Indoor Unit Installation

1.

Installing the mounting plate

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.

1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring 

points on the wall.

2) Secure the mounting plate to the wall with screws.

Recommended mounting plate retention spots and dimensions 

2.

Boring a wall hole and installing wall embedded pipe

• For walls containing metal frame or metal board, be sure to use a wall 

embedded pipe and wall cover in the feed-through hole to prevent possible 
heat, electrical shock, or fire.

• Be sure to caulk the gaps around the pipes with caulking material to prevent 

water leakage.

1) Bore a feed-through hole of 65mm in the wall so it has a down slope toward 

the outside.

2) Insert a wall pipe into the hole.

3) Insert a wall cover into wall pipe.

4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole 

gap with putty.

3.

Inter-unit wiring

1) Open the front panel, then remove the service lid. 

2) Pass the inter-unit wire from the outdoor unit through the feed-

through wall hole and then through the back of the indoor unit. Pull 
them through the front side.  Bend the ends of tie wires upward for 
easier work in advance. (If the inter-unit wire ends are to be stripped 
first, bundle wire ends with adhesive tape.)

3) Press the bottom frame of the indoor unit with both hands to set it on 

the mounting plate hooks. Make sure the wires do not catch on the 
edge of the indoor unit.

unit: mm

Liquid pipe end

Drain hose position

Through the wall 
hole 

φ

65mm

* The removed pipe port cover can be 

kept in the mounting plate pocket.

Gas pipe end

Bilt size: M10

Place a leveler on raised tab.

Recommended mounting 
plate retention spots. 
(5 spots in all)

Bilt size: M10

φ

65

φ

65

44.5

45.5

295

Use tape measure 
as shown. 
Position the end 
of a tape measure 
at    .

115

56.5

147.5

450

103

400

200

44.5

60.5

45.5

175.5

Keep here the piece cut out 
from the unit for piping.

60.5

61

149

278.5

50

800

36

Removed pipe 
port cover 

A

Mounting plate

Inside

Outside

Caulking

Wall embedded pipe 
(field supply)

Wall hole cover
(field supply)

Wall embedded pipe 
(field supply)

φ

65

Hang indoor unit’s hook here.

Inter-unit wire

Mounting plate

A

When stripping the 
ends of inter-unit wire 
in advance, bind right 
ends of wires with 
insulating tape.

01_EN_3P266962-2A.fm  Page 8  Thursday, October 28, 2010  9:12 AM

Summary of Contents for Super Multi NX FTXS20J2V1B

Page 1: ...ol Italiano Portugues T rk e Installation manual Installationsanleitung Manuel d installation Montagehandleiding Manual de instalaci n Manuale d installazione Manual de Instala o MODELS FTXS20J2V1B FT...

Page 2: ...25J2V1B FTXS35J2V1B FTXS42J2V1B FTXS50J2V1B DAIKIN INDUSTRIES LTD Shinri Sada Manager Quality Control Department Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC DAIKIN TCF 015 N4 09 2...

Page 3: ...tween the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper positioning of the control box lid may result in electric shocks fire or over heatin...

Page 4: ...e or sound 9 no laundry equipment is located 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find the site where remote controller signals are properly received...

Page 5: ...from bottom to top Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty Mounting...

Page 6: ...lle there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand When there is no work space because the unit is close...

Page 7: ...through the notched part in the figure 3 Replace the electrical wiring cover as it was and pull the harness around as shown in the figure Removal methods of metal plate electrical wiring cover 1 Remov...

Page 8: ...Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations O...

Page 9: ...erature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid...

Page 10: ...oor unit through the feed through wall hole and then through the back of the indoor unit Pull them through the front side Bend the ends of tie wires upward for easier work in advance If the inter unit...

Page 11: ...left side left back or left bottom piping Insert the drain hose to this depth so it won t be pulled out of the drain pipe Right bottom piping Right back piping Bind coolant pipe and drain hose togeth...

Page 12: ...our some water into the drain pan to check the water flows smoothly 3 When drain hose requires extension obtain an extension hose commercially available Be sure to thermally insulate the indoor sectio...

Page 13: ...If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air c...

Page 14: ...1101 HT 3P266962 2A M10B169 Two dimensional bar code is a code for manufacturing 00_CV_3P266962 2A fm Page 2 Tuesday September 21 2010 9 05 AM...

Reviews: