Daikin SUPER MULTI NX FTXS15LVJU Installation Manual Download Page 2

English

English

1

Safety Precautions

• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the precau

-

tions below: they are all important for ensuring safety.

DANGER ..........Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING ........Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.

CAUTION .........Failure to follow any of CAUTION may in some cases result in grave consequences.

• The following safety symbols are used throughout this manual:

Be sure to observe this instruction.

Be sure to establish a ground connection.

Never attempt.

• After completing installation, test the unit to check for installation errors. Give the user adequate instructions con

-

cerning the use and cleaning of the unit according to the Operation Manual.

 DANGER

• Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially 

in basements, and an asphyxiation hazard could occur leading to serious injury or death.

• If the refrigerant gas leaks during installation, ventilate the area immediately.

Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas 
could cause severe injury or death.

• After completing the installation work, check that the refrigerant gas does not leak.

Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas 
could cause severe injury or death.

• Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a 

severe shock hazard resulting in severe injury or death, and to gas pipes because a gas leak could result in an 

explosion which could lead to severe injury or death.

• Safely dispose of the packing materials.

Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear apart and throw away plastic 
packaging bags so that children will not play with them. Children playing with plastic bags face the danger of death by suffocation.

• Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death.
• Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard resulting in 

severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.

 WARNING

• Installation shall be left to the authorized dealer or another trained professional.

Improper installation may cause water leakage, electrical shock, fire, or equipment damage.

• Install the air conditioner according to the instructions given in this manual.

Incomplete installation may cause water leakage, electrical shock, fire or equipment damage.

• Be sure to use the supplied or exact specified installation parts.

Use of other parts may cause the unit to come to fall, water leakage, electrical shock, fire or equipment damage.

• Install the air conditioner on a solid base that is level and can support the weight of the unit.

An inadequate base or incomplete installation may cause injury or equipment damage in the event the unit falls off the base or comes loose.

• Electrical work shall be carried out in accordance with the installation manual and the national, state and local 

electrical wiring codes.

Insufficient capacity or incomplete electrical work may cause electrical shock, fire or equipment damage.

• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. 

Follow all appropriate electrical codes.

• For wiring, use a wire or cable long enough to cover the entire distance with no splices if possible. Do not use an 

extension cord. Do not put other loads on the power supply. Use an only a separate dedicated power circuit.

(Failure to do so may cause abnormal heat, electric shock, fire or equipment damage.)

• Use the specified types of wires for electrical connections between the indoor and outdoor units. Follow all state 

and local electrical codes.

Firmly clamp the inter-unit wire so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal 
overheating, fire or equipment damage.

• After connecting all wires be sure to shape the cables so that they do not put undue stress on the electrical covers, 

panels or terminals.

Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock,fire or equipment damage.

• When installing or relocating the system, be sure to keep the refrigerant circuit free from all substances other than 

the specified refrigerant (R410A), such as air.

(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise which may result in rupture, resulting in injury.)

01_EN_3P297301-2.indd   1

10/18/2011   2:00:44 PM

Summary of Contents for SUPER MULTI NX FTXS15LVJU

Page 1: ...DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series English Français Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU 00_CV_3P297301 2 indd 1 10 18 2011 10 19 50 AM ...

Page 2: ... or lightning rods because lightning strikes could cause a severe shock hazard resulting in severe injury or death and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death WARNING Installation shall be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment dama...

Page 3: ... for a means of transportation It is dangerous Electrical work must be performed in accordance with the NEC CEC by authorized personnel only Accessories Indoor unit A M Mounting plate 1 Remote controller holder 1 Tube 1 Mounting plate fixing screw 3 16 1 M4 25mm 9 Fixing screw for remote controller holder 1 8 13 16 M3 20mm 2 Operation manual 1 Titanium apatite photocatalytic air purifying filter 2...

Page 4: ...6mm Screw cover 3 pcs M Wrap the thermal insulation pipe with the finishing tape from bottom to top Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty The mounting plate should be installed on a wall which can support the weight of the indoor unit How to attach the indoor unit Ho...

Page 5: ...al method 1 Remove front panel to remove the air filter 2 Remove 6 screws from the front grille 3 In front of the mark of the front grille there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand mark area 3 locations Upper hook Push down Upper hook When there is no work space because the unit is close to ceiling ...

Page 6: ...late electrical cover Main body HA connector S21 HA connector S21 Lay the HA cord as shown in the figure Refrigerant Piping Work With a multi indoor unit install as described in the installation manual supplied with the Multi outdoor unit 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 3 Put the...

Page 7: ... dust and moisture 2 All pipe bends should be as gentle as possible Use a pipe bender for bending Wall If no flare cap is available cover the flare mouth with tape to keep dirt or water out Be sure to place a cap Rain 2 2 Selection of copper and heat insulation materials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0...

Page 8: ... The removed pipe port cover can be kept in the mounting plate pocket Removed pipe port cover A Mounting plate ϕ3 1 8 ϕ80 ϕ3 1 8 ϕ80 Drain hose position 5 1 4 134 unit inch mm Use tape measure as shown Position the end of tape measure at 2 Boring a wall hole and installing wall embedded pipe For walls containing metal frame or metal board be sure to use a wall embedded pipe and wall cover in the f...

Page 9: ...et drain plug No gap Do not apply lubricating oil refrigeration oil when inserting Application of causes deterioration and drain leakage of the plug Insert a hexagonal wrench 3 16 4mm 4 Shape the refrigerant pipes along the pipe path marking on the mounting plate 5 Pass drain hose and refrigerant pipes through the wall hole then set the indoor unit on mounting plate hooks using the markings at the...

Page 10: ...xed to the terminal block 7 In case of connecting to an adapter system run the remote controller cable and attach the S21 Refer to P5 when connecting to an HA system 8 Shape the wires so that the service lid fits securely then close service lid 1 2 3 1 2 3 GR L1L2 Conduit mounting plate Lock nut Back Conduit Terminal block Electrical component box Use the specified wire type Wire retainer Shape wir...

Page 11: ...or section of the extension hose Indoor unit drain hose ϕ5 8 ϕ16mm Extension drain hose Heat insulation tube field supply 4 When connecting a rigid polyvinyl chloride pipe nominal diameter 1 2 inch 13mm directly to the drain hose attached to the indoor unit as with embedded piping work use any commercially available drain socket nominal diameter 1 2 inch 13mm as a joint Drain hose supplied with the...

Page 12: ...he power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Trial operation from remote controller 1 Press ON OFF button to turn on the system 2 Press TEMP button 2 locations and MODE button at the same time 3 Press MODE button twice T will appear on the display to indicate that trial operation mode is selected 4 Trial operation term...

Page 13: ...12 English MEMO 01_EN_3P297301 2 indd 12 10 18 2011 2 00 52 PM ...

Page 14: ...Two dimensional bar code is a code for manufacturing 3P297301 2 M11B120 1111 HT 00_CV_3P297301 2 indd 2 10 18 2011 10 19 50 AM ...

Reviews: