................................................................... 6
Cautions for flare connection ......................................................... 6
Refrigerant piping ...................................................................... 7
Preventing foreign objects from entering........................................ 7
Cautions for handling stop valve .................................................... 7
How to use the stop valve .............................................................. 8
Cautions for handling the valve cover ............................................ 8
Cautions for handling service port ................................................. 8
Leak test and vacuum drying ....................................................... 10
10. Additional refrigerant charge ................................................... 10
10.1. Important information regarding the refrigerant used................... 10
10.2. 3 procedures for adding refrigerant.............................................. 11
11. Electrical wiring work ............................................................... 13
11.1. Internal wiring – Parts table ......................................................... 13
11.2. Precautions on electrical wiring work........................................... 14
11.3. Connection example of total system wiring.................................. 14
11.4. Connecting power wire and transmission wires ........................... 15
11.5. Power circuit and cable requirements .......................................... 15
12. Before operation ...................................................................... 17
12.1. Service precautions ..................................................................... 17
12.2. Checks before initial start-up........................................................ 17
12.3. Field setting.................................................................................. 17
12.4. Test operation............................................................................... 19
12.5. Checks in normal operation ......................................................... 20
12.6. Temperature adjustment operation confirmation.......................... 20
13. Service mode operation........................................................... 21
14. Caution for refrigerant leaks .................................................... 21
15. Disposal requirements............................................................. 22
1. S
AFETY
CONSIDERATIONS
The precautions listed here are divided into the following two types.
Both cover very important topics, so be sure to follow them carefully.
Warning
■
Ask your dealer or qualified personnel to carry out installation
work. Do not install the machine by yourself.
Improper installation may result in water leakage, electric shocks
or fire.
■
Perform installation work in accordance with this installation
manual.
Improper installation may lead to water leakage, electric shocks
or fire.
■
When a unit is installed in a small room, it is necessary to take
measures so that the leaked refrigerant amount does not exceed
the limit even if it leaks. As for the measures to prevent the leak
from not exceeding the limit, please consult with your distributor.
If the leaked amount exceeds the limit, it may cause an oxygen
deficiency accident.
■
Be sure to use only the specified accessories and parts for
installation work.
Failure to use the specified parts may result in water leakage,
electric shocks, fire, or the unit falling.
■
Install the air conditioner on a foundation that can withstand its
weight.
Insufficient strength may result in the fall of equipment and
causing injury.
■
Carry out the specified installation work in consideration of strong
winds, typhoons, or earthquakes.
Improper installation work may result in accidents due to fall of
equipment.
RXYSQ4P7V3B
RXYSQ4P7Y1B
RXYSQ5P7V3B
RXYSQ5P7Y1B
RXYSQ6P7V3B
RXYSQ6P7Y1B
VRVIII-S system air conditioner
Installation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
DAIKIN EQUIPMENT IS DESIGNED FOR COMFORT
APPLICATIONS. FOR USE IN OTHER APPLICATIONS,
PLEASE CONTACT YOUR LOCAL DAIKIN DEALER.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DEALER FOR ADVICE AND
INFORMATION.
THIS AIR CONDITIONER COMES UNDER THE TERM
"APPLIANCES NOT ACCESSIBLE TO THE GENERAL
PUBLIC".
WARNING
If the warning is not observed, it may cause serious casualties.
CAUTION
If the caution is not observed, it may cause injury or damage to the
equipment.