background image

www.DaikinApplied.com 

IM 745-3

Models THCH08, THCH10 and THCH12 

(Basic Unit Only)

Figure 9: (115V / 1Ph / 60Hz), (208-230V / 1Ph / 60Hz)

H

YELLOW

SHF:  FAN SPEED SUPER HIGH

BLACK

YELLOW

LF: FAN SPEED LOW

M1,M2:  FAN MOTOR

FIELD WIRING

NOTE:

HF:  FAN SPEED HIGH

MF:  FAN SPEED MEDIUM

G/Y

RED

G/Y

BLUE

RED

L

SOURCE

POWER

N

FAN SPEED

SWITCH

SHF

HF

ORANGE

BROWN

M2

BLACK

G/Y

BLACK

ORANGE

BROWN

L

M

MF

LF

M1

BLACK

MAIN SWITCH

G

G/Y

WHITE

BLACK

G/Y: GREEN/YELLOW

BLACK

G/Y: GREEN/YELLOW

FIELD WIRING

M1,M2:  FAN MOTOR

LF: FAN SPEED LOW

NOTE:

POWER

SOURCE

MAIN SWITCH

BLACK

WHITE

MF:  FAN SPEED MEDIUM
HF:  FAN SPEED HIGH

SHF:  FAN SPEED SUPER HIGH

M2

G/Y

RED

BLUE

N

YELLOW

BROWN

G/Y

BLACK

SWITCH

FAN SPEED

H

M

L

LF

G/Y

L

RED

SHF

ORANGE

MF

YELLOW

HF

BROWN

M1

BLACK

ORANGE

BLACK

Figure 10: (220V / 1Ph / 50Hz)

H

YELLOW

SHF:  FAN SPEED SUPER HIGH

BLACK

YELLOW

LF: FAN SPEED LOW

M1,M2:  FAN MOTOR

FIELD WIRING

NOTE:

HF:  FAN SPEED HIGH

MF:  FAN SPEED MEDIUM

G/Y

RED

G/Y

BLUE

RED

L

SOURCE

POWER

N

FAN SPEED

SWITCH

SHF

HF

ORANGE

BROWN

M2

BLACK

G/Y

BLACK

ORANGE

BROWN

L

M

MF

LF

M1

BLACK

MAIN SWITCH

G

G/Y

WHITE

BLACK

G/Y: GREEN/YELLOW

BLACK

G/Y: GREEN/YELLOW

FIELD WIRING

M1,M2:  FAN MOTOR

LF: FAN SPEED LOW

NOTE:

POWER

SOURCE

MAIN SWITCH

BLACK

WHITE

MF:  FAN SPEED MEDIUM
HF:  FAN SPEED HIGH

SHF:  FAN SPEED SUPER HIGH

M2

G/Y

RED

BLUE

N

YELLOW

BROWN

G/Y

BLACK

SWITCH

FAN SPEED

H

M

L

LF

G/Y

L

RED

SHF

ORANGE

MF

YELLOW

HF

BROWN

M1

BLACK

ORANGE

BLACK

W

IrIng

 D

Iagrams

Control Wiring Schematics

Figure 11: Heating/Cooling 2-Pipe With Automatic Changeover

WHT

16

CLG

BLU

HTG

RED

BLK

RED

WHT

WHT

TCI

ORG

C/O

V

HTG

CLG

TCI

V

C/O

Wire No.
Wire Color
Wire Connector
Wire Connector
Field Connector
Cooling
Heating
Thermostat
Valve
Change over Switch

(Manual or Auto)

BLK

Legend

Figure 12: Heating/Cooling 4-Pipe With Sequencing Thermostat

CLG

BLU

HTG

RED

BLK

BLK

HTG

CLG

WHT

WHT

WHT

TCI

ORG

V

V

WHT

16

HTG

CLG

TCI

V

C/O

Wire No.
Wire Color
Wire Connector
Wire Connector
Field Connector
Cooling
Heating
Thermostat
Valve
Change over Switch

(Manual or Auto)

Legend

Summary of Contents for THC02

Page 1: ...Installation and Maintenance Manual IM 745 3 Group Fan Coil Part Number 668708901 Date October 2018 Ceiling Concealed Fan Coil Unit Models THC02 THC03 THC04 THC06 THC08 THC10 THC12...

Page 2: ...t should be unpacked in the presence of the agent so that the extent of the damage or loss can be determined The carri er s agent will make an inspection report and a copy will be given to the consign...

Page 3: ...is designed to be concealed in the ceiling Installation and maintenance should be performed by qualified personnel who are familiar with local codes and regulations and experi enced with this type of...

Page 4: ...ed and removable for cleaning It may be necessary to manually fill the trap at system start up or to run the unit for sufficient time to build a condensate seal The condensate trap and condensate pipi...

Page 5: ...www DaikinApplied com 5 IM 745 3 Wiring Diagrams Model C3H 02 12EA 208 230V 60Hz Model C3H 02 12JA 277V 60Hz...

Page 6: ...OR FIELD WIRING MAIN SWITCH G Y BLACK WHITE BLUE N L FAN SPEED SWITCH H RED SHF YELLOW HF M L BROWN MF ORANGE LF G Y BLACK M BLACK Figure 8 220V 1Ph 50Hz L G Y GREEN YELLOW FIELD WIRING LF FAN SPEED L...

Page 7: ...PEED MEDIUM G Y RED G Y BLUE RED L SOURCE POWER N FAN SPEED SWITCH SHF HF ORANGE BROWN M2 BLACK G Y BLACK ORANGE BROWN L M MF LF M1 BLACK MAIN SWITCH G G Y WHITE BLACK G Y GREEN YELLOW BLACK G Y GREEN...

Page 8: ...ot Water Connection 3 4 FPT Main Drain Connection 3 4 O D 8 82 Unit w o Plenum 18 35 Unit w o Plenum Optional LV 3SP Jbox 7 73 H x 6 54 W x 3 38 D always located on the end opposite the coil connectio...

Page 9: ...ssed air or water They can be vacuumed or brushed with a soft brush CAUTION Water coils exposed to freezing temperatures should be drained or anti freeze should be added to the water circuit to avoid...

Page 10: ...new air filter The cooling or heating function fails The electric control valve of unit is not started Start the electric control valve of unit The circulating pump is not started As a result the cold...

Page 11: ...Driver Indicator Light Failure Description Suggested Elimination Method 1 Motor overcurrent protection Check whether there is open circuit or short circuit on the motor lead 3 Over voltage protection...

Page 12: ...ndard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Applied representative for warranty details Refer to Form 933 430285Y To find your local Daikin Applied...

Reviews: