What is COP?
An air conditioner's COP (coefficient of performance) indicates how
efficiently it uses energy. A high COP means high energy efficiency.
COP =
Capacity (W)
Power consumption (W)
Main features
Main features
ntelligent
technologies
High energy efficiency through advanced
technologies delivers high COP.
deal
environment
Convenient features to create your
ideal environment
* During rated capacity operation of 5 indoor units
(2.0 + 2.0 + 2.0 + 2.0 + 2.0 kW class).
High energy efficiency
COP
4.58
3.65
Cooling operation Heating operation
5MXS100LVMA
Pulse Amplitude Modulation (PAM) control
reduces energy loss by controlling the amount
of switching on/off of the converter.
50
0
30
60
90
120
60
70
80
90
Small load
Large load
Low capacity
High capacity
Reluctance DC Motor
Conventional
DC motor
More than 20%
AC motor
Rotational speed (rps)
Motor efficiency (%)
Loss
Loss
Power supply
POWER
Power
factor
Converter
efficiency
Inverter
efficiency
Swing compressor
Reluctance DC motor
PAM control
Daikin energy-efficient technologies
The swing compressor can reduce
operational vibration and sound
because its piston moves smoothly
inside the compressor.
Swing bush
Integral piston of
blade and roller
Refrigerant gas
Reluctance DC motor
Swing compressor
Thanks to its smooth
rotation, the swing
compressor decreases
friction and vibration. It also
prevents the leakage of
refrigerant gas during
compression. These
advantages provide quiet
and efficient operation.
The use of a Reluctance DC motor with
neodymium magnets
*1
for our
compressors has improved motor
efficiency by more than 20% compared
to AC motors. The high torque
*2
and
stronger magnetic force produced is
beneficial particularly at low load
conditions.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite
magnet.
*2. The torque created by the change in power between the iron and magnet parts.
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory.
Neodymium magnets are used
in the pink-coloured area.
1
2
3
Indoor unit
During cooling operation
Set temp.
Temp.
Time
Starts
Too cool
Not cool
Non-inverter air conditioners can
only perform simple on/off
operation. They start operation
when the temperature rises and
stop when the room reaches the
set temperature and then switch to
low-capacity operation. As a result,
inverter air conditioners are more
energy efficient and comfortable
than non-inverter air conditioners.
Non-inverter type
DC inverter type
* This diagram is a representation for illustrative purposes only.
Quiet operation
Comfortable temperature control
Wide operation range
Outdoor unit
Rustling of leaves
Quiet library
Midnight in the suburbs
Quiet office
22 dB (A) is so quiet you can even hear whispers
50
40
30
20
(dB(A))
22
dB (A)
Heat pump type
4MXS80
With Super Multi NX, cooling operation is possible even during lower
outdoor temperatures.
Note: This information is for heat pump type.
Super Multi NX achieves a quiet sound level of 43 dB (A) during Outdoor Unit Quiet Operation or Night Quiet
Mode of the 3MXS52 during cooling operation.
Note: Capacity may decrease when quiet functions are selected.
Super Multi NX offers the quiet sound level of 22 dB (A) during
Indoor Unit Quiet Operation of the FTXS20/25 during cooling
operation.
Note: Capacity may decrease when quiet functions are selected.
-10
0
10
20
30
40
50
-20
-10
0
10
20
15.5
°
C WB
Heating
46
°
C DB
Cooling
-10
°
C DB
–15
°
C WB
Outdoor temperature (
°
C DB)
Outdoor temperature (
°
C WB)