background image

2e

ÈEEDEN08-204aËÍ

Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with the
ISO9001 standard. ISO9001 pertains to quality
assurance regarding design, development,
manufacturing as well as to services related to the
product. 

Daikin units comply with the European 
regulations that guarantee the safety of 
the product.

EEDEN08-20

4  • 0

1

/200

8 • C

opyrigh

©

 Dai

k

in

Pr

epare

d

 in Belgium

 by Lannoo

  (ww

w

.lann

oopr

int.

be)

, a c

o

m

p

any who

se c

o

nc

er

n fo

th

e enviro

nmon

t is s

e

t i

n

 the EMAS and ISO 140

01 sys

tem

s.

Re

spo

n

sib

le E

d

ito

r:

 Da

ik

in 

E

u

ro

pe N.

V.

, Za

ndvo

or

des

tra

a

300,

 B- 8400 Oos

tende

The present publication is drawn up by way of information only and
does not constitute an offer binding upon Daikin Europe N.V.. Daikin
Europe N.V. has compiled the content of this publication to the best
of its knowledge. No express or implied warranty is given for the
completeness, accuracy, reliability or fitness for particular purpose of
its content and the products and services presented therein.
Specifications are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct or indirect
damage, In the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted
by Daikin Europe N.V..

VRV

®

 products are not within the scope of the

Eurovent certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin
has had the intension to become a leader in the
provision of products that have limited impact
on the environment. This challenge demands
the eco design and development of a wide
range of products and an energy management
system, resulting in energy conservation and a
reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of the
environment.

Summary of Contents for VRSIII-S Series

Page 1: ...technical data Concealed ceiling unit FXMQ PVE air conditioning systems EEDEN08 204 2e...

Page 2: ...ecifications 3 2 Safety device settings 4 3 Options 4 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 8 6 Dimensional drawing centre of gravity 10 Dimensional...

Page 3: ...irect drive Piping connections Liquid OD Type Flare connection Diameter mm 6 35 9 52 9 52 9 52 9 52 9 52 Gas Type Flare connection Diameter mm 12 7 15 9 15 9 15 9 15 9 15 9 Drain Diameter mm VP25 I D...

Page 4: ...mum fuse amps MFA A 16 16 16 16 16 16 Full load amps FLA A 1 1 1 3 1 4 1 8 2 3 2 7 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where vo...

Page 5: ...443 NOTE 1 See the latest for the modification marks Model DUCT TYPE Item FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE High efficiency filter 65 KAF372AA56 KAF372AA80 KAF372AA160 90 K...

Page 6: ...ensor KRCS01 1B 7 Mounting plate for adapter PCB Note 2 3 KRP4A96 8 Central remote control DCS302CA61 8 1 Electrical box with earth terminal 3 blocks KJB311AA 9 Unified on off control DSC301BA61 9 1 E...

Page 7: ...5 4 1 5 2 4 5 5 6 4 6 5 9 4 6 6 0 4 4 6 1 3 7 33 0 3 8 3 6 4 5 4 1 5 2 4 5 5 6 4 6 5 8 4 5 5 9 4 3 6 0 3 7 35 0 3 8 3 6 4 5 4 1 5 2 4 5 5 6 4 6 5 7 4 5 5 8 4 3 5 9 3 6 37 0 3 8 3 6 4 5 4 1 5 2 4 5 5...

Page 8: ...6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 5 8 5 11 8 8 2 12 1 7 9 35 0 7 6 6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 3 8 4 11 6 8 1 11 9 7 8 37 0 7 6 6 4 9 0 7 3 10 5 8 3 11 0 8 4 11 2 8 3 11 4 8 0 11 7 7 7 39 0 7 6 6...

Page 9: ...8 5 8 5 8 5 5 3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6...

Page 10: ...9 5 0 4 1 12 7 12 7 12 5 12 1 11 7 10 9 7 0 6 0 13 1 13 1 12 5 12 1 11 7 10 9 9 0 7 9 13 5 13 3 12 5 12 1 11 7 10 9 11 0 9 8 14 0 13 3 12 5 12 1 11 7 10 9 13 0 11 8 14 1 13 3 12 5 12 1 11 7 10 9 15 0...

Page 11: ...ntrol box Arrow view B 2 According to any one of below 1 3 secure a space for service works such as checking and maintenance of control box and drain pumps etc FXMQ50 63 80P 3D060161 12 Drain hose acc...

Page 12: ...M10 9 Air suction flange 8 Air discharge flange 7 Power supply connection 6 Interunit wiring connection 5 Control box inside 4 Ground terminal in control box M4 3 Drain pipe connection VP25 O D 32 I...

Page 13: ...hatch 450mmx450mm Inspection hatch 450 Control box Control box Control box Inspection hatch 3 or more or less or more or more NOTES 1 Location of MANUFACTURE S LABEL Control box surface 2 Mount the a...

Page 14: ...VRV Systems Indoor Units 143 Indoor Units CONCEALED CEILING UNIT FXMQ PVE 6 Dimensional drawing centre of gravity 6 2 Centre of gravity FXMQ P 4D060438 MODEL NAME FXMQ40P FXMQ50 63 80P FXMQ100 125P...

Page 15: ...ts CONCEALED CEILING UNIT FXMQ PVE VRV Systems Indoor Units 144 7 Piping diagram FXMQ P 4D034245C Heat exchanger Fan Gas pipe connection port Liquid pipe connection port Filter Filter Electronic expan...

Page 16: ...250V R2T Thermistor liquid Wired remote control F2U Fuse T 5A 250V R3T Thermistor gas R1T Thermistor air F3U Fuse T 6 3A 250V R4T Thermistor discharge air SS1 Selector switch main sub F4U Fuse T 6 3A...

Page 17: ...hreshold hearing for continuous noise FXMQ50P Scale Air flow rate HH H L A 41 0 39 0 37 0 C 46 0 44 0 42 0 Discharge Suction 1m 2m Duct Duct 1 5m Microphone 4D060447 NOTES 1 Over All dB B G N is alrea...

Page 18: ...hreshold hearing for continuous noise FXMQ100P Scale Air flow rate HH H L A 43 0 41 0 39 0 C 49 0 46 0 44 0 Discharge Suction 1m 2m Duct Duct 1 5m Microphone 4D060449 NOTES 1 Over All dB B G N is alre...

Page 19: ...e value in this figure shows ESP in rating air flow Range of available air flow rate in HH rating EPS HH rating ESP L rating ESP HH min ESP L min ESP mmH2O mmH2O mmH2O mmH2O FXMQ80P 3D060459 External...

Page 20: ...ons are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related to the use and or inte...

Reviews: