1.0 INTRODUCTION
This manual applies to Water Cooled Self Contained Units, Models UCQ60 to UCQ940
.
This manual provides
specific instructions for installation, owner maintenances, and troubleshooting.
Due to continuous product improvement and enhancements, the information provided is subject to change without
notice.
1.1 NOMENCLATURE
1.2 DESCRIPTION OF UNIT
The water cooled self-contained air conditioner is the ultimate solution addressing the energy efficiency, reliability,
indoor air quality, and sound concerns for commercial, industrial and institutional buildings. Daikin offers a simple
system design, increases system redundancy by providing individual air conditioning systems per floor, lowers
maintenance costs, eases operation and maintenance, and provides the lowest life cycle cost available. Based on
these features, the self-contained unit has surpassed the traditional chillers, air handlers and rooftop systems and is
now the system of choice.
Models UCQ60 to UCQ940 are factory assembled, refrigerant charged and tested water-cooled packaged air
conditioning units designed for ducted or free blow applications.
Each unit contains:
• Single or multiples hermetic scroll compressors
• Water cooled condensers
• Single or multi-circuit evaporator
• Thermal expansion valves
• Interconnecting refrigerant piping
• Double inlet centrifugal supply fan
• Belt driven
• Fan motor
• R29 or G3 Filters
• All necessary operating and required safety
controls to operate the unit.
All rigging, installation, power and control wiring external to the unit, and condenser water and condensate piping
are under the responsibility of the installer.
Unit Category
UC: Water Cooled
Generation
A- 1st Generation (1 inch PU panel)
A2 -1st Generation (2 inch PU panel)
Refrigerant
Q: R410A
Capacity (MBH)
90: 90MBH
External Static Pressure
D: With Plenum, 0Pa
L: Standard, 250Pa
H: Maximum,375Pa
Q
90
A
P
E
L
UC
Y1
Additional Features
Blank: Without pressure gauge; standard condenser outlet
P: With pressure gauge; standard condenser outlet
L: Without pressure gauge; custom made: left condenser outlet
M: With pressure gauge; custom made: left condenser outlet
R: Without pressure gauge; custom made: right condenser outlet
M: With pressure gauge; custom made: left condenser outlet
Controller Description
B: Basic Control Box with Terminal Block
E: DOL Starter with Electronic Controller
S: Soft Starter with Electronic Controller
Power
Y1: 380~415V, 3Ph, 50Hz
Summary of Contents for UCQ0060
Page 13: ...13 5 1 UNIT DIMENSION 5 1 1 Outline UCQ60A D L...
Page 14: ...14 5 1 2 Outline UCQ90A D L...
Page 15: ...15 5 1 3 Outline UCQ140A D L...
Page 16: ...16 5 1 4 Outline UCQ180A D L...
Page 17: ...17 5 1 5 Outline UCQ240A L...
Page 18: ...18 5 1 6 Outline UCQ280A L...
Page 19: ...19 5 1 7 Outline UCQ320A L...
Page 20: ...20 5 1 8 Outline UCQ360A L...
Page 21: ...21 5 1 9 Outline UCQ400 520A L...
Page 22: ...22 5 1 10 Outline UCQ570A L...
Page 23: ...23 5 1 11 Outline UCQ710A L...
Page 24: ...24 5 1 12 Outline UCQ870A L...
Page 25: ...25 5 1 13 Outline UCQ940A L...
Page 29: ...29 5 6 Fan Curve 5 6 1 Fan Curve AT 9 9 Model UCQ60 UCQ90...
Page 30: ...30 5 6 2 Fan Curve AT 15 15 Model UCQ140 UCQ180 UCQ240...
Page 31: ...31 5 6 3 Fan Curve AT 18 18 Model UCQ280...
Page 32: ...32 5 6 4 Fan Curve ADH 450 Model UCQ320 UCQ360 UCQ710...
Page 33: ...33 5 6 5 Fan Curve ADH 500 Model UCQ400 UCQ520 UCQ870 UCQ940...
Page 34: ...34 5 6 6 Fan Curve ADH 560 Model UCQ570...
Page 37: ...37 6 1 WIRING DIAGRAM 6 1 1 Wiring Diagram UCQ60AE UCQ90AE UCQ140AE UCQ180AE...
Page 38: ...38 6 1 2 Wiring Diagram UCQ240AE UCQ280AE...
Page 39: ...39 6 1 3 Wiring Diagram UCQ320AE UCQ360AE...
Page 40: ...40 6 1 4 Wiring Diagram UCQ400AE UCQ520AE...
Page 41: ...41 6 1 5 Wiring Diagram UCQ570AE...
Page 42: ...42 6 1 6 Wiring Diagram UCQ710AE UCQ870AE...