![background image](http://html1.mh-extra.com/html/daikin/vkm100gmv1/vkm100gmv1_installation-manual_2459164019.webp)
English
17
VKM50
·80
·100GV1
3D048372-1
A1P
A2P
C1
·C2
F1U
F1U
F1UT
·
F2UT
HAP
HAP
K1R~K3R
K4R~K6R
K7R
M1D
M1F
M2F
R1T
R2T
R3T
R4T,R5T
S1Q
SS1
T1R
T2R
PRINTED CIRCUIT BOARD
PRINTED CIRCUIT BOARD
CAPACITOR (M1F, M2F)
FUSE ( B , 10A, 250V)(A1P)
FUSE ( B , 5A, 250V)(A2P)
THERMO SWITCH
(152
˚C)(M1F, M2F BUILT-IN)
LIGHT EMITTING DIODE
(SERVICE MONITOR-GREEN)(A1P)
LIGHT EMITTING DIODE
(SERVICE MONITOR-GREEN)(A2P)
MAGNETIC RELAY (M1F)(A1P)
MAGNETIC RELAY (M2F)(A1P)
MAGNETIC RELAY (M1D)(A1P)
MOTOR (DAMPER MOTOR)
MOTOR (SUPPLY AIR FAN)
MOTOR (EXHAUST AIR FAN)
THERMISTOR (INDOOR AIR)
THERMISTOR (OUTDOOR AIR)
THERMISTOR
(INLET AIR INTO COIL)
THERMISTOR
(LIQUID/GAS PIPE OF COIL)
LIMIT SWITCH
(DAMPER MOTOR)
SELECTOR SWITCH
(FOR ESPECIALLY USE)(A1P)
TRANSFORMER
(220-240V/22V)
TRANSFORMER
(220-240V/22V)
X1M
X2M
X3M
X17A,X19A
X20A
Y1E
TERMINAL BLOCK
(POWER SUPPLY)
TERMINAL BLOCK
(CONTROL)(A1P)
TERMINAL BLOCK
(CONTROL)
CONNECTOR
(RELAYING WIRE)
CONNECTOR
(RELAYING WIRE)
ELECTRONIC EXPANSION
VALVE
2. : FIELD WIRING
3.
IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED
INSTRUCTION MANUAL.
4.
IN CASE USING WIRING ADAPTER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTALLATION
MANUAL.
5.
WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FRESH UP CONTROL OPERATION CAN BE SELECTED BY
REMOTE CONTROLLER, IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.
6.
WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED OFF OR ON/OFF CONTROL OPERATION CAN BE
SELECTED BY REMOTE CONTROLLER, IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.
7.
DO NOT REMOVE THE SHORT CIRCUIT CONNECTORS OF X8A AND X9A, THE UNIT WILL NOT RUN IF THEY ARE
REMOVED.
8.
SS1(A1P) HAS ALREADY BEEN SET TO
“NOR.
” AT FACTORY SET. THE UNIT WILL NOT RUN IF THE SETTING ARE
CHANGED.
9.
SYMBOLS SHOW AS FOLLOWS. (PNK: PINK WHT: WHITE YLW: YELLOW ORG: ORANGE BLU:BLUE
BLK: BLACK RED: RED GRN: GREEN)
10.
USE COPPER CONDUCTORS ONLY.
: TERMINAL BLOCK,
: TERMINAL,
: CONNECTOR,
: SHORT CIRCUIT CONNECTOR
1.
Notes)
OPTIONAL ACCESSORIES
WIRED REMOTE CONTROLLER
SS1
Ry1
Ry2
Tes10
SELECTOR SWITCH
(MAIN/SUB)
ADAPTOR PC BOARD FOR WIRING
(KRP50-2)
MAGNETIC RELAY
(OPERATION/STOP)
MAGNETIC RELAY
(FOR HUMIDIFIER OPERATION)
TERMINAL BLOCK
(FOR EXTERNAL OUTPUT)
CONNECTOR FOR
OPTIONAL PARTS
X11A
X18A
CONNECTOR
(ADAPTER POWER
SUPPLY)(A1P)
CONNECTOR
(WIRING ADAPTER FOR
ELECTRICAL APPENDICES)(A2P)
,
WIRING DIA
GRAM
Note) 4
Note) 8
Note) 7
POWER SUPPLY
220-240V
~
50Hz
ADAPTER PC BOARD FOR WIRING
(OPTIONAL ACCESSORIES)
EXTERNAL OUTPUT
TERMINALS
CONTACT
CAPACITY
Note) 6
INPUT FROM OUTSIDE
Note) 3
TO CONNECTION WIRING AND
CENTRAL REMOTE
CONTROLLER UNIT
WIRED REMOTE CONTROLLER
(OPTIONAL ACCESSORIES)
Note) 5
INPUT
FROM
OUTSIDE
CONTROL BOX
01_3P130768-1A_En.fm Page 17 Wednesday, March 23, 2005 7:00 PM