Indoor Unit Installation Drawings 

INTELLIGENT EYE sensor

CAUTION

• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

• Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.

A

 C
Wireless 
remote 
controller

 D  
Remote 
controller holder

Before screwing the remote 
controller holder to the wall, 
make sure that control 
signals are properly 
received by indoor unit.

Fixing screws for remote 
controller holder 
(field supply: M3 × 20L)

Service lid

Opening service lid

Service lid is opening/closing type.

Opening method

1) Remove the service lid screws.
2) Pull out the service lid diagonally 

down in the direction of the arrow.

3) Pull down.

INTELLIGENT EYE 
sensor

Wrap the insulation pipe with 
the finishing tape from bottom 
to top.

Cut thermal insulation 
pipe to an appropriate 
length and wrap it with 
tape, making sure that no 
gap is left in the insulation 
pipe’s cut line.

Caulk 
pipe hole 
gap 
with putty. 

Mounting
plate

Clip

Mark (rear side)

Bottom frame

Front grille

How to attach the indoor unit

Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.

How to remove the indoor unit

Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.

The mounting plate 
should be installed on a 
wall which can support the 
weight of the indoor unit.

30mm or more 
from ceiling

Front panel

50mm or more from walls 
(on both sides)

Titanium apatite photocatalytic 
air-purifying filter (2)

A

Mounting plate

Screws 
(field supply: M4 × 25L)

B

Titanium apatite 
photocatalytic 
air-purifying filter

Filter frame

Air filter

Tab

Air filters

Screws
(M4 × 16L)

01_EN_3P266962-2A.fm  Page 3  Thursday, October 28, 2010  9:12 AM

Summary of Contents for Super Multi NX FTXS20J2V1B

Page 1: ...ol Italiano Portugues T rk e Installation manual Installationsanleitung Manuel d installation Montagehandleiding Manual de instalaci n Manuale d installazione Manual de Instala o MODELS FTXS20J2V1B FT...

Page 2: ...25J2V1B FTXS35J2V1B FTXS42J2V1B FTXS50J2V1B DAIKIN INDUSTRIES LTD Shinri Sada Manager Quality Control Department Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC DAIKIN TCF 015 N4 09 2...

Page 3: ...tween the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper positioning of the control box lid may result in electric shocks fire or over heatin...

Page 4: ...e or sound 9 no laundry equipment is located 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find the site where remote controller signals are properly received...

Page 5: ...from bottom to top Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty Mounting...

Page 6: ...lle there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand When there is no work space because the unit is close...

Page 7: ...through the notched part in the figure 3 Replace the electrical wiring cover as it was and pull the harness around as shown in the figure Removal methods of metal plate electrical wiring cover 1 Remov...

Page 8: ...Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations O...

Page 9: ...erature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid...

Page 10: ...oor unit through the feed through wall hole and then through the back of the indoor unit Pull them through the front side Bend the ends of tie wires upward for easier work in advance If the inter unit...

Page 11: ...left side left back or left bottom piping Insert the drain hose to this depth so it won t be pulled out of the drain pipe Right bottom piping Right back piping Bind coolant pipe and drain hose togeth...

Page 12: ...our some water into the drain pan to check the water flows smoothly 3 When drain hose requires extension obtain an extension hose commercially available Be sure to thermally insulate the indoor sectio...

Page 13: ...If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air c...

Page 14: ...1101 HT 3P266962 2A M10B169 Two dimensional bar code is a code for manufacturing 00_CV_3P266962 2A fm Page 2 Tuesday September 21 2010 9 05 AM...

Reviews: