8-2 AT THE END OF THE SEASON

On a clear day, use fan operation for around half a 
day to thoroughly dry out the interior of the unit.

• Refer to chapter 6 for details on fan operation.

Turn off the power.

• When the power is shut off, the characters in the 

remote controller display disappear.

• When the power is on, the unit consumes up to 

several dozen Watts of power.
Turn off the power to conserve energy.

Clean the exterior.

• See the operation manual included with the 

indoor unit for details on how to clean it.

9. FOLLOWING SYMPTOMS ARE NOT 

AIR CONDITIONER TROUBLES

9-1 THE SYSTEM DOES NOT OPERATE

The air conditioner does not start immediately 
when restart the operation after stop the oper-
ation or change operation mode after set the 
operation mode.

If the operation lamp lights, the system is in nor-
mal condition.
To prevent overloading of the compressor motor, 
the air conditioner starts 5 minutes after it is turned 
ON again in case it was turned OFF just before.

If “Centralized Control” is displayed on the 
remote controller and pressing the operation 
button causes the display to blink for a few 
seconds.

This indicates that the central device is controlling 
the unit.
The blinking display indicates that the remote 
control cannot be used.

The system does not start immediately after 
the power supply is turned on.

Wait one minute until the micro computer is pre-
pared for operation.

9-2 IT STOPS SOMETIMES

The remote controller display reads “U4” or “U5” 
and stops but then restarts after a few minutes.

This is because the remote control is intercepting 
noise from electrical appliances other than the air 
conditioner, and this prevents communication 
between the units, causing them to stop.
Operation automatically restarts when the noise 
goes away.

9-3 COOL/HEAT CANNOT BE CHANGED 

OVER

When the display shows 

 

(changeover under control).

It shows that this is a slave remote controller.
Refer to “Setting the master remote controller”.

When the cool/heat selector switch is 
installed and the display shows 

 

(changeover under control).

This is because cool/heat changeover is con-
trolled by the cool/heat selector. Ask your Daikin 
dealer where the remote control switch is installed.

9-4 FAN OPERATION IS POSSIBLE, BUT 

COOLING AND HEATING DO NOT 
WORK

Immediately after the power is turned on.

The micro computer is getting ready to operate.
Wait 10 minutes.

9-5 THE FAN STRENGTH DOES NOT COR-

RESPOND TO THE SETTING

The fan strength does no change even if the 
fan strength adjustment button in pressed.

During heating operation, when the room temper-
ature reaches the set temperature, the outdoor 
unit goes off and the indoor unit changes to whis-
per fan strength.
This is to prevent cold air blowing directly on occu-
pants of the room.
The fan strength will not change even if the button 
is changed, when another indoor unit is in heating 
operation.

9-6 THE FAN DIRECTION DOES NOT COR-

RESPOND TO THE SETTING

The fan direction does not correspond to the 
remote control display.
The fan direction does not swing.

This is because the unit is being controlled by the 
micro computer. Refer to “Adjusting the air flow 
direction”.

9-7 WHITE MIST COMES OUT OF A UNIT

Indoor unit

When humidity is high during cooling operation.

If the interior of an indoor unit is extremely con-
taminated, the temperature distribution inside a 
room becomes uneven. It is necessary to clean 
the interior of the indoor unit. Ask your Daikin 
dealer for details on cleaning the unit. This opera-
tion requires a qualified service person.

01_EN_3P201178-2B.fm  Page 10  Wednesday, April 25, 2007  3:51 PM

Summary of Contents for VRV III REYQ8PY1B

Page 1: ...tem air conditioner Betriebsanweisung VRVIII System Klimaanlage Manuel d utilisation Conditionneur d air VRVIII System Manual de operaci n Sistema de acondicionador de aire VRVIII Manuale d uso Condiz...

Page 2: ...a de garant a de la tienda guarde en un lugar seguro Grazie per avere acquistato questo condizionatore d aria Daikin Prima di utilizzare quest ultimo leggere attentam ente il presente manuale d uso ch...

Page 3: ...2 1 4 3 5 6 7 1 7 3 7 2...

Page 4: ...8 9 10 11 12 Ceiling Suspended Wall Mounted Double flow Multi flow Corner 13 1 15 14 13 2 Ceiling Suspended Wall Mounted Double flow Multi flow Corner...

Page 5: ...n contact with any kind of heater stove or other sim ilar objects Turn off any combustible heating devices ventilate the room and contact the dealer where you pur chased the unit When repairing a refr...

Page 6: ...sure to stop the operation and turn the breaker off before cleaning This may cause electric shock and injury Consult with the dealer for cleaning the interior of the indoor units Incorrect cleaning m...

Page 7: ...ensed to do so Consult with your dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure to use the following places a Pl...

Page 8: ...spection test operation When the inspection test operation button is pressed the display shows the mode in which the system actually is 10 Display under centralized control When this display shows the...

Page 9: ...outdoor temperature is 21 C or over 6 OPERATION PROCEDURE Operation procedure varies according to the com bination of outdoor unit and remote controller Read the chapter What to do before operation To...

Page 10: ...utdoor unit heat exchanger increases Heating capability decreases and the system goes into defrost operation The airflow will be set to breeze or stop If stopped the display of the remote control ler...

Page 11: ...swings as shown right and the air flow direction continuously varies Automatic swing setting Press the air flow direction adjust button to select the air direction of your choice The air flow flap di...

Page 12: ...L HEAT Selector is connected to BS unit The COOL HEAT Selector can select opera tion mode Only the master remote controller can select heating cooling automatic operation The displays of slave remote...

Page 13: ...lar equipment Failing to do so may cause static or distorted pic tures Turn off the main power supply switch to the unit when the unit is not used for longer periods of time If the switch is on it use...

Page 14: ...ommunication between the units causing them to stop Operation automatically restarts when the noise goes away 9 3 COOL HEAT CANNOT BE CHANGED OVER When the display shows changeover under control It sh...

Page 15: ...his is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operation or defrost operation This is the n...

Page 16: ...power on with the breaker switch in the trip position Contact your dealer 2 If the system stops soon after starting the opera tion Check if air inlet or outlet of outdoor or indoor unit is not blocke...

Page 17: ...duct is assumed to be 10 hours day 2500 hours year Table 1 Inspection Cycle and Maintenance Cycle Lists Note 1 This table indicates main parts See the maintenance and inspection contract for details N...

Page 18: ...frigerant Contact your dealer for discarding the system air conditioner since it is required by law to collect transport and discard the refrigerant in accor dance with relevant local and national reg...

Page 19: ...3P201178 2B EM07A012 0705 HT...

Reviews: