Cooling only use
Options
Control system
Indoor unit
Outdoor unit
No.
1
2
3
4
5
6
7
8
9
10
11
12
Wired remote controller*
1
Wired remote controller
cord
5-room centralised controller*
2
Wiring adaptor for time clock/remote controller*
3
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*
4
Photocatalytic deodorising filter with frame*
5
Photocatalytic deodorising filter without frame*
5
Air-purifying filter with frame*
6
Air-purifying filter without frame*
6
Wireless remote controller loss prevention chain
Suction grille
Insulation kit for high humidity
Length 3 m (shielded wire)
Length 8 m (shielded wire)
C(F)DK(X)S25-50C C(F)DK(X)S60C
KRC72
KRP413AB1S
KAF970A46
—
—
—
—
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
KKF917A4
No.
1
2
3
4
Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
Note: * Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
KPW945A4
KPW5E112
Wall-mounted type
Wall-mounted type
Duct-connected type
Floor-standing
type
Floor/ceiling-
suspended dual type
Duct-connected type
Floor-standing type
Floor/ceiling-suspended dual type
Item
—
—
—
—
—
—
KAF968A42
KDGF19A45
KDT25N50
KDT25N32
KDT25N63
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 1 piece for 1 unit.
5-room centralised
controller
KRC72
Remote controller loss
prevention chain
KKF917A4
Air direction adjustment grille
KPW945A4
Drain plug
KKP937A4
Central remote controller
DCS302CA61
Unified on/off controller
DCS301BA61
Schedule timer
DST301BA61
Item
Decoration panel
Fresh air intake kit
Sealing member of air discharge outlet
Panel spacer
Wiring adaptor for electrical appendices
*
2
Installation box for adaptor PCB
Replacement long-life filter
Remote controller
Wired type
*
1
Heat pump use
Wireless type
Remote sensor (for indoor temperature)
Adaptor for wiring
*
2
Notes: *1. Wiring for wired remote controller should be obtained locally.
*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
KDDQ44XA60
KDBH44BA60
KDBQ44BA60A
KRP4AA53
KRP1BA57
KRP1BA101
KRCS01-1B
BYFQ60B8W1
KAFQ441BA60
BRC1C61
BRC7E530W
BRC7E531W
Compact multi flow ceiling-mounted cassette type
1
3
2
4
5
6
7
8
9
10
No.
CDK(X)S25/35EA
BRC944B2
BRCW901A03
BRCW901A08
—
—
—
Titanium apatite photocatalytic
air-purifying filter
KAF970A46
Direct installation type
Specifications
Options
Notes: *1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.
*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*3. Time clock and other devices should be obtained locally.
*4. Filter is a standard accessory. It should be replaced approximately every 3 years.
*5. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
This accessory is only required if the original filter is damaged or lost, etc.
*6. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
KKF917A4
KKF910A4
KKF910A4
Floor/ceiling-suspended dual type
FLXS25BVMA
126 (268)
153 (325)
37/31/28
37/31/29
53
53
FLXS35GVMA
143 (304)
163 (346)
38/32/29
39/33/30
54
55
FLXS50GVMA
190 (402)
202 (427)
47/39/36
46/35/33
63
62
FLXS60GVMA
200 (424)
213 (452)
48/41/39
47/37/34
64
63
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
Liquid (flare)
Gas (flare)
Drain
Cooling
Heating
Cooling
Heating
/s
(cfm)
dB (A)
dB (A)
mm
kg
mm
ø12.7
16
ø9.5
17
1 phase, 220-240 V/220-230 V, 50/60 Hz
Almond white
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
ø6.4
ø18.0
Both liquid and gas pipes
Model name
Power supply
Front grille colour
Airflow rate
(H)
Sound level
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping
connections
Heat insulation
Compact multi flow ceiling-mounted cassette type
Note:
*
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Model name
Power supply
Airflow rate
(H)
Sound level*
(H/L)
Sound power
level (H)
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping
connections
Heat insulation
/s
(cfm)
dB (A)
dB (A)
mm
kg
mm
Model
Colour
Dimensions (H x W x D)
Weight
mm
kg
Panel
(option)
FFQ35BV1B
167 (353)
32/25
49
FFQ50BV1B
200 (424)
36/27
53
FFQ60BV1B
250 (530)
41/32
58
FFQ25BV1B
150 (318)
29.5/24.5
46.5
FFQ35BV1B
167 (353)
167 (353)
32/25
32/25
49
49
FFQ50BV1B
200 (424)
200 (424)
36/27
36/27
53
53
FFQ60BV1B
250 (530)
250 (530)
41/32
41/32
58
58
FFQ25BV1B
150 (318)
150 (318)
29.5/24.5
29.5/24.5
46.5
46.5
Cooling only
Heat pump
1 phase, 220-240 V, 50 Hz
2 steps
Microcomputer control
286 x 575 x 575
17.5
ø6.4
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
BYFQ60B8W1
White
2.7
ø9.5
ø12.7
ø9.5
ø12.7
—
—
—
55 x 700 x 700
Cooling
Heating
Measurement conditions
1. Cooling operation data is based on the following conditions: indoor temp. 27
°
CDB, 19
°
CWB; outdoor temp. 35
°
CDB; piping length 5 m.
2. Heating operation data is based on the following conditions: indoor temp. 20
°
CDB; outdoor temp. 7
°
CDB, 6
°
CWB; piping length 5 m.
3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Wired remote
controller
BRC944B2
No.
1
2
Item
Air direction adjustment grille
Drain plug
3MXS52L
3MKS58L
3MXS68L
3MKS68L
4MXS80L
4MKS80L
5MXS100L 5MKS100L
KKP937A4*
1
KKP945A4*
2