SiBE121135
Outdoor Unit: 80/90 Class
Removal Procedure
385
10
Disconnect the
connector for the
overload protector
[S40].
11
The wire harness for
the compressor is
attached to the partition
plate (1) by the clamp.
12
Pull out the clamp with
pliers.
Step
Procedure
Points
[S40]
(R10539)
Clamp
(R12904)
Partition
plate
Clamp
(R6423)