English
Indoor Unit Installation Drawings
INTELLIGENT EYE sensor
CAUTION
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
• Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.
A
C
Wireless
remote
controller
D
Remote
controller holder
Before screwing the remote
controller holder to the wall,
make sure that control
signals are properly
received by indoor unit.
Fixing screws for remote
controller holder
(field supply: M3 × 20L)
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
INTELLIGENT EYE
sensor
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Caulk
pipe hole
gap
with putty.
Mounting
plate
Clip
Mark (rear side)
Bottom frame
Front grille
How to attach the indoor unit
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
30mm or more
from ceiling
Front panel
50mm or more from walls
(on both sides)
Titanium apatite photocatalytic
air-purifying filter (2)
A
Mounting plate
Screws
(field supply: M4 × 25L)
B
Titanium apatite
photocatalytic
air-purifying filter
Filter frame
Air filter
Tab
Air filters
Screws
(M4 × 16L)
01_EN_3P266962-2A.fm Page 3 Thursday, October 28, 2010 9:12 AM