 WARNING

 Installation and maintenance should be performed by 
qualified persons who are familiar with local code 
and  regulation, and experienced with this type of 
appliance.
 All field wiring must be installed in accordance with 
the national wiring regulation.
 Ensure that the rated voltage of the unit corresponds 
to that of the name plate before commencing wiring 
work according to the wiring diagram.
 The unit must be GROUNDED to prevent possible 
hazard due to insulation failure.
 All electrical wiring must not touch the refrigerant 
piping, or any moving parts of the fan motors.
 Confirm that the unit has been switched OFF before 
installing or servicing the unit.
 Disconnect from the main power supply before 
servicing the air conditioner unit.
 DO NOT pull out the power cord when the power is 
ON. This may cause serious electrical shocks which 
may result in fire hazards.
 Keep the air-conditioner units, power cable and 
transmission wiring, at least 1m from TVs and radios, 
to prevent distorted pictures and static. (Depending on 
the type and source of the electrical waves, static may 
be heard even when more than 1m away).

!

 CAUTION

Please take note of the following important points 
when installing.

 

Do not install the unit where leakage of flammable 
gas may occur.

 If gas leaks and accumulates around the unit, it 
may cause fire ignition.

Ensure that drainage piping is connected properly.

 If the drainage piping is not connected properly, it 
may cause water leakage which will dampen the 
furniture.

Do not overcharge the unit.

This unit is factory pre-charged. 
 Overcharge will cause over-current or damage to 
the compressor.

 

Ensure that the unit’s panel is closed after service 
or installation.

 Unsecured panels will cause the unit to operate 
noisily.

 

Sharp edges and coil surfaces are potential locations 
which may cause injury hazards.
Avoid from being in contact with these places.

 

Before turning off the power supply, set the remote 
controller’s ON/OFF switch to the “OFF” position 
to prevent the nuisance tripping of the unit.

 If this is 

not done, the unit’s fans will start turning automatically 
when power resumes, posing a hazard to service 
personnel or the user.
 

Do not operate any heating apparatus too close to 
the air conditioner unit.
 Don

ʼ

t use joined and twisted wires for incoming 

power supply.
 The equipment is not intended for use in a potentially 
explosive atmosphere.

IMPORTANT

ENGLISH

Important information regarding the refrigerant used

 

This product contains fluorinated greenhouse gases. 
Do not vent gases into the atmosphere.

GWP 

(1) 

value: 

1773

.

85

(1)

 GWP = global warming potential

The refrigerant quantity is indicated on the unit name 
plate.
Periodical inspections for refrigerant leaks may be required 
depending on European or local legislation. Please contact 
your local dealer for more information.

SAFETY PRECAUTIONS

INSTALLATION MANUAL

This manual provides the procedures of installation to ensure a safe and good standard of operation for the air 
conditioner unit.
Special adjustment may be necessary to suit local requirements.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for 
commercial use by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

NOTICE

Disposal Requirement

Dismantling of the unit, treatment of the refrigerant, oil and other parts must be done in accordance with the 
applicable legislation.

Original Instruction

1 IM-RTA-0612(4)DK-EN.indd   1

1 IM-RTA-0612(4)DK-EN.indd   1

6/26/14   3:18:16 PM

6/26/14   3:18:16 PM

Refrigerant type:  R407C

Summary of Contents for UAT100A

Page 1: ...Package Units Manuel D installation Conditionneurs D air En Toiture Installationshandbuch Kompaktanlage F r Dachmontage Manuale Di Installazione Unit A Pacchetto Per Installazione Sul Tetto Manual De...

Page 2: ...CVR IM RTA 0612 4 DK EN indd 2 CVR IM RTA 0612 4 DK EN indd 2 6 26 14 3 05 50 PM 6 26 14 3 05 50 PM...

Page 3: ...0 150 150 20 668 24 125 125 24 208 224 208 668 224 208 224 60 150 150 150 150 150 150 60 1020 10 Supply air duct flange 21 3 Holes 51 1300 51 173 1020 107 265 265 1000 4 15X25 Mtg holes B 1342 1300 13...

Page 4: ...T80 100A only 9 9 C A 2 Down flow A B C O 1670 1200 H P 1800 1330 1990 1744 123 51 123 51 46 25 1990 2032 2082 235 235 4 15X25 Mtg holes 46 25 B B 25 25 2032 15 72 200 200 200 200 200 200 200 200 72 1...

Page 5: ...2 1990 264 294 51 51 46 25 25 15 91 10 1990 2032 2082 46 25 1782 2032 235 235 25 25 15 2032 25 200 200 200 200 200 200 200 200 91 10 10 46 46 140140 372 359 120120 59 5 59 5 86 10 180 180 180 180 180...

Page 6: ...SER AIR INLET 3180 3100 3148 80 100 660 1974 1650 210 2252 782 SUPPLY AIR 62 892 526 RETURN AIR DRAIN 1 RETURN AIR SUPPLY AIR 516 1220 516 DETAIL A 27 5 15 22 5 A X Y 360 1730 1130 420 1800 1080 Y X C...

Page 7: ...ore turning off the power supply set the remote controller s ON OFF switch to the OFF position to prevent the nuisance tripping of the unit If this is not done the unit s fans will start turning autom...

Page 8: ...ocation For Installation Install the unit in such way that air distributed by the unit cannot be drawn in again as in the case of short circuit of discharge air Allow sufficient space for maintenance...

Page 9: ...m Spreader Bar Chain Lifting Holes for shackle 4 corners Chain Hanger Bracket A 70mm B 2C C 2X ESP INSTALLATION OF THE UNIT 1 5 Drain piping A 1 FPT condensate drain fitting is provided The drain pipe...

Page 10: ...ce Condenser inlet Condenser inlet min clearance 1500 1000 Electrical control circuit compressor service 300 300 700 1000 UAT Y P 150 200A 500 min clearance UAT Y P 250 300 360 420A Electrical control...

Page 11: ...Remove duct flange Remove duct flange Re install supply air cover Re install fan assy Remove Remove low cover Remove supply air cover 2 Additional casing leg Accessory parts 1 Additional side inlet co...

Page 12: ...H x THICKNESS mm 840 x 667 x 1 1370 x 735 x 1 860 x 505 600 x 4 HEAT PUMP R407C MODEL UATP60A UATP80A UATP100A UATP120A UATP150A REFRIGERANT R407C REFRIGERANT CHARGE kg 4 6 4 6 5 9 5 6 3 9 x 2 EVAPORA...

Page 13: ...RRENT LRA COMP A 81 x 2 118 x 2 174 x 2 175 215 215 x 2 HEAT PUMP R407C MODEL UATYP60A UATYP80A UATYP100A UATYP120A UATYP150A POWER SUPPLY V ph Hz 400 3N 50 VOLTAGE RANGE V 380 415 MAX CONTINUOUS CURR...

Page 14: ...NOTE While installing the circuit breaker onto the unit make sure that the screws do not damage the components e g coil inside of the unit The circuit breaker also can be installed without attaching t...

Page 15: ...F1 51F1 47 N T S R N T S R 52C 47 51F1 52F 51C2 TB2 3 52C2 52C1 51C1 X1 X2 PCB 52F2 52F3 TB1 47 F1 T1 51C TB1 F1 X1 X2 X3 Terminal Block for power supply wires Arrangement of terminal block for contro...

Page 16: ...g Only Unit Cooling Mode For Heat Pump Model Outdoor temp C DB Indoor temp C WB Indoor temp C WB 9 15 27 18 5 15 20 10 0 5 20 30 10 25 Indoor temp C DB Heat pump Heat Pump Unit Only Outdoor temp C WB...

Page 17: ...lean the filter at least once every 2 weeks Or more frequently if neccesary Filter Position The filters are mounted in front of the indoor heat exchanger Air filter special order or field supply UAT Y...

Page 18: ...r reset circuit breaker Power supply wiring phase incorrect Modify the wiring phase Compressor does not operate in 3 min after unit has started Protection against frequent starting Wait for 3 min for...

Page 19: ...CVR IM RTA 0612 4 DK EN indd 3 CVR IM RTA 0612 4 DK EN indd 3 6 26 14 3 05 50 PM 6 26 14 3 05 50 PM...

Page 20: ...ale Il fabbricante mantiene il diritto di cambiare qualsiasi specificazione e disegno contenuti qui senza precedente notifica En caso de conflicto en la interpretaci n de este manual y en su traducci...

Page 21: ...i Yakac k D 100 Kuzey Yanyol Caddesi No 49 1 2 Kartal stanbul Head office Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan Tokyo office JR Shinagawa East Bldg 2 18 1 Konan Minato k...

Reviews: