Daikin SUPER MULTI NX FTXS15LVJU Installation Manual Download Page 3

2

English

Safety Precautions

 WARNING

• During pump-down, stop the compressor before removing the refrigerant piping.

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, 
causing abnormally high pressure which could lead to equipment damage or and personal injury.

• During installation, attach the refrigerant piping securely before running the compressor.

If the refrigerant pipes are not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, 
causing abnormally high pressure which could lead to equipment damage and personal injury.

• Be sure to install a ground fault circuit interrupter breaker.

Failure to install a ground fault circuit interrupter breaker may result in electrically shocks, or fire personal injury.

 CAUTION

• Do not install the air conditioner where gas leakage would be exposed to open flames.

If the gas leaks and builds up around the unit, it may catch fire.

• Establish drain piping according to the instructions of this manual. 

Inadequate piping may cause water damage.

• Tighten the flare nut according to the specified torque. A torque wrench should be used.

If the flare nut is tightened too much, the flare nut may crack over time and cause refrigerant leakage.

• Do not touch the heat exchanger fins.

Improper handling may result in injury.

• Be very careful about product transportation.

Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.

• Electrical work must be performed in accordance with the NEC/CEC by authorized personnel only.

Accessories

Indoor unit

A  –  M ,

 

Mounting plate

1

 

Remote controller holder

1

 

Tube

1

 

Mounting plate fixing screw 
3/16” × 1” (M4 × 25mm)

9

 

Fixing screw for remote controller 
holder 1/8” × 13/16” (M3 × 20mm)

2

 

Operation manual

1

 

Titanium apatite photocatalytic 
air-purifying filter

2

 

Dry battery AAA. LR03  
(alkaline)

2

 

Installation manual

1

 

Wireless remote controller

1

 

Indoor unit fixing screw  
 3/16” × 1/2” (M4 × 12mm)

2

 

Screw cover

3

Choosing an Installation Site

• Before choosing the installation site, obtain user approval.

1. 

Indoor unit

• The indoor unit should be sited in a place where: 

1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air inlet and air outlet have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the 

remote controller range,

8) the unit is at least 3.5ft (1m) away from any television or radio set (unit may cause interference with the picture or sound),
9) install at the recommended height 6ft (1.8m),

10) no laundry equipment is located in the space.

2. 

Wireless remote controller

1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote control signals are properly 

received by the indoor unit (within 23ft/7m).

A

E

J

B

F

K

C

G

L

D

H

M

01_EN_3P297301-2.indd   2

10/18/2011   2:00:44 PM

Summary of Contents for SUPER MULTI NX FTXS15LVJU

Page 1: ...DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series English Français Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU 00_CV_3P297301 2 indd 1 10 18 2011 10 19 50 AM ...

Page 2: ... or lightning rods because lightning strikes could cause a severe shock hazard resulting in severe injury or death and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death WARNING Installation shall be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment dama...

Page 3: ... for a means of transportation It is dangerous Electrical work must be performed in accordance with the NEC CEC by authorized personnel only Accessories Indoor unit A M Mounting plate 1 Remote controller holder 1 Tube 1 Mounting plate fixing screw 3 16 1 M4 25mm 9 Fixing screw for remote controller holder 1 8 13 16 M3 20mm 2 Operation manual 1 Titanium apatite photocatalytic air purifying filter 2...

Page 4: ...6mm Screw cover 3 pcs M Wrap the thermal insulation pipe with the finishing tape from bottom to top Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty The mounting plate should be installed on a wall which can support the weight of the indoor unit How to attach the indoor unit Ho...

Page 5: ...al method 1 Remove front panel to remove the air filter 2 Remove 6 screws from the front grille 3 In front of the mark of the front grille there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand mark area 3 locations Upper hook Push down Upper hook When there is no work space because the unit is close to ceiling ...

Page 6: ...late electrical cover Main body HA connector S21 HA connector S21 Lay the HA cord as shown in the figure Refrigerant Piping Work With a multi indoor unit install as described in the installation manual supplied with the Multi outdoor unit 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 3 Put the...

Page 7: ... dust and moisture 2 All pipe bends should be as gentle as possible Use a pipe bender for bending Wall If no flare cap is available cover the flare mouth with tape to keep dirt or water out Be sure to place a cap Rain 2 2 Selection of copper and heat insulation materials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0...

Page 8: ... The removed pipe port cover can be kept in the mounting plate pocket Removed pipe port cover A Mounting plate ϕ3 1 8 ϕ80 ϕ3 1 8 ϕ80 Drain hose position 5 1 4 134 unit inch mm Use tape measure as shown Position the end of tape measure at 2 Boring a wall hole and installing wall embedded pipe For walls containing metal frame or metal board be sure to use a wall embedded pipe and wall cover in the f...

Page 9: ...et drain plug No gap Do not apply lubricating oil refrigeration oil when inserting Application of causes deterioration and drain leakage of the plug Insert a hexagonal wrench 3 16 4mm 4 Shape the refrigerant pipes along the pipe path marking on the mounting plate 5 Pass drain hose and refrigerant pipes through the wall hole then set the indoor unit on mounting plate hooks using the markings at the...

Page 10: ...xed to the terminal block 7 In case of connecting to an adapter system run the remote controller cable and attach the S21 Refer to P5 when connecting to an HA system 8 Shape the wires so that the service lid fits securely then close service lid 1 2 3 1 2 3 GR L1L2 Conduit mounting plate Lock nut Back Conduit Terminal block Electrical component box Use the specified wire type Wire retainer Shape wir...

Page 11: ...or section of the extension hose Indoor unit drain hose ϕ5 8 ϕ16mm Extension drain hose Heat insulation tube field supply 4 When connecting a rigid polyvinyl chloride pipe nominal diameter 1 2 inch 13mm directly to the drain hose attached to the indoor unit as with embedded piping work use any commercially available drain socket nominal diameter 1 2 inch 13mm as a joint Drain hose supplied with the...

Page 12: ...he power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Trial operation from remote controller 1 Press ON OFF button to turn on the system 2 Press TEMP button 2 locations and MODE button at the same time 3 Press MODE button twice T will appear on the display to indicate that trial operation mode is selected 4 Trial operation term...

Page 13: ...12 English MEMO 01_EN_3P297301 2 indd 12 10 18 2011 2 00 52 PM ...

Page 14: ...Two dimensional bar code is a code for manufacturing 3P297301 2 M11B120 1111 HT 00_CV_3P297301 2 indd 2 10 18 2011 10 19 50 AM ...

Reviews: